EUVIMEDSkopri EUVIMED
Open access · CC BY 4.0

High Dynamic Range Turbo‐ FLASH B1 Mapping for Characterizing Multi‐Transmit Multi‐Receive RF Arrays, Validated at 7 T and 11.7 T

Natalia Dudysheva iD, Franck Mauconduit iD, Michel Luong iD, Alexis Amadon iD, Nicolas Boulant iD, Vincent Gras iD

Magnetic Resonance in Medicine · 2027-01 · 97 (1) · 240-249

DOI: 10.1002/mrm.70569 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, published online on 2026-09-17. Written by Natalia Dudysheva and 5 co-authors. Institution: Université Paris-Saclay, CEA, CNRS, BAOBAB, NeuroSpin, Gif sur Yvette, France. Major MEDLINE topics: Magnetic Resonance Imaging, Image Processing, Computer-Assisted. 36 references. The full text is freely available (open access, CC BY 4.0). Funded by: Agence Nationale de la Recherche.

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Purpose

Transmit (B 1 + ) and receive (B 1 − ) sensitivities of parallel‐transmit/receive RF array are a prerequisite for modern ultra‐high‐field MRI. Their accurate mapping remains challenging for coils with high transmit dynamic range, particularly in regions with low combined‐mode B 1 + magnitude, where standard reconstruction is impaired by noise. This work presents a new B 1 + and B 1 − model‐based fitting approach for interferometric presaturated TurboFLASH (satTFL) data. With an optimized acquisition scheme, this method improves B 1 + /B 1 − mapping accuracy.

Methods

Voxel‐wise B 1 + and B 1 − are expressed as the product of a complex unit‐norm vector (phasor) and a scalar (efficiency). Phasors are estimated through singular value decomposition of satTFL signals, and efficiencies are recovered with fitting to the signal equation. This method was evaluated in phantom simulations for 7 T and 11.7 T 8Tx/32Rx RF arrays and compared with standard approaches. As it supports a variable number of pre‐saturated scans, different interferometric schemes were optimized for B 1 + accuracy. Finally, schemes yielding acceptable B 1 + error with minimal acquisition time were tested in vitro at 7 T and 11.7 T and in vivo at 7 T.

Results

The proposed method provided lower median B 1 + and B 1 − errors than conventional satTFL methods and fewer outliers; the number of voxels with error > 30% is reduced from several dozens to zero. In vitro results were consistent with the simulations, and in vivo maps demonstrated good quality.

Conclusion

The proposed method improves B 1 + and B 1 − mapping robustness to noise and enables more flexible satTFL acquisition scheme, allowing better trade‐offs between accuracy and scan time.

Subjects

MeSH terms (MEDLINE)

Magnetic Resonance ImagingImage Processing, Computer-AssistedPhantoms, ImagingReproducibility of ResultsAlgorithmsRadio WavesSensitivity and SpecificityImage EnhancementEquipment DesignSignal Processing, Computer-AssistedComputer SimulationHumansImage Interpretation, Computer-Assisted

Author keywords

B1 mappingRF arrayparallel transmissionultra‐high field MRI

Authors and institutions

  • Université Paris-Saclay, CEA, CNRS, BAOBAB, NeuroSpin, Gif sur Yvette, France.
  • Université Paris-Saclay, CEA, DRF, IRFU, Gif sur Yvette, France.

ORCID profiles: Natalia Dudysheva, Franck Mauconduit, Michel Luong, Alexis Amadon, Nicolas Boulant, Vincent Gras

Funding

  • Agence Nationale de la Recherche

Cite

APA

Dudysheva, N., Mauconduit, F., Luong, M., Amadon, A., Boulant, N., & Gras, V. (2027). High Dynamic Range Turbo‐ FLASH B1 Mapping for Characterizing Multi‐Transmit Multi‐Receive RF Arrays, Validated at 7 T and 11.7 T. Magnetic Resonance in Medicine, 97(1), 240-249. https://doi.org/10.1002/mrm.70569

Vancouver

Dudysheva N, Mauconduit F, Luong M, Amadon A, Boulant N, Gras V. High Dynamic Range Turbo‐ FLASH B1 Mapping for Characterizing Multi‐Transmit Multi‐Receive RF Arrays, Validated at 7 T and 11.7 T. Magnetic Resonance in Medicine. 2027;97(1):240-249. doi:10.1002/mrm.70569

BibTeX
@article{Dudysheva2027,
  author = {Dudysheva, Natalia and Mauconduit, Franck and Luong, Michel and Amadon, Alexis and Boulant, Nicolas and Gras, Vincent},
  title = {High Dynamic Range Turbo‐ FLASH B1 Mapping for Characterizing Multi‐Transmit Multi‐Receive RF Arrays, Validated at 7 T and 11.7 T},
  journal = {Magnetic Resonance in Medicine},
  year = {2027},
  volume = {97},
  number = {1},
  pages = {240--249},
  doi = {10.1002/mrm.70569}
}
Start for free →