Pure steady-state CEST
Magnetic Resonance Imaging · 2025
DOI: 10.1016/j.mri.2025.110506 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2025. Verfasst von Johannes Hammacher und 2 weiteren Autor:innen. Beteiligte Einrichtung: Physikalisch-Technische Bundesanstalt (PTB), Berlin and Braunschweig, Germany. Electronic address: johannes.hammacher@ptb.de. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Brain, Image Processing, Computer-Assisted. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Metrology Programme for Innovation and Research, Horizon 2020 Framework Programme, Deutsche Forschungsgemeinschaft.
Abstract (Originalsprache)
A novel steady-state CEST sequence design, based on the underlying physical model of longitudinal magnetization development during CEST saturation and data acquisition is presented and validated in-silico, in vitro and in vivo. This design ensures consistent data acquisition in the pure CEST steady-state, leading to high MTRasym scores and image quality, both in vitro and in vivo, when compared to contemporary sequential and steady-state CEST sequences. PURPOSE: The aim of this study was to enhance CEST sequences by utilizing the pure CEST steady-state in order to deliver higher CEST effects and better sensitivity. METHODS: A novel CEST saturation/readout scheme was designed, tested in numerical simulations and subsequently validated in vitro and in vivo. RESULTS: The novel Multi-2D Spiral pure steady-state CEST sequence showed to deliver advantageous sensitivity and efficacy. CONCLUSION: Constraining image acquisition to the pure CEST steady-state showed promising results in first in vitro and in vivo experiments.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Physikalisch-Technische Bundesanstalt (PTB), Berlin and Braunschweig, Germany. Electronic address: johannes.hammacher@ptb.de.
- Physikalisch-Technische Bundesanstalt (PTB), Berlin and Braunschweig, Germany.
Förderung
- European Metrology Programme for Innovation and Research
- Horizon 2020 Framework Programme
- Deutsche Forschungsgemeinschaft
Zitieren
APA
Hammacher, J., Kolbitsch, C., & Schuenke, P. (2025). Pure steady-state CEST. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2025.110506
Vancouver
Hammacher J, Kolbitsch C, Schuenke P. Pure steady-state CEST. Magnetic Resonance Imaging. 2025. doi:10.1016/j.mri.2025.110506
BibTeX
@article{Hammacher2025,
author = {Hammacher, Johannes and Kolbitsch, Christoph and Schuenke, Patrick},
title = {Pure steady-state CEST},
journal = {Magnetic Resonance Imaging},
year = {2025},
doi = {10.1016/j.mri.2025.110506}
}
EUVIMED