Journal article in Magnetic Resonance in Medicine, published online on 2026-05-17. Written by Patrik Jan Gallinnis and 12 co-authors. Institution: Center for Advanced Preclinical Imaging (CAPI), First Faculty of Medicine, Charles University, Prague, Czech Republic. Major MEDLINE topics: Magnetic Resonance Imaging, Kidney, Image Processing, Computer-Assisted, Respiratory-Gated Imaging Techniques. 51 references. The full text is freely available (open access, CC BY 4.0). Funded by: Jürgen Manchot Stiftung, Univerzita Karlova v Praze, Deutsche Forschungsgemeinschaft.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

Endogenous renal chemical exchange saturation transfer (CEST) imaging enables contrast‐agent‐free assessment of renal metabolism but is highly sensitive to respiratory motion. Existing approaches, such as timed breathing, require high patient compliance or preclinical mechanical ventilation, limiting clinical translation. We evaluated a free‐breathing prospective respiratory triggering method that allows continuous saturation during active breathing while adaptively aligning image acquisition with the expiratory phase.

Methods

Prospective triggering was based on a modified real‐time respiratory signal, with a temporal shift continuously updated according to the current respiratory rate. Simulations assessed its performance across saturation durations of 1–6 s, respiratory rates representative of preclinical and clinical settings (f = 8–90 bpm), and varying respiratory frequency (CV = 0%–25%). Results were compared to conventional real‐time triggering. For in vivo validation, prospective triggering was implemented on a preclinical 7 T MRI system using a Raspberry Pi‐based hardware and software. Six mice underwent CEST imaging with saturation durations of 1, 3, and 5 s using both real‐time and prospective triggering, and the Mean Squared Error of Lorentzian fit was used to compare the two approaches.

Results

The real‐time trigger error shows a periodic dependence on respiratory frequency, which diminishes with increasing variability, whereas the prospective trigger reduces this periodicity. In vivo, prospective triggering significantly ( p < 0.05) reduced motion‐induced scattering in the Z‐spectrum for saturation times up to 3 s and enabled the detection of distinct metabolic contrasts across renal compartments.

Conclusion

Prospective triggering effectively reduces motion artifacts in preclinical renal CEST imaging.

Subjects

MeSH terms (MEDLINE)

Magnetic Resonance ImagingKidneyImage Processing, Computer-AssistedRespiratory-Gated Imaging TechniquesAnimalsMiceRespirationAlgorithmsReproducibility of ResultsPhantoms, ImagingComputer Simulation

Author keywords

abdominal CESTchemical exchange saturation transferkidneymagnetization transfer imagingrespiratory triggering

Authors and institutions

  • Center for Advanced Preclinical Imaging (CAPI), First Faculty of Medicine, Charles University, Prague, Czech Republic.
  • Department of Diagnostic and Interventional Radiology, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany.
  • F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA.
  • Division of Nephrology, Department of Medicine, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
  • MR Solutions Ltd, Surrey, UK.
  • CARID Cardiovascular Research Institute Düsseldorf, University, Hospital Düsseldorf, Heinrich-Heine-University, Düsseldorf, Germany.

ORCID profiles: Julia Stabinska, Karl Ludger Radke, Alexandra Ljimani, Hans-Jörg Wittsack, Vít Herynek

Funding

  • Jürgen Manchot Stiftung
  • Univerzita Karlova v Praze
  • Deutsche Forschungsgemeinschaft
  • Ministerstvo Školství, Mládeže a Tělovýchovy
  • European Regional Development Fund
  • NIH HHS
  • National Institutes of Health

Cite

APA

Gallinnis, P. J., Duša, M., Stabinska, J., Francová, P. V., Garipov, R., Tkachenko, M., Radke, K. L., Antoch, G., Ljimani, A., Wittsack, H. J., Šefc, L., Müller-Lutz, A., & Herynek, V. (2026). Toward Free‐Breathing Renal CEST MRI : Preclinical Evaluation of a Novel Prospective Respiratory Triggering Approach. Magnetic Resonance in Medicine, 96(3), 1333-1341. https://doi.org/10.1002/mrm.70435

Vancouver

Gallinnis PJ, Duša M, Stabinska J, Francová PV, Garipov R, Tkachenko M, et al. Toward Free‐Breathing Renal CEST MRI : Preclinical Evaluation of a Novel Prospective Respiratory Triggering Approach. Magnetic Resonance in Medicine. 2026;96(3):1333-1341. doi:10.1002/mrm.70435

BibTeX
@article{Gallinnis2026,
  author = {Gallinnis, Patrik Jan and Duša, Martin and Stabinska, Julia and Francová, Pavla Volešák and Garipov, Ruslan and Tkachenko, Margarita and Radke, Karl Ludger and Antoch, Gerald and Ljimani, Alexandra and Wittsack, Hans-Jörg and Šefc, Luděk and Müller-Lutz, Anja and Herynek, Vít},
  title = {Toward Free‐Breathing Renal CEST MRI : Preclinical Evaluation of a Novel Prospective Respiratory Triggering Approach},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  volume = {96},
  number = {3},
  pages = {1333--1341},
  doi = {10.1002/mrm.70435}
}
Start for free →