Dynamic field mapping and distortion correction using single‐shot blip‐rewound EPI and joint multi‐echo reconstruction
Magnetic Resonance in Medicine · 2024
DOI: 10.1002/mrm.30038 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Wenchuan Wu. Beteiligte Einrichtung: Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK. Hauptthemen laut MEDLINE: Algorithms, Phantoms, Imaging, Echo-Planar Imaging. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Wellcome Trust, Department of Health, Royal Academy of Engineering.
Abstract (Originalsprache)
Purpose
To develop a method for dynamic mapping and distortion correction.
Methods
A blip‐rewound EPI trajectory was developed to acquire multiple 2D EPI images in a single readout with an interleaved order, which allows a short TE difference. A joint multi‐echo reconstruction was utilized to exploit the shared information between EPI images. The reconstructed images from each readout are combined to produce a final magnitude image. A map is calculated from the phase of these images for distortion correction. The efficacy of the proposed method is assessed with phantom and in vivo experiments. The performance of the proposed method in the presence of subject motion is also investigated.
Results
Compared to conventional multi‐echo EPI, the proposed method allows dynamic mapping at matched resolution with a much shorter TR. Phantom and in vivo results show that the proposed method can provide a comparable magnitude image as conventional single‐shot EPI. The maps calculated from the proposed method are consistent with conventional multi‐echo EPI in the phantom experiment. For in vivo experiments, the proposed method provides a more accurate estimation of than conventional multi‐echo EPI, which is prone to phase wrapping problems due to the long TE difference. In‐vivo scan with subject motion shows the proposed dynamic field mapping method can improve the temporal stability of EPI time series compared to gradient echo (GRE) based static field mapping.
Conclusion
The proposed method allows accurate dynamic mapping for robust distortion correction without compromising spatial or temporal resolution.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK.
ORCID-Profile: Wenchuan Wu
Förderung
- Wellcome Trust
- Department of Health
- Royal Academy of Engineering
- NIHR Oxford Biomedical Research Centre
Zitieren
APA
Wu, W. (2024). Dynamic field mapping and distortion correction using single‐shot blip‐rewound EPI and joint multi‐echo reconstruction. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30038
Vancouver
Wu W. Dynamic field mapping and distortion correction using single‐shot blip‐rewound EPI and joint multi‐echo reconstruction. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30038
BibTeX
@article{Wu2024,
author = {Wu, Wenchuan},
title = {Dynamic field mapping and distortion correction using single‐shot blip‐rewound EPI and joint multi‐echo reconstruction},
journal = {Magnetic Resonance in Medicine},
year = {2024},
doi = {10.1002/mrm.30038}
}
EUVIMED