EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Dynamic field mapping and distortion correction using single‐shot blip‐rewound EPI and joint multi‐echo reconstruction

Wenchuan Wu iD

Magnetic Resonance in Medicine · 2024

DOI: 10.1002/mrm.30038 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Wenchuan Wu. Beteiligte Einrichtung: Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK. Hauptthemen laut MEDLINE: Algorithms, Phantoms, Imaging, Echo-Planar Imaging. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Wellcome Trust, Department of Health, Royal Academy of Engineering.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To develop a method for dynamic mapping and distortion correction.

Methods

A blip‐rewound EPI trajectory was developed to acquire multiple 2D EPI images in a single readout with an interleaved order, which allows a short TE difference. A joint multi‐echo reconstruction was utilized to exploit the shared information between EPI images. The reconstructed images from each readout are combined to produce a final magnitude image. A map is calculated from the phase of these images for distortion correction. The efficacy of the proposed method is assessed with phantom and in vivo experiments. The performance of the proposed method in the presence of subject motion is also investigated.

Results

Compared to conventional multi‐echo EPI, the proposed method allows dynamic mapping at matched resolution with a much shorter TR. Phantom and in vivo results show that the proposed method can provide a comparable magnitude image as conventional single‐shot EPI. The maps calculated from the proposed method are consistent with conventional multi‐echo EPI in the phantom experiment. For in vivo experiments, the proposed method provides a more accurate estimation of than conventional multi‐echo EPI, which is prone to phase wrapping problems due to the long TE difference. In‐vivo scan with subject motion shows the proposed dynamic field mapping method can improve the temporal stability of EPI time series compared to gradient echo (GRE) based static field mapping.

Conclusion

The proposed method allows accurate dynamic mapping for robust distortion correction without compromising spatial or temporal resolution.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AlgorithmsPhantoms, ImagingEcho-Planar ImagingHumansArtifactsReproducibility of ResultsImage EnhancementImage Interpretation, Computer-AssistedImage Processing, Computer-AssistedBrainSensitivity and Specificity

Stichwörter der Autor:innen

EPIdistortion correctiondynamic field mappingfMRImotion

Autor:innen und Institutionen

  • Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK.

ORCID-Profile: Wenchuan Wu

Förderung

  • Wellcome Trust
  • Department of Health
  • Royal Academy of Engineering
  • NIHR Oxford Biomedical Research Centre

Zitieren

APA

Wu, W. (2024). Dynamic field mapping and distortion correction using single‐shot blip‐rewound EPI and joint multi‐echo reconstruction. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30038

Vancouver

Wu W. Dynamic field mapping and distortion correction using single‐shot blip‐rewound EPI and joint multi‐echo reconstruction. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30038

BibTeX
@article{Wu2024,
  author = {Wu, Wenchuan},
  title = {Dynamic field mapping and distortion correction using single‐shot blip‐rewound EPI and joint multi‐echo reconstruction},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.30038}
}
Kostenlos starten →