High Dynamic Range Turbo‐ FLASH B1 Mapping for Characterizing Multi‐Transmit Multi‐Receive RF Arrays, Validated at 7 T and 11.7 T
Magnetic Resonance in Medicine · 2027-01 · 97 (1) · 240-249
DOI: 10.1002/mrm.70569 ↗At a glance
Journal article in Magnetic Resonance in Medicine, published online on 2026-09-17. Written by Natalia Dudysheva and 5 co-authors. Institution: Université Paris-Saclay, CEA, CNRS, BAOBAB, NeuroSpin, Gif sur Yvette, France. Major MEDLINE topics: Magnetic Resonance Imaging, Image Processing, Computer-Assisted. 36 references. The full text is freely available (open access, CC BY 4.0). Funded by: Agence Nationale de la Recherche.
Abstract (original language)
Purpose
Transmit (B 1 + ) and receive (B 1 − ) sensitivities of parallel‐transmit/receive RF array are a prerequisite for modern ultra‐high‐field MRI. Their accurate mapping remains challenging for coils with high transmit dynamic range, particularly in regions with low combined‐mode B 1 + magnitude, where standard reconstruction is impaired by noise. This work presents a new B 1 + and B 1 − model‐based fitting approach for interferometric presaturated TurboFLASH (satTFL) data. With an optimized acquisition scheme, this method improves B 1 + /B 1 − mapping accuracy.
Methods
Voxel‐wise B 1 + and B 1 − are expressed as the product of a complex unit‐norm vector (phasor) and a scalar (efficiency). Phasors are estimated through singular value decomposition of satTFL signals, and efficiencies are recovered with fitting to the signal equation. This method was evaluated in phantom simulations for 7 T and 11.7 T 8Tx/32Rx RF arrays and compared with standard approaches. As it supports a variable number of pre‐saturated scans, different interferometric schemes were optimized for B 1 + accuracy. Finally, schemes yielding acceptable B 1 + error with minimal acquisition time were tested in vitro at 7 T and 11.7 T and in vivo at 7 T.
Results
The proposed method provided lower median B 1 + and B 1 − errors than conventional satTFL methods and fewer outliers; the number of voxels with error > 30% is reduced from several dozens to zero. In vitro results were consistent with the simulations, and in vivo maps demonstrated good quality.
Conclusion
The proposed method improves B 1 + and B 1 − mapping robustness to noise and enables more flexible satTFL acquisition scheme, allowing better trade‐offs between accuracy and scan time.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Université Paris-Saclay, CEA, CNRS, BAOBAB, NeuroSpin, Gif sur Yvette, France.
- Université Paris-Saclay, CEA, DRF, IRFU, Gif sur Yvette, France.
ORCID profiles: Natalia Dudysheva, Franck Mauconduit, Michel Luong, Alexis Amadon, Nicolas Boulant, Vincent Gras
Funding
- Agence Nationale de la Recherche
Cite
APA
Dudysheva, N., Mauconduit, F., Luong, M., Amadon, A., Boulant, N., & Gras, V. (2027). High Dynamic Range Turbo‐ FLASH B1 Mapping for Characterizing Multi‐Transmit Multi‐Receive RF Arrays, Validated at 7 T and 11.7 T. Magnetic Resonance in Medicine, 97(1), 240-249. https://doi.org/10.1002/mrm.70569
Vancouver
Dudysheva N, Mauconduit F, Luong M, Amadon A, Boulant N, Gras V. High Dynamic Range Turbo‐ FLASH B1 Mapping for Characterizing Multi‐Transmit Multi‐Receive RF Arrays, Validated at 7 T and 11.7 T. Magnetic Resonance in Medicine. 2027;97(1):240-249. doi:10.1002/mrm.70569
BibTeX
@article{Dudysheva2027,
author = {Dudysheva, Natalia and Mauconduit, Franck and Luong, Michel and Amadon, Alexis and Boulant, Nicolas and Gras, Vincent},
title = {High Dynamic Range Turbo‐ FLASH B1 Mapping for Characterizing Multi‐Transmit Multi‐Receive RF Arrays, Validated at 7 T and 11.7 T},
journal = {Magnetic Resonance in Medicine},
year = {2027},
volume = {97},
number = {1},
pages = {240--249},
doi = {10.1002/mrm.70569}
}
EUVIMED