Optimal Transmission Performance of Quadrature Wireless Resonators at 3 T
Magnetic Resonance in Medicine · 2027-01 · 97 (1) · 403-413
DOI: 10.1002/mrm.70610 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 24.09.2026. Verfasst von Leila Sharipova und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Physics and Engineering, ITMO University, Saint Petersburg, Russian Federation. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Transducers, Wireless Technology, Breast. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Russian Federation project for Science and Universities, Amidex.
Abstract (Originalsprache)
Purpose
To demonstrate a method for optimizing the efficiency of wireless resonators using tailored excitation from a dual‐transmit birdcage coil (BC), and to present the design and experimental investigation of a quadrature resonator for 3 T breast MRI application.
Methods
A double‐mode quadrature resonator was designed to enhance both orthogonal components of the field in a 3 T BC. Flip‐angle maps measurements were performed on phantom to validate the predicted transmit efficiency gains. Numerical simulations were performed on a human voxel model to demonstrate the ability to optimize the field and SAR metrics.
Results
Experiments confirmed that each linear polarization was enhanced by the resonator, yielding a 4.5‐fold improvement in the transmit efficiency compared with the reference BC under conventional circularly polarized (CP) excitation. The optimal excitation was derived and validated experimentally, leading to an additional 2% increase in transmit efficiency. Simulations revealed that the resonator provided a 5.9‐fold (left breast) and 5.2‐fold (right breast) improvement in SAR efficiency under conventional CP excitation. Tailored excitations further increased SAR efficiency by 15% (left breast) and 31% (right breast), approaching a 7‐fold improvement compared to the reference BC.
Conclusion
A double‐mode quadrature resonator was demonstrated for 3 T MRI. Combined with dual‐transmit BC, it enabled focusing and significantly improved transmit and SAR efficiency. Our analytical model allowed the derivation of tailored BC excitation to approach the theoretical performance limit of wireless resonators.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Physics and Engineering, ITMO University, Saint Petersburg, Russian Federation.
- Aix-Marseille Université, CNRS, Centre de Résonance Magnétique Biologique et Médicale, Marseille, France.
- Aix-Marseille Université, CNRS, Centrale Med, Institut Fresnel, Marseille, France.
ORCID-Profile: Dmitrii Tikhonenko, Alena Shchelokova, Marc Dubois
Förderung
- Russian Federation project for Science and Universities
- Amidex
Zitieren
APA
Sharipova, L., Tikhonenko, D., Vilmen, C., Bendahan, D., Enoch, S., Abdeddaim, R., Shchelokova, A., & Dubois, M. (2027). Optimal Transmission Performance of Quadrature Wireless Resonators at 3 T. Magnetic Resonance in Medicine, 97(1), 403-413. https://doi.org/10.1002/mrm.70610
Vancouver
Sharipova L, Tikhonenko D, Vilmen C, Bendahan D, Enoch S, Abdeddaim R, et al. Optimal Transmission Performance of Quadrature Wireless Resonators at 3 T. Magnetic Resonance in Medicine. 2027;97(1):403-413. doi:10.1002/mrm.70610
BibTeX
@article{Sharipova2027,
author = {Sharipova, Leila and Tikhonenko, Dmitrii and Vilmen, Christophe and Bendahan, David and Enoch, Stefan and Abdeddaim, Redha and Shchelokova, Alena and Dubois, Marc},
title = {Optimal Transmission Performance of Quadrature Wireless Resonators at 3 T},
journal = {Magnetic Resonance in Medicine},
year = {2027},
volume = {97},
number = {1},
pages = {403--413},
doi = {10.1002/mrm.70610}
}
EUVIMED