Enhancing cardiac MRI reliability at 3 T using motion‐adaptive B 0 shimming
Magnetic Resonance in Medicine · 2026
DOI: 10.1002/mrm.70026 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Yuheng Huang und 18 weiteren Autor:innen. Beteiligte Einrichtung: Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Heart, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NINDS NIH HHS, NHLBI NIH HHS, National Institute of Health Sciences.
Abstract (Originalsprache)
Purpose
Magnetic susceptibility differences at the heart–lung interface introduce B 0 ‐field inhomogeneities that challenge cardiac MRI at high field strengths (≥ 3 T). Although hardware‐based shimming has advanced, conventional approaches often neglect dynamic variations in thoracic anatomy caused by cardiac and respiratory motion, leading to residual off‐resonance artifacts. This study aims to characterize motion‐induced B 0 ‐field fluctuations in the heart and evaluate a deep learning–enabled motion‐adaptive B 0 shimming pipeline to mitigate them.
Methods
A motion‐resolved B 0 mapping sequence was implemented at 3 T to quantify cardiac and respiratory‐induced B 0 variations. A motion‐adaptive shimming framework was then developed and validated through numerical simulations and human imaging studies. B 0 ‐field homogeneity and T 2 * mapping accuracy were assessed in multiple breath‐hold positions using standard and motion‐adaptive shimming.
Results
Respiratory motion significantly altered myocardial B 0 fields ( p < 0.01), whereas cardiac motion had minimal impact ( p = 0.49). Compared with conventional scanner shimming, motion‐adaptive B 0 shimming yielded significantly improved field uniformity across both inspiratory (post‐shim SD ratio : 0.68 ± 0.10 vs. 0.89 ± 0.11; p < 0.05) and expiratory (0.65 ± 0.16 vs. 0.84 ± 0.20; p < 0.05) breath‐hold states. Corresponding improvements in myocardial T 2 * map homogeneity were observed, with reduced coefficient of variation (0.44 ± 0.19 vs. 0.39 ± 0.22; 0.59 ± 0.30 vs. 0.46 ± 0.21; both p < 0.01).
Conclusion
The proposed motion‐adaptive B 0 shimming approach effectively compensates for respiration‐induced B 0 fluctuations, enhancing field homogeneity and reducing off‐resonance artifacts. This strategy improves the robustness and reproducibility of T 2 * mapping, enabling more reliable high‐field cardiac MRI.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA.
- Department of Radiology & Imaging Sciences, Indiana University School of Medicine, Indianapolis, Indiana, USA.
- Bioengineering, University of California, Los Angeles, Los Angeles, California, USA.
- MRI Research Institute, Department of Radiology, Weill Cornell Medicine, New York, New York, USA.
- MR R&D Collaborations, Siemens Medical Solutions Inc., Los Angeles, California, USA.
- Department of Imaging, Cedars-Sinai Medical Center, Los Angeles, California, USA.
ORCID-Profile: Yuheng Huang, Archana Vadiraj Malagi, Xingmin Guan, Hui Han
Förderung
- NINDS NIH HHS
- NHLBI NIH HHS
- National Institute of Health Sciences
Zitieren
APA
Huang, Y., Malagi, A. V., Li, X., Guan, X., Yang, C. C., Huang, L. T., Long, Z., Zepeda, J., Zhang, X., Yoosefian, G., Bi, X., Gao, C., Shang, Y., Binesh, N., Lee, H. L., Li, D., Dharmakumar, R., Han, H., & Yang, H. R. (2026). Enhancing cardiac MRI reliability at 3 T using motion‐adaptive B 0 shimming. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70026
Vancouver
Huang Y, Malagi AV, Li X, Guan X, Yang CC, Huang LT, et al. Enhancing cardiac MRI reliability at 3 T using motion‐adaptive B 0 shimming. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70026
BibTeX
@article{Huang2026,
author = {Huang, Yuheng and Malagi, Archana Vadiraj and Li, Xinqi and Guan, Xingmin and Yang, Chia-Chi and Huang, Li-Ting and Long, Ziyang and Zepeda, Jeremy and Zhang, Xinheng and Yoosefian, Ghazal and Bi, Xioaming and Gao, Chang and Shang, Yun and Binesh, Nader and Lee, Hsu-Lei and Li, Debiao and Dharmakumar, Rohan and Han, Hui and Yang, Hsin-Jung R},
title = {Enhancing cardiac MRI reliability at 3 T using motion‐adaptive B 0 shimming},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70026}
}
EUVIMED