EUVIMEDEUVIMED entdecken
Open Access

MOdulation ‐Guided ENcoding ( MOGEN ) Scheme for Vessel‐Encoded Arterial Spin Labeling

Hongwei Li iD, Thomas W Okell, Joseph G Woods iD, Yang Ji, Yuriko Suzuki iD, Tiansheng Qian, Yujun Liao, Jian Wang, Bin Xu, Ziqi Sun, Ying-Hua Chu, Yi-Cheng Hsu und 2 weitere

Magnetic Resonance in Medicine · 2026-07 · 96 (1) · 146-160

DOI: 10.1002/mrm.70335 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 07.03.2026. Verfasst von Hongwei Li und 13 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Science and Technology for Brain-Inspired Intelligence, Fudan University, Shanghai, China. Hauptthemen laut MEDLINE: Spin Labels, Magnetic Resonance Angiography, Moyamoya Disease, Image Processing, Computer-Assisted. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Natural Science Foundation of Shanghai, Wellcome Trust, National Key Research and Development Program of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Vessel‐encoded arterial spin labeling (VEASL) enables simultaneous, non‐contrast imaging of multiple vascular territories that is useful for differential diagnosis and treatment monitoring of cerebrovascular diseases. However, the existing encoding methods are signal‐to‐noise ratio (SNR) inefficient.

Methods

We developed a MOdulation‐Guided ENcoding (MOGEN) scheme that directly exploits the inversion spatial modulation profile to obtain SNR‐efficient encoding matrix. Simulations, phantom tests, and healthy volunteer scans were performed to demonstrate its feasibility in multiple application scenarios.

Results

Simulation studies demonstrated that MOGEN achieves significantly higher theoretical SNR efficiency than previous methods for both four‐ and six‐artery configurations. In healthy volunteers, MOGEN improved in vivo SNR by approximately 15% and provided more robust vessel decoding, particularly when the spatial modulation deviated from a cosine profile. In patients with Moyamoya disease, MOGEN enabled reliable visualization of collateral pathways even when scan time was reduced to ˜5 min for six arteries. Furthermore, by considering vessel size with multi‐voxel vessel representation, MOGEN enhanced single‐artery selectivity in vessel‐encoded angiography. We also demonstrated that a straightforward approach of off‐resonance correction for VEASL at ultra‐high field was feasible by using MOGEN.

Conclusion

MOGEN offered several benefits for VEASL, including high SNR efficiency, flexible spatial modulation and PCASL parameters selection, vessel size consideration, and straightforward off‐resonance correction, thereby substantially improving robustness and usability of VEASL across various applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Spin LabelsMagnetic Resonance AngiographyMoyamoya DiseaseImage Processing, Computer-AssistedArteriesHumansSignal-To-Noise RatioAlgorithmsPhantoms, ImagingComputer SimulationBrainAdultMaleFemaleCerebral ArteriesHealthy Volunteers

Stichwörter der Autor:innen

SNR efficiencyencoding schemevascular territoryvessel‐encoded arterial spin labeling (VEASL)vessel‐selective

Substanzen

Spin Labels

Autor:innen und Institutionen

  • Institute of Science and Technology for Brain-Inspired Intelligence, Fudan University, Shanghai, China.
  • Oxford Centre for Integrative Neuroimaging, FMRIB Division, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK.
  • Department of Electronic Engineering and Information Science, School of Information Science and Technology, University of Science and Technology of China, Hefei, China.
  • Department of Neurosurgery, Fudan University Huashan Hospital, Shanghai, China.
  • Clinical Medical Center of Neurosurgery, Shanghai Key Laboratory of Brain Function and Restoration and Neural Regeneration, Shanghai, China.
  • Department of Neurosurgery, The Second People's Hospital of Changzhou, The Third Affiliated Hospital of Nanjing Medical University, Changzhou Medical Center, Changzhou, China.

ORCID-Profile: Hongwei Li, Joseph G Woods, Yuriko Suzuki

Förderung

  • Natural Science Foundation of Shanghai
  • Wellcome Trust
  • National Key Research and Development Program of China
  • National Natural Science Foundation of China

Zitieren

APA

Li, H., Okell, T. W., Woods, J. G., Ji, Y., Suzuki, Y., Qian, T., Liao, Y., Wang, J., Xu, B., Sun, Z., Chu, Y. H., Hsu, Y. C., Wang, H., & Chen, Z. (2026). MOdulation ‐Guided ENcoding ( MOGEN ) Scheme for Vessel‐Encoded Arterial Spin Labeling. Magnetic Resonance in Medicine, 96(1), 146-160. https://doi.org/10.1002/mrm.70335

Vancouver

Li H, Okell TW, Woods JG, Ji Y, Suzuki Y, Qian T, et al. MOdulation ‐Guided ENcoding ( MOGEN ) Scheme for Vessel‐Encoded Arterial Spin Labeling. Magnetic Resonance in Medicine. 2026;96(1):146-160. doi:10.1002/mrm.70335

BibTeX
@article{Li2026,
  author = {Li, Hongwei and Okell, Thomas W and Woods, Joseph G and Ji, Yang and Suzuki, Yuriko and Qian, Tiansheng and Liao, Yujun and Wang, Jian and Xu, Bin and Sun, Ziqi and Chu, Ying-Hua and Hsu, Yi-Cheng and Wang, He and Chen, Zhensen},
  title = {MOdulation ‐Guided ENcoding ( MOGEN ) Scheme for Vessel‐Encoded Arterial Spin Labeling},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  volume = {96},
  number = {1},
  pages = {146--160},
  doi = {10.1002/mrm.70335}
}
Kostenlos starten →