Optimizing Selective RF Pulses for Enhanced Signal Stability in Turbo Spin Echo Using a Differentiable Extended Phase Graph Model
Magnetic Resonance in Medicine · 2026-07 · 96 (1) · 214-226
DOI: 10.1002/mrm.70340 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 12.03.2026. Verfasst von Madison M Augelli und 3 weiteren Autor:innen. Beteiligte Einrichtung: Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Image Enhancement, Brain, Image Interpretation, Computer-Assisted. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science Foundation, Siemens Healthineers, NIH HHS.
Abstract (Originalsprache)
Purpose
To improve slice profile consistency across echo trains in turbo spin echo (TSE) imaging, thereby reducing image blurring and increasing the accuracy of multi echo spin echo mapping.
Methods
Excitation and refocusing RF pulses were optimized for TSE using a differentiable extended phase graph model that incorporates the spinor profiles of the RF pulses to calculate the magnetization slice profile across the echo train. The pulses were optimized using an L‐BFGS algorithm in PyTorch to minimize an error term on the target signal magnitude with singular value regularization to promote similarity. The performance of the optimized pulses was assessed by comparing to time bandwidth‐matched SLR RF pulses. Slice profile consistency was calculated in simulation and in a homogeneous phantom. Images were acquired in vivo to assess blurring artifacts, and measurements were acquired in a NIST phantom and in vivo to assess improvements in accuracy.
Results
The optimized pulses demonstrated superior performance over time bandwidth‐matched SLR pulses, with a 90% reduction in the standard deviation of the normalized integrated signal at each echo. Optimized pulses increased sharpness in vivo at the edges of CSF and veins perpendicular to the phase‐encoded direction, reduced mapping error in the NIST phantom by 91%, and produced more accurate in vivo maps.
Conclusion
The optimization method enables flexible design of RF pulses in echo train pulse sequences with consistent slice profiles, achieving a target signal progression while also maintaining a constant phase and FWHM between echoes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, USA.
- Department of Radiology, Case Western Reserve University, Cleveland, Ohio, USA.
ORCID-Profile: Madison M Augelli, Anuj Sharma, Mark A Griswold, William A Grissom
Förderung
- National Science Foundation
- Siemens Healthineers
- NIH HHS
- National Institutes of Health
Zitieren
APA
Augelli, M. M., Sharma, A., Griswold, M. A., & Grissom, W. A. (2026). Optimizing Selective RF Pulses for Enhanced Signal Stability in Turbo Spin Echo Using a Differentiable Extended Phase Graph Model. Magnetic Resonance in Medicine, 96(1), 214-226. https://doi.org/10.1002/mrm.70340
Vancouver
Augelli MM, Sharma A, Griswold MA, Grissom WA. Optimizing Selective RF Pulses for Enhanced Signal Stability in Turbo Spin Echo Using a Differentiable Extended Phase Graph Model. Magnetic Resonance in Medicine. 2026;96(1):214-226. doi:10.1002/mrm.70340
BibTeX
@article{Augelli2026,
author = {Augelli, Madison M and Sharma, Anuj and Griswold, Mark A and Grissom, William A},
title = {Optimizing Selective RF Pulses for Enhanced Signal Stability in Turbo Spin Echo Using a Differentiable Extended Phase Graph Model},
journal = {Magnetic Resonance in Medicine},
year = {2026},
volume = {96},
number = {1},
pages = {214--226},
doi = {10.1002/mrm.70340}
}
EUVIMED