Human Brain High‐Resolution Diffusion MRI With Optimized, Slice‐By‐Slice, Zeroth and First Order B0 Shimming in Head‐Only High‐Gradient MRI Systems
Magnetic Resonance in Medicine · 2026-06 · 95 (6) · 3322-3332
DOI: 10.1002/mrm.70310 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 18.02.2026. Verfasst von Patricia Lan und 9 weiteren Autor:innen. Beteiligte Einrichtung: MR Clinical Solutions & Research Collaborations, GE HealthCare, Menlo Park, California, USA. Hauptthemen laut MEDLINE: Brain, Diffusion Magnetic Resonance Imaging, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NINDS NIH HHS, NIBIB NIH HHS, NIH HHS.
Abstract (Originalsprache)
Purpose
To propose a brain tissue‐selective, optimized slice‐by‐slice shimming for high‐resolution brain diffusion MRI.
Methods
We incorporated actual gradient fields of the , , and imaging gradient coils, which are already designed for fast switching and accessible to any MRI system, in the calculation of the shimming coefficients in dynamic slice‐by‐slice shimming to minimize field inhomogeneity (i.e., ) in deep‐learning segmented brain tissues. Diffusion MRI with oscillating gradient spin echo (OGSE) at 55 Hz and pulsed gradient spin echo (PGSE) (approximated at 0 Hz) were obtained in phantoms and healthy volunteers using a head‐only high‐gradient 3T MRI system. In each diffusion MRI acquisition, standard static volumetric shimming and the proposed shimming were applied separately, and mean/axial/radial diffusivities (MD/AD/RD) and fractional anisotropy (FA) were estimated.
Results
Compared to static shimming, dynamic shimming reduced the root‐mean‐square of voxel displacement of each slice by a maximum of 5–10 voxels in single‐shot EPI acquisition at 1–2 mm in‐plane resolution in the phantom, and a maximum of 3 voxels in human brains. Improved accuracy of MD/AD/RD/FA in the frontal lobe, brainstem, and cerebellum was observed by applying dynamic shimming and/or two‐shot EPI acquisition. MD (55 Hz)–MD (0 Hz) showed higher values in FSE hypo‐intensity region by applying dynamic shimming. Furthermore, in phantom, the root‐mean‐square of in areas with high gradient nonlinearity was reduced by 7 Hz when incorporating the actual gradient field in dynamic shimming.
Conclusion
Diffusion MRI with brain tissue‐selective, dynamic slice‐by‐slice effectively improves diffusivity characterization in high‐resolution images.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- MR Clinical Solutions & Research Collaborations, GE HealthCare, Menlo Park, California, USA.
- Science and Technology Office, GE HealthCare, Royal Oak, Michigan, USA.
- Technology & Innovation Center, GE HealthCare, Niskayuna, New York, USA.
- MR Clinical Solutions & Research Collaborations, GE HealthCare, Houston, Texas, USA.
- Department of Radiology, Brigham and Women's Hospital, Boston, Massachusetts, USA.
- Harvard Medical School, Boston, Massachusetts, USA.
ORCID-Profile: Patricia Lan, Sherry S Huang, Chitresh Bhushan, Xinzeng Wang, Seung-Kyun Lee, Desmond Teck Beng Yeo, Raymond Y Huang, Jerome J Maller, Jennifer A McNab, Ante Zhu
Förderung
- NINDS NIH HHS
- NIBIB NIH HHS
- NIH HHS
- National Institutes of Health
Zitieren
APA
Lan, P., Huang, S. S., Bhushan, C., Wang, X., Lee, S. K., Yeo, D. T. B., Huang, R. Y., Maller, J. J., McNab, J. A., & Zhu, A. (2026). Human Brain High‐Resolution Diffusion MRI With Optimized, Slice‐By‐Slice, Zeroth and First Order B0 Shimming in Head‐Only High‐Gradient MRI Systems. Magnetic Resonance in Medicine, 95(6), 3322-3332. https://doi.org/10.1002/mrm.70310
Vancouver
Lan P, Huang SS, Bhushan C, Wang X, Lee SK, Yeo DTB, et al. Human Brain High‐Resolution Diffusion MRI With Optimized, Slice‐By‐Slice, Zeroth and First Order B0 Shimming in Head‐Only High‐Gradient MRI Systems. Magnetic Resonance in Medicine. 2026;95(6):3322-3332. doi:10.1002/mrm.70310
BibTeX
@article{Lan2026,
author = {Lan, Patricia and Huang, Sherry S and Bhushan, Chitresh and Wang, Xinzeng and Lee, Seung-Kyun and Yeo, Desmond Teck Beng and Huang, Raymond Y and Maller, Jerome J and McNab, Jennifer A and Zhu, Ante},
title = {Human Brain High‐Resolution Diffusion MRI With Optimized, Slice‐By‐Slice, Zeroth and First Order B0 Shimming in Head‐Only High‐Gradient MRI Systems},
journal = {Magnetic Resonance in Medicine},
year = {2026},
volume = {95},
number = {6},
pages = {3322--3332},
doi = {10.1002/mrm.70310}
}
EUVIMED