Noncontrast MR Imaging of Blood–Brain Barrier Permeability: Halving Scan Time With Velocity‐Selective Preparation for Vessel Isolation
Magnetic Resonance in Medicine · 2026-08 · 96 (2) · 568-579
DOI: 10.1002/mrm.70349 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 24.03.2026. Verfasst von Yizhe Hu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory for Biomedical Engineering of the Ministry of Education, Department of Biomedical Engineering, College of Biomedical Engineering & Ins…. Hauptthemen laut MEDLINE: Blood-Brain Barrier, Magnetic Resonance Imaging, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 67 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities.
Abstract (Originalsprache)
Purpose
This study aims to develop and evaluate a noncontrast MRI method, Water‐Extraction‐with‐Fourier‐transform‐velocity‐selective‐Arterial‐Spin‐Tagging (WEFAST), for accelerated and robust measurement of blood–brain barrier (BBB) permeability to water.
Methods
The proposed WEFAST sequence incorporates Fourier‐Transform Velocity‐Selective (FTVS) preparation into the Water‐Extraction‐with‐Phase‐Contrast‐Arterial‐Spin‐Tagging (WEPCAST) MRI framework, enabling single‐shot acquisition without the need for double‐subtraction measurement. The imaging parameters of WEFAST were optimized for maximizing spatial and temporal SNR. Its reproducibility and evaluation against the established WEPCAST technique were performed.
Results
Optimal scan parameters were determined to be velocity cut‐off = 2 cm/s and FTVS flip angle = 90°, and the spatial SNR reached 10.42 ± 1.30 which is significantly higher than that of other imaging protocols (all p < 0.01). The scan time of WEFAST was significantly reduced (WEFAST vs. WEPCAST: 3 min 50 s vs. 6 min 54 s). The WEFAST sequence preserved robust reproducibility (intrasession CoV: extraction fraction ( E ) = 3.11% ± 0.67%, permeability surface area product (PS) = 11.08% ± 1.29%; intersession CoV: E = 3.17% ± 0.76%, PS = 12.33% ± 2.04%) and achieved good agreement with the WEPCAST in quantitative measurements ( R = 0.59, p < 0.001 for E ; R = 0.74, p < 0.001 for PS). Multidelay experiments further confirmed reliable quantification of venous water extraction signals in multiple venous structures such as the transverse sinus and straight sinus.
Conclusion
The proposed WEFAST sequence achieved significant acceleration in noncontrast BBB MR imaging by providing rapid and reliable quantification of BBB water permeability, with the potential for clinical applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Key Laboratory for Biomedical Engineering of the Ministry of Education, Department of Biomedical Engineering, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, China.
- MR Collaboration, Siemens Healthineers Ltd., Shanghai, China.
- Center for Biomedical Imaging Research, School of Biomedical Engineering, Tsinghua University, Beijing, China.
- Department of Radiology, University of Washington, Seattle, Washington, USA.
- The Russell H. Morgan Department of Radiology & Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
ORCID-Profile: Dan Wu, Qin Qin, Zixuan Lin
Förderung
- National Natural Science Foundation of China
- Fundamental Research Funds for the Central Universities
Zitieren
APA
Hu, Y., Hsu, Y. C., Wu, D., Zhao, X., Qin, Q., Lu, H., Zhao, L., & Lin, Z. (2026). Noncontrast MR Imaging of Blood–Brain Barrier Permeability: Halving Scan Time With Velocity‐Selective Preparation for Vessel Isolation. Magnetic Resonance in Medicine, 96(2), 568-579. https://doi.org/10.1002/mrm.70349
Vancouver
Hu Y, Hsu YC, Wu D, Zhao X, Qin Q, Lu H, et al. Noncontrast MR Imaging of Blood–Brain Barrier Permeability: Halving Scan Time With Velocity‐Selective Preparation for Vessel Isolation. Magnetic Resonance in Medicine. 2026;96(2):568-579. doi:10.1002/mrm.70349
BibTeX
@article{Hu2026,
author = {Hu, Yizhe and Hsu, Yi-Cheng and Wu, Dan and Zhao, Xihai and Qin, Qin and Lu, Hanzhang and Zhao, Li and Lin, Zixuan},
title = {Noncontrast MR Imaging of Blood–Brain Barrier Permeability: Halving Scan Time With Velocity‐Selective Preparation for Vessel Isolation},
journal = {Magnetic Resonance in Medicine},
year = {2026},
volume = {96},
number = {2},
pages = {568--579},
doi = {10.1002/mrm.70349}
}
EUVIMED