Design of an In Vivo‐Like Phantom for Quantitative Body CEST MRI
Magnetic Resonance in Medicine · 2027-01 · 97 (1) · 454-463
DOI: 10.1002/mrm.70585 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 09.09.2026. Verfasst von Petr Menshchikov und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany. Hauptthemen laut MEDLINE: Phantoms, Imaging, Magnetic Resonance Imaging, Adipose Tissue. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Helmholtz Initiative and Networking Fund: MIB2 - Molecular MR Imaging of the Brain and the Body, German Cancer Consortium (DKTK) Seed Funding: MAMMACARE - Towards Molecular MR Mammography for Cancer Care, Deutschen Konsortium für Translationale Krebsforschung.
Abstract (Originalsprache)
Purpose
To design and validate a reproducible in vivo‐like fat‐containing CEST phantom that enables robust quantitative CEST MRI for body applications by providing physiologically realistic relaxation properties, relevant endogenous CEST contrasts (amide, guanidino, rNOE, and semi‐solid MT), and a controlled fat component.
Methods
An agar‐based water‐fat CEST phantom was designed using agar, gelatin, and bovine serum albumin, with adjustable fat fraction (FF) achieved through stable water‐fat emulsions. Phantom composition was tuned to reproduce tissue‐relevant T 1 and T 2 relaxation times and physiological pH. The accuracy and temporal stability of FFs and CEST contrasts were assessed over a 3‐month period. Low‐power CEST MRI at 7T was performed to quantify amide, guanidino, and rNOE contrasts using the inverse metric MTR Rex , and their concentration dependence and temporal stability were evaluated.
Results
The proposed phantom‐generated Z‐spectra closely resembled in vivo body CEST measurements and reproduced major endogenous CEST and semi‐solid MT effects with controllable contrast levels. Stable and reproducible FF values were achieved for FFs up to 50% over the investigated 3‐month period, covering the clinically relevant range for most body tissues. Quantitative CEST metrics demonstrated linear concentration dependence and good temporal stability.
Conclusion
An in vivo‐like, fat‐containing CEST phantom was developed and validated as a reproducible and physiologically relevant reference standard for quantitative body CEST MRI. By enabling controlled investigation of fat‐induced effects on CEST contrast quantification, this phantom supports the standardized validation of fat suppression and correction strategies and facilitates methodological development and cross‐study comparability in body CEST imaging.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany.
- German Cancer Consortium (DKTK), Core Center Heidelberg, Heidelberg, Germany.
- Faculty of Physics and Astronomy, Heidelberg University, Heidelberg, Germany.
- Faculty of Medicine, Heidelberg University, Heidelberg, Germany.
- Department of Cardiology, Pulmonology Diseases and Vascular Medicine, Medical Faculty, Heinrich-Heine-University, Düsseldorf, Germany.
ORCID-Profile: Petr Menshchikov, Neele Kempa, Andreas Korzowski, Philip S Boyd
Förderung
- Helmholtz Initiative and Networking Fund: MIB2 - Molecular MR Imaging of the Brain and the Body
- German Cancer Consortium (DKTK) Seed Funding: MAMMACARE - Towards Molecular MR Mammography for Cancer Care
- Deutschen Konsortium für Translationale Krebsforschung
Zitieren
APA
Menshchikov, P., Bulanov, P., Kempa, N., Ladd, M. E., Korzowski, A., & Boyd, P. S. (2027). Design of an In Vivo‐Like Phantom for Quantitative Body CEST MRI. Magnetic Resonance in Medicine, 97(1), 454-463. https://doi.org/10.1002/mrm.70585
Vancouver
Menshchikov P, Bulanov P, Kempa N, Ladd ME, Korzowski A, Boyd PS. Design of an In Vivo‐Like Phantom for Quantitative Body CEST MRI. Magnetic Resonance in Medicine. 2027;97(1):454-463. doi:10.1002/mrm.70585
BibTeX
@article{Menshchikov2027,
author = {Menshchikov, Petr and Bulanov, Petr and Kempa, Neele and Ladd, Mark E and Korzowski, Andreas and Boyd, Philip S},
title = {Design of an In Vivo‐Like Phantom for Quantitative Body CEST MRI},
journal = {Magnetic Resonance in Medicine},
year = {2027},
volume = {97},
number = {1},
pages = {454--463},
doi = {10.1002/mrm.70585}
}
EUVIMED