Transient shear wave elastometry using a portable magnetic resonance sensor
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30444 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von William Selby und 2 weiteren Autor:innen. Beteiligte Einrichtung: MRI Research Centre, Physics, University of New Brunswick, Fredericton, New Brunswick, Canada. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques, Transducers, Magnetic Resonance Imaging. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: Natural Sciences and Engineering Research Council of Canada, New Brunswick Innovation Foundation.
Abstract (Originalsprache)
Purpose
Magnetic resonance elastography (MRE) provides detailed maps of tissue stiffness, helping to diagnose various health conditions, but requires the use of expensive clinical MRI scanners. Our approach utilizes compact, cost‐effective portable MR sensors that offer bulk characterization of material properties in a region of interest close to the surface (within 1–2 cm). This accessible instrument could enable routine monitoring and prevention of diseases not readily evaluated with conventional tools.
Methods
The method was tested on tissue‐mimicking phantoms with varying stiffness. The gels were excited with acoustic pulses (one cycle of a sinusoidal waveform) at a fixed distance from the MR sensor. A series of delays between acoustic excitation and MR signal detection allowed time for the pulse to travel to the sensitive region.
Results
The “arrival time” of the shear wave, determined by the time‐dependent MR signal response, was used to calculate the shear wave speed. MR measurements of shear wave speed were compared with optical sensor measurements and manufacturer‐tabulated values, aligning with expected relative differences between samples.
Conclusion
A portable MR‐based transient elastometry technique for measuring tissue elasticity was developed and demonstrated on tissue‐mimicking phantoms. Future improvements include using a new portable magnet to investigate depth‐dependent changes in elasticity in stratified samples and integrating MR relaxation and diffusion measurements for comprehensive tissue analysis. This approach can complement conventional MRE in applications where a portable, affordable, and localized assessment of tissue stiffness is required.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- MRI Research Centre, Physics, University of New Brunswick, Fredericton, New Brunswick, Canada.
- Mechanical Engineering, University of New Brunswick, Fredericton, New Brunswick, Canada.
ORCID-Profile: William Selby
Förderung
- Natural Sciences and Engineering Research Council of Canada
- New Brunswick Innovation Foundation
Zitieren
APA
Selby, W., Garland, P., & Mastikhin, I. (2025). Transient shear wave elastometry using a portable magnetic resonance sensor. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30444
Vancouver
Selby W, Garland P, Mastikhin I. Transient shear wave elastometry using a portable magnetic resonance sensor. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30444
BibTeX
@article{Selby2025,
author = {Selby, William and Garland, Phil and Mastikhin, Igor},
title = {Transient shear wave elastometry using a portable magnetic resonance sensor},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30444}
}
EUVIMED