A Modified Balanced Steady State Free Precession Sequence for Overhauser Magnetic Resonance Imaging
Magnetic Resonance in Medicine · 2026-10 · 96 (4) · 1655-1665
DOI: 10.1002/mrm.70453 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 07.06.2026. Verfasst von Kai Buckenmaier und 9 weiteren Autor:innen. Beteiligte Einrichtung: High-Field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Image Processing, Computer-Assisted. Die Arbeit nennt 69 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft, European Research Council.
Abstract (Originalsprache)
Purpose
Low‐ and ultralow‐field magnetic resonance imaging (ULF MRI) have inherently low signal‐to‐noise ratio (SNR) by design. Overhauser dynamic nuclear polarization (ODNP) stands out as an effective solution for continuous signal enhancement. To accelerate imaging and reduce radiofrequency (RF) power deposition—which is critical due to the high‐frequency RF fields required for ODNP—efficient pulse sequences are essential. For instance, a balanced steady‐state free precession (bSSFP) sequence offers high signal efficiency. However, conventional bSSFP sequences are susceptible to B 0 inhomogeneities and temporal field drifts, which can lead to banding artifacts.
Methods
In this work, we mitigated the limitations of banding artifacts by developing a modified bSSFP sequence (bSSFP180) that allows interleaved polarization and acquisition, thereby tailoring it for ODNP‐enhanced ULF MRI. The unmodified and modified sequences are compared in an imaging experiment.
Results
The proposed sequence effectively suppresses banding artifacts and demonstrates robust performance under inhomogeneous field conditions. Experimental MRI results demonstrated that bSSFP 180 achieves banding artifact‐free performance.
Conclusion
The banding artifact‐free bSSFP180 images represent a significant advancement toward the practical and reliable use of ODNP‐enhanced imaging in future biomedical applications. This is particularly relevant for MRI experiments that employ lightweight, cost‐efficient, permanent magnet systems in low‐field environments, which often face challenges related to field instability and inhomogeneity.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- High-Field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.
- Werner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, University Hospital Tübingen, Eberhard-Karls University, Tübingen, Germany.
- Cluster of Excellence iFIT (EXC 2180) "Image-Guided and Functionally Instructed Tumor Therapies, Eberhard-Karls University, Tübingen, Germany.
- German Cancer Consortium (DKTK) and German Cancer Research Center (DKFZ), Partner Site Tübingen, Tübingen, Germany.
ORCID-Profile: Kai Buckenmaier, Philipp Pohlmann, André Ferreira Martins, Klaus Scheffler
Förderung
- Deutsche Forschungsgemeinschaft
- European Research Council
Zitieren
APA
Buckenmaier, K., Bullinger, F., Solomakha, G. A., Schneider, M., Engelmann, J., Pohlmann, P., Povolni, P., Kuebler, L., Martins, A. F., & Scheffler, K. (2026). A Modified Balanced Steady State Free Precession Sequence for Overhauser Magnetic Resonance Imaging. Magnetic Resonance in Medicine, 96(4), 1655-1665. https://doi.org/10.1002/mrm.70453
Vancouver
Buckenmaier K, Bullinger F, Solomakha GA, Schneider M, Engelmann J, Pohlmann P, et al. A Modified Balanced Steady State Free Precession Sequence for Overhauser Magnetic Resonance Imaging. Magnetic Resonance in Medicine. 2026;96(4):1655-1665. doi:10.1002/mrm.70453
BibTeX
@article{Buckenmaier2026,
author = {Buckenmaier, Kai and Bullinger, Friedemann and Solomakha, Georgiy Alekseevich and Schneider, Marcel and Engelmann, Jörn and Pohlmann, Philipp and Povolni, Pavel and Kuebler, Laura and Martins, André Ferreira and Scheffler, Klaus},
title = {A Modified Balanced Steady State Free Precession Sequence for Overhauser Magnetic Resonance Imaging},
journal = {Magnetic Resonance in Medicine},
year = {2026},
volume = {96},
number = {4},
pages = {1655--1665},
doi = {10.1002/mrm.70453}
}
EUVIMED