Toward Free‐Breathing Renal CEST MRI : Preclinical Evaluation of a Novel Prospective Respiratory Triggering Approach
Magnetic Resonance in Medicine · 2026-09 · 96 (3) · 1333-1341
DOI: 10.1002/mrm.70435 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 17.05.2026. Verfasst von Patrik Jan Gallinnis und 12 weiteren Autor:innen. Beteiligte Einrichtung: Center for Advanced Preclinical Imaging (CAPI), First Faculty of Medicine, Charles University, Prague, Czech Republic. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Kidney, Image Processing, Computer-Assisted, Respiratory-Gated Imaging Techniques. Die Arbeit nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Jürgen Manchot Stiftung, Univerzita Karlova v Praze, Deutsche Forschungsgemeinschaft.
Abstract (Originalsprache)
Purpose
Endogenous renal chemical exchange saturation transfer (CEST) imaging enables contrast‐agent‐free assessment of renal metabolism but is highly sensitive to respiratory motion. Existing approaches, such as timed breathing, require high patient compliance or preclinical mechanical ventilation, limiting clinical translation. We evaluated a free‐breathing prospective respiratory triggering method that allows continuous saturation during active breathing while adaptively aligning image acquisition with the expiratory phase.
Methods
Prospective triggering was based on a modified real‐time respiratory signal, with a temporal shift continuously updated according to the current respiratory rate. Simulations assessed its performance across saturation durations of 1–6 s, respiratory rates representative of preclinical and clinical settings (f = 8–90 bpm), and varying respiratory frequency (CV = 0%–25%). Results were compared to conventional real‐time triggering. For in vivo validation, prospective triggering was implemented on a preclinical 7 T MRI system using a Raspberry Pi‐based hardware and software. Six mice underwent CEST imaging with saturation durations of 1, 3, and 5 s using both real‐time and prospective triggering, and the Mean Squared Error of Lorentzian fit was used to compare the two approaches.
Results
The real‐time trigger error shows a periodic dependence on respiratory frequency, which diminishes with increasing variability, whereas the prospective trigger reduces this periodicity. In vivo, prospective triggering significantly ( p < 0.05) reduced motion‐induced scattering in the Z‐spectrum for saturation times up to 3 s and enabled the detection of distinct metabolic contrasts across renal compartments.
Conclusion
Prospective triggering effectively reduces motion artifacts in preclinical renal CEST imaging.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Center for Advanced Preclinical Imaging (CAPI), First Faculty of Medicine, Charles University, Prague, Czech Republic.
- Department of Diagnostic and Interventional Radiology, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany.
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA.
- Division of Nephrology, Department of Medicine, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
- MR Solutions Ltd, Surrey, UK.
- CARID Cardiovascular Research Institute Düsseldorf, University, Hospital Düsseldorf, Heinrich-Heine-University, Düsseldorf, Germany.
ORCID-Profile: Julia Stabinska, Karl Ludger Radke, Alexandra Ljimani, Hans-Jörg Wittsack, Vít Herynek
Förderung
- Jürgen Manchot Stiftung
- Univerzita Karlova v Praze
- Deutsche Forschungsgemeinschaft
- Ministerstvo Školství, Mládeže a Tělovýchovy
- European Regional Development Fund
- NIH HHS
- National Institutes of Health
Zitieren
APA
Gallinnis, P. J., Duša, M., Stabinska, J., Francová, P. V., Garipov, R., Tkachenko, M., Radke, K. L., Antoch, G., Ljimani, A., Wittsack, H. J., Šefc, L., Müller-Lutz, A., & Herynek, V. (2026). Toward Free‐Breathing Renal CEST MRI : Preclinical Evaluation of a Novel Prospective Respiratory Triggering Approach. Magnetic Resonance in Medicine, 96(3), 1333-1341. https://doi.org/10.1002/mrm.70435
Vancouver
Gallinnis PJ, Duša M, Stabinska J, Francová PV, Garipov R, Tkachenko M, et al. Toward Free‐Breathing Renal CEST MRI : Preclinical Evaluation of a Novel Prospective Respiratory Triggering Approach. Magnetic Resonance in Medicine. 2026;96(3):1333-1341. doi:10.1002/mrm.70435
BibTeX
@article{Gallinnis2026,
author = {Gallinnis, Patrik Jan and Duša, Martin and Stabinska, Julia and Francová, Pavla Volešák and Garipov, Ruslan and Tkachenko, Margarita and Radke, Karl Ludger and Antoch, Gerald and Ljimani, Alexandra and Wittsack, Hans-Jörg and Šefc, Luděk and Müller-Lutz, Anja and Herynek, Vít},
title = {Toward Free‐Breathing Renal CEST MRI : Preclinical Evaluation of a Novel Prospective Respiratory Triggering Approach},
journal = {Magnetic Resonance in Medicine},
year = {2026},
volume = {96},
number = {3},
pages = {1333--1341},
doi = {10.1002/mrm.70435}
}
EUVIMED