EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Whole‐liver flip‐angle shimming at 7 T using parallel‐transmit k T ‐point pulses and Fourier phase‐encoded DREAM B1+ mapping

Bobby A Runderkamp iD, Thomas Roos iD, Wietske van der Zwaag iD, Gustav J Strijkers iD, Matthan W A Caan iD, Aart J Nederveen iD

Magnetic Resonance in Medicine · 2024-01 · 91 (1) · 75-90

DOI: 10.1002/mrm.29819 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 05.10.2023. Verfasst von Bobby A Runderkamp und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, the Netherlands. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Image Interpretation, Computer-Assisted. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 78 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To obtain homogeneous signal throughout the human liver at 7 T. Flip angle (FA) shimming in 7T whole‐liver imaging was performed through parallel‐transmit k T ‐point pulses based on subject‐specific multichannel absolute maps from Fourier phase‐encoded dual refocusing echo acquisition mode (PE‐DREAM).

Methods

The optimal number of Fourier phase‐encoding steps for PE‐DREAM mapping was determined for a 7T eight‐channel parallel‐transmission system. FA shimming experiments were performed in the liver of 7 healthy subjects with varying body mass index. In these subjects, first shimming and Fourier PE‐DREAM mapping were performed. Subsequently, three small‐flip‐angle 3D gradient‐echo scans were acquired, comparing a circularly polarized (CP) mode, a phase shim, and a k T ‐point pulse. Resulting homogeneity was assessed and compared with estimated FA maps and distributions.

Results

Fourier PE‐DREAM with 13 phase‐encoding steps resulted in a good tradeoff between accuracy and scan time. Lower coefficient of variation values (average [min‐max] across subjects) of the estimated FA in the volume of interest were observed using k T ‐points (7.4 [6.6%–8.0%]), compared with phase shimming (18.8 [12.9%–23.4%], p < 0.001) and CP (43.2 [39.4%–47.1%], p < 0.001). k T ‐points delivered whole‐liver images with the nominal FA and the highest degree of homogeneity. CP and phase shimming resulted in either inaccurate or imprecise FA distributions. Here, locations having suboptimal FA in the estimated FA maps corresponded to liver areas suffering from inconsistent signal intensity and T 1 ‐weighting in the gradient‐echo scans.

Conclusion

Homogeneous whole‐liver 3D gradient‐echo acquisitions at 7 T can be obtained with eight‐channel k T ‐point pulses calculated based on subject‐specific multichannel absolute Fourier PE‐DREAM maps.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingImage Interpretation, Computer-AssistedHumansAlgorithmsRadio WavesLiverBrain

Stichwörter der Autor:innen

7 TFourier phase-encoded DREAMflip-angle shimmingkT-pointsliverparallel transmission

Autor:innen und Institutionen

  • Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, the Netherlands.
  • Spinoza Centre for Neuroimaging, Royal Netherlands Academy for Arts and Sciences (KNAW), Amsterdam, the Netherlands.
  • High-Field Research Group, University Medical Center Utrecht, Utrecht, The Netherlands.
  • Computational and Cognitive Neuroscience and Neuroimaging, Netherlands Institute for Neuroscience, KNAW, Amsterdam, the Netherlands.
  • Department of Biomedical Engineering and Physics, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam Cardiovascular Sciences, Amsterdam, the Netherlands.

ORCID-Profile: Bobby A Runderkamp, Thomas Roos, Wietske van der Zwaag, Gustav J Strijkers, Matthan W A Caan, Aart J Nederveen

Zitieren

APA

Runderkamp, B. A., Roos, T., van der Zwaag, W., Strijkers, G. J., Caan, M. W. A., & Nederveen, A. J. (2024). Whole‐liver flip‐angle shimming at 7 T using parallel‐transmit k T ‐point pulses and Fourier phase‐encoded DREAM B1+ mapping. Magnetic Resonance in Medicine, 91(1), 75-90. https://doi.org/10.1002/mrm.29819

Vancouver

Runderkamp BA, Roos T, van der Zwaag W, Strijkers GJ, Caan MWA, Nederveen AJ. Whole‐liver flip‐angle shimming at 7 T using parallel‐transmit k T ‐point pulses and Fourier phase‐encoded DREAM B1+ mapping. Magnetic Resonance in Medicine. 2024;91(1):75-90. doi:10.1002/mrm.29819

BibTeX
@article{Runderkamp2024,
  author = {Runderkamp, Bobby A and Roos, Thomas and van der Zwaag, Wietske and Strijkers, Gustav J and Caan, Matthan W A and Nederveen, Aart J},
  title = {Whole‐liver flip‐angle shimming at 7 T using parallel‐transmit k T ‐point pulses and Fourier phase‐encoded DREAM B1+ mapping},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  volume = {91},
  number = {1},
  pages = {75--90},
  doi = {10.1002/mrm.29819}
}
Kostenlos starten →