Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 18.06.2026. Verfasst von Jose Raul Velasquez Vides und 16 weiteren Autor:innen. Beteiligte Einrichtung: Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin Ultrahigh Field Facility (B.U.F.F.), Berlin, Germany. Hauptthemen laut MEDLINE: Multiple Sclerosis, Echo-Planar Imaging, Image Processing, Computer-Assisted, Brain. Die Arbeit nennt 126 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIH HHS, NICHD NIH HHS, Deutsche Forschungsgemeinschaft.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To demonstrate the synergy of undersampled radial 2in1‐RARE‐EPI acquisition and nonlinear model‐based reconstruction for accelerated and simultaneous T 2 , T 2 *, and R 2 ′ mapping in brains of patients with multiple sclerosis (MS).

Methods

2in1‐RARE‐EPI combines a RARE module with an EPI module to capture T 2 and T 2 * information. Nonlinear model‐based reconstruction was applied to estimate T 2 , T 2 * maps directly from undersampled k ‐space data. A retrospective undersampling experiment was conducted to compare nonlinear model‐based and parallel imaging compressed sensing (PICS) reconstruction. The proposed approach was validated and compared to reference methods multiecho spin‐echo ( T 2 , MSE) and multiecho gradient‐echo ( T 2 *, MGRE) in a phantom, healthy subjects, and MS patients.

Results

2in1‐RARE‐EPI together with nonlinear model‐based reconstruction enabled T 2 , T 2 *, and R 2 ′ mapping with 7.5‐fold scan‐time acceleration relative to the references, while addressing key limitations of reference techniques, including long acquisition times, misregistration, motion and off‐resonance sensitivity, and the need for calibration scans. Phantom and in vivo validation showed that the parametric maps obtained with this approach were in agreement with the reference methods. Compared with PICS, nonlinear model‐based reconstruction showed more consistent spatial detail and accuracy at higher acceleration factors. The proposed method detected small focal lesions in T 2 , T 2 *, and R 2 ′ maps of MS patients and enabled visualization of the central vein sign.

Conclusion

Scan time reduction facilitated by nonlinear model‐based reconstruction of 2in1‐RARE‐EPI provides a technical foundation for enhanced patient compliance, and is a fundamental precursor for broader clinical studies on the potential of T 2 , T 2 *, and R 2 ′ as imaging biomarkers.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Multiple SclerosisEcho-Planar ImagingImage Processing, Computer-AssistedBrainMagnetic Resonance ImagingHumansPhantoms, ImagingNonlinear DynamicsAlgorithmsRetrospective StudiesAdultFemaleReproducibility of ResultsImage Interpretation, Computer-AssistedMale

Stichwörter der Autor:innen

R2′ mappingcentral vein signmultiple sclerosisnonlinear model‐based reconstructionquantitative multiparametric MRIsimultaneous T2 and T2* mapping

Autor:innen und Institutionen

  • Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin Ultrahigh Field Facility (B.U.F.F.), Berlin, Germany.
  • Institute for Medical Engineering, Otto-von-Guericke University, Magdeburg, Germany.
  • Department of Physics, Humboldt Universität zu Berlin, Berlin, Germany.
  • Resonance Research Inc., Billerica, Massachusetts, USA.
  • Department of Biomedical Magnetic Resonance, Otto-von-Guericke University, Magdeburg, Germany.
  • German Center for Neurodegenerative Diseases (DZNE), Magdeburg, Germany.

ORCID-Profile: Jose Raul Velasquez Vides, Carl J J Herrmann, Thomas Gladytz, Hendrik Mattern, Xiaoqing Wang, Jason M Millward, Shahriar Shalikar, Igor Fabian Tellez Ceja, Beate Endemann, Sonia Waiczies, Joseph Kuchling, Friedemann Paul, Georg Rose, Min-Chi Ku, Thoralf Niendorf

Förderung

  • NIH HHS
  • NICHD NIH HHS
  • Deutsche Forschungsgemeinschaft
  • German-Israeli Foundation for Scientific Research and Development
  • MDC-Weizmann Helmholtz International Research School for Imaging and Data Science from the NAno to the MEso
  • NIBIB NIH HHS
  • National Institutes of Health

Zitieren

APA

Velasquez Vides, J. R., Herrmann, C. J. J., Gladytz, T., Hetherington, H. P., Mattern, H., Wang, X., Millward, J. M., Shalikar, S., Tellez Ceja, I. F., Endemann, B., Waiczies, S., Kuchling, J., Paul, F., Rose, G., Ku, M. C., Schmitt, F., & Niendorf, T. (2026). Simultaneous T 2 , T 2 *, and R 2 ′ Mapping for Multiple Sclerosis Using Nonlinear Model‐Based Reconstruction of Undersampled Radial RARE ‐ EPI MRI. Magnetic Resonance in Medicine, 96(4), 1872-1892. https://doi.org/10.1002/mrm.70465

Vancouver

Velasquez Vides JR, Herrmann CJJ, Gladytz T, Hetherington HP, Mattern H, Wang X, et al. Simultaneous T 2 , T 2 *, and R 2 ′ Mapping for Multiple Sclerosis Using Nonlinear Model‐Based Reconstruction of Undersampled Radial RARE ‐ EPI MRI. Magnetic Resonance in Medicine. 2026;96(4):1872-1892. doi:10.1002/mrm.70465

BibTeX
@article{VelasquezVides2026,
  author = {Velasquez Vides, Jose Raul and Herrmann, Carl J J and Gladytz, Thomas and Hetherington, Hoby P and Mattern, Hendrik and Wang, Xiaoqing and Millward, Jason M and Shalikar, Shahriar and Tellez Ceja, Igor Fabian and Endemann, Beate and Waiczies, Sonia and Kuchling, Joseph and Paul, Friedemann and Rose, Georg and Ku, Min-Chi and Schmitt, Franz and Niendorf, Thoralf},
  title = {Simultaneous T 2 , T 2 *, and R 2 ′ Mapping for Multiple Sclerosis Using Nonlinear Model‐Based Reconstruction of Undersampled Radial RARE ‐ EPI MRI},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  volume = {96},
  number = {4},
  pages = {1872--1892},
  doi = {10.1002/mrm.70465}
}
Kostenlos starten →