Group-Aware Registration for Lesion-Level Quantitative Motion Correction in Respiratory-Gated PET/CT Biomedical Imaging
Sensors · 17.07.2026 · 26 (14) · 4554
DOI: 10.3390/s26144554 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 17.07.2026. Verfasst von Hui Zhou und 5 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Information Engineering and Automation, Kunming University of Science and Technology, Kunming 650500, China. Hauptthemen laut MEDLINE: Positron Emission Tomography Computed Tomography, Image Processing, Computer-Assisted, Respiratory-Gated Imaging Techniques. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Special Basic Cooperative Research Programs of Yunnan Provincial Undergraduate Universities' Association, Social Development Special Project of the Yunnan Provincial Science and Technology Department.
Abstract (Originalsprache)
Respiratory-gated PET/CT generates phase-resolved biomedical imaging data, but respiratory motion can cause spatial mismatch and lesion-level quantitative instability, especially for small thoracoabdominal lesions. This study proposes SCAR-Net, a Similarity-Constrained Adaptive Respiratory Registration Network, for retrospective phase-to-reference correction of respiratory-gated 18F-FDG PET/CT. SCAR-Net treats motion correction as a quantitative stability problem in phase-resolved PET/CT rather than only a generic registration task. It combines sampled group-aware feature encoding with adaptive group-attentive modulation to represent structured respiratory deformation and enhance motion-sensitive correspondence. The method was evaluated using controlled respiratory simulations and a retrospective two-center clinical cohort of 100 patients, jointly assessing lesion-level SUV repeatability, spatial correspondence, image similarity, deformation plausibility, center-stratified performance with B-spline FFD as a conventional reference, cross-dataset testing without target-domain fine-tuning, ablation behavior, and computational efficiency. In the independent clinical test set, lesion-level evaluation included 20 patients, 43 independent PET-avid lesions, and 245 evaluable lesion-phase pairs. In small-lesion phase pairs, SCAR-Net reduced median phase-to-reference variability to 6.45% for |ΔSUVmax| and 4.73% for |ΔSUVmean|, and increased median lesion Dice from 0.55 to 0.72. In large-lesion phase pairs, SCAR-Net achieved a post-correction Dice of 0.89 and remained competitive for SUV repeatability. Descriptive center-stratified analysis showed a consistent lesion-level performance pattern across the two clinical acquisition settings. These findings suggest that SCAR-Net can improve phase consistency and quantitative stability in respiratory-gated PET/CT, with the clearest benefit observed in small-lesion assessment. Downstream clinical endpoints, such as diagnostic accuracy, tumor staging, PERCIST-based response assessment, and patient outcomes, were not evaluated and require future prospective validation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Faculty of Information Engineering and Automation, Kunming University of Science and Technology, Kunming 650500, China.
- College of Engineering, Yuxi Normal University, Yuxi 653100, China.
- Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education), Beijing Key Laboratory of Research, Investigation and Evaluation of Radiopharmaceuticals, NMPA Key Laboratory for Research and Evaluat…
ORCID-Profile: Yangsheng Hu
Förderung
- National Natural Science Foundation of China
- Special Basic Cooperative Research Programs of Yunnan Provincial Undergraduate Universities' Association
- Social Development Special Project of the Yunnan Provincial Science and Technology Department
- Yunnan Fuwai Cardiovascular Hospital Institutional-Level Strategic Research Project
- Peking University Cancer Hospital Scientific Research Fund
- Special Basic Cooperative Research Programs of Yunnan Provincial Undergraduate Universities’ Association
Zitieren
APA
Zhou, H., He, L., Hu, Y., Qin, Z., Wang, F., & He, J. (2026). Group-Aware Registration for Lesion-Level Quantitative Motion Correction in Respiratory-Gated PET/CT Biomedical Imaging. Sensors, 26(14), 4554. https://doi.org/10.3390/s26144554
Vancouver
Zhou H, He L, Hu Y, Qin Z, Wang F, He J. Group-Aware Registration for Lesion-Level Quantitative Motion Correction in Respiratory-Gated PET/CT Biomedical Imaging. Sensors. 2026;26(14):4554. doi:10.3390/s26144554
BibTeX
@article{Zhou2026,
author = {Zhou, Hui and He, Longxi and Hu, Yangsheng and Qin, Zhouyuan and Wang, Feng and He, Jianfeng},
title = {Group-Aware Registration for Lesion-Level Quantitative Motion Correction in Respiratory-Gated PET/CT Biomedical Imaging},
journal = {Sensors},
year = {2026},
volume = {26},
number = {14},
pages = {4554},
doi = {10.3390/s26144554}
}
EUVIMED