EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

MoCo + ROVir : Synergy Between Respiratory Motion Compensation and Cardiac Receive Region Focusing for Cardiac MRI

Zheyuan Hu iD, Hsu-Lei Lee, Tianle Cao iD, Takegawa Yoshida, Lingceng Ma iD, J Paul Finn, Kim-Lien Nguyen iD, Anthony G Christodoulou iD

Magnetic Resonance in Medicine · 2026

DOI: 10.1002/mrm.70280 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Zheyuan Hu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiological Sciences, David Geffen School of Medicine at UCLA, Los Angeles, California, USA. Hauptthemen laut MEDLINE: Heart Defects, Congenital, Heart, Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Cine. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NHLBI NIH HHS, NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To improve cardiac motion representation and reduce artifacts for cardiac‐ and respiratory‐resolved imaging through a synergistic combination of retrospective cardiac phased array RF focusing and rigid respiratory motion compensation (MoCo).

Methods

We incorporated cardiac receive focusing using region‐optimized virtual coils (ROVir) and MoCo into cardiac‐ and respiratory‐resolved low‐rank tensor (LRT) reconstruction, hypothesizing that the combination of MoCo + ROVir would prioritize the LRT representation of cardiac motion over respiratory motion. We compared LRT, MoCo‐LRT, ROVir‐LRT, and the proposed MoCo + ROVir‐LRT reconstructions of retrospective data from N = 24 pediatric patients with congenital heart disease (CHD) scanned at 3.0 T using ROCK‐MUSIC. Technical evaluation metrics included the proportion of cardiac‐to‐respiratory motion energy in self‐gating lines, cardiac motion priority in the temporal basis, flickering energy, and edge sharpness in end‐expiratory cardiac cine. Reconstructed cardiac cines were scored by two expert image readers.

Results

MoCo + ROVir significantly increased the proportion of cardiac‐to‐respiratory motion energy in self‐gating lines ( p < 0.001) and prioritized cardiac motion in the temporal basis ( p < 0.001). MoCo + ROVir reduced flickering energy in cardiac cine images ( p < 0.001), sharpened the liver–lung interface ( p < 0.001), and improved flickering‐specific scores ( p = 0.001). Myocardium–blood pool interface sharpness ( p = 0.831), cardiac‐specific image scores ( p = 0.188), and vascular‐specific scores ( p = 0.901) were not significantly different. Together, these two techniques allowed 3.7–5.2× faster reconstruction times versus LRT‐only.

Conclusion

The synergy of MoCo + ROVir successfully prioritized cardiac motion, suppressed respiratory motion, and reduced flickering artifacts, with an added benefit of accelerating reconstruction times. The improved respiratory motion handling may provide an avenue for free‐breathing cardiac scans in pediatric patients with CHD.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart Defects, CongenitalHeartImage Processing, Computer-AssistedMagnetic Resonance Imaging, CineMagnetic Resonance ImagingHumansArtifactsMaleFemaleRetrospective StudiesChildRespirationMotionChild, PreschoolAlgorithmsInfantImage Interpretation, Computer-AssistedMovement

Stichwörter der Autor:innen

cardiac MRIcongenital heart diseaselow‐rank tensormultichannel MRIpediatric MRIsignal suppression

Autor:innen und Institutionen

  • Department of Radiological Sciences, David Geffen School of Medicine at UCLA, Los Angeles, California, USA.
  • Department of Bioengineering, University of California, Los Angeles, Los Angeles, California, USA.
  • Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA.
  • Physics in Biology and Medicine Interdepartmental Program, UCLA Graduate Programs in Bioscience, University of California, Los Angeles, Los Angeles, California, USA.
  • Division of Cardiology, David Geffen School of Medicine at UCLA and VA Greater Los Angeles Healthcare System, Los Angeles, California, USA.

ORCID-Profile: Zheyuan Hu, Tianle Cao, Lingceng Ma, Kim-Lien Nguyen, Anthony G Christodoulou

Förderung

  • NHLBI NIH HHS
  • NIH HHS
  • National Institutes of Health

Zitieren

APA

Hu, Z., Lee, H. L., Cao, T., Yoshida, T., Ma, L., Finn, J. P., Nguyen, K. L., & Christodoulou, A. G. (2026). MoCo + ROVir : Synergy Between Respiratory Motion Compensation and Cardiac Receive Region Focusing for Cardiac MRI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70280

Vancouver

Hu Z, Lee HL, Cao T, Yoshida T, Ma L, Finn JP, et al. MoCo + ROVir : Synergy Between Respiratory Motion Compensation and Cardiac Receive Region Focusing for Cardiac MRI. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70280

BibTeX
@article{Hu2026,
  author = {Hu, Zheyuan and Lee, Hsu-Lei and Cao, Tianle and Yoshida, Takegawa and Ma, Lingceng and Finn, J Paul and Nguyen, Kim-Lien and Christodoulou, Anthony G},
  title = {MoCo + ROVir : Synergy Between Respiratory Motion Compensation and Cardiac Receive Region Focusing for Cardiac MRI},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70280}
}
Kostenlos starten →