Next Generation 7 Tesla Arterial Spin Labeling With Rotated Spiral Acquisition Enables Mesoscale Resolution in 3D Brain Perfusion and Functional MRI

Chenyang Zhao iD, Fanhua Guo, Zidong Yang, Xingfeng Shao iD, Samantha J Ma, Alexander J S Beckett, An T Vu, David A Feinberg, Danny J J Wang iD

Magnetic Resonance in Medicine · 2026-05 · 95 (5) · 2702-2717

DOI: 10.1002/mrm.70265 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, published online on 2026-01-29. Written by Chenyang Zhao and 8 co-authors. Institution: Laboratory of FMRI Technology (LOFT), Mark & Mary Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern Cal…. Major MEDLINE topics: Brain Mapping, Imaging, Three-Dimensional. Cited 6 times so far (Crossref); 75 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: NIH HHS, NINDS NIH HHS, National Institutes of Health.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

To achieve high resolution (≤ 1 mm isotropic) whole‐brain perfusion imaging at 7 T with next generation ASL pulse sequence, reconstruction algorithm, and MRI hardware.

Methods

We capitalized on three major innovations: (1) FLASH‐based pseudo‐Continuous ASL (pCASL) sequence with rotated golden‐angle stack‐of‐spirals (rGA‐SoS) sampling; (2) dynamic compressed sensing (CS) reconstruction with high spatiotemporal resolution and motion‐resolved self‐navigation; and (3) high density array coil and high‐performance Impulse gradient of the NexGen 7 T scanner. Whole‐brain laminar perfusion imaging was validated by correlation with histological data of microvascular and cell body density, as well as through finger‐tapping (FT) and working memory (WM) fMRI tasks.

Results

The proposed rGA‐SoS sequence achieved a 3.3‐fold SNR and 2‐fold higher intraclass correlation coefficient (ICC) compared to matched Cartesian sampling at 7 T, enabling up to 0.8 mm isotropic spatial resolution and/or a temporal resolution of 14 s at 1 mm isotropic. Resting‐state perfusion showed strong correlations with microvascular and cell body density. Laminar perfusion fMRI revealed a two‐peak activation in the primary motor cortex induced by FT, and distinct laminar profiles for task‐positive and task‐negative networks during WM task.

Conclusion

This method offers a noninvasive imaging tool to bridge the gap between mesoscopic MRI with microscopic cellular imaging, as well as to investigate neural excitation and inhibition underlying positive and negative fMRI activations.

Subjects

MeSH terms (MEDLINE)

Brain MappingImaging, Three-DimensionalHumansMaleFemaleAdultImage Processing, Computer-AssistedSpin LabelsSignal-To-Noise RatioBrain

Author keywords

BigBrain atlasNexGen 7 Tarterial spin labeling (ASL)layer fMRImicroscopic imagingultrahigh‐field MRIworking memory

Substances

Spin Labels

Authors and institutions

  • Laboratory of FMRI Technology (LOFT), Mark & Mary Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern California, Los Angeles, California, USA.
  • Siemens Medical Solutions USA, Los Angeles, California, USA.
  • Helen Wills Neuroscience Institute, University of California, Berkeley, California, USA.
  • Radiology and Biomedical Imaging, University of California, San Francisco, California, USA.
  • Northern California Institute for Research and Education, San Francisco, California, USA.

ORCID profiles: Chenyang Zhao, Xingfeng Shao, Danny J J Wang

Funding

  • NIH HHS
  • NINDS NIH HHS
  • National Institutes of Health

Cite

APA

Zhao, C., Guo, F., Yang, Z., Shao, X., Ma, S. J., Beckett, A. J. S., Vu, A. T., Feinberg, D. A., & Wang, D. J. J. (2026). Next Generation 7 Tesla Arterial Spin Labeling With Rotated Spiral Acquisition Enables Mesoscale Resolution in 3D Brain Perfusion and Functional MRI. Magnetic Resonance in Medicine, 95(5), 2702-2717. https://doi.org/10.1002/mrm.70265

Vancouver

Zhao C, Guo F, Yang Z, Shao X, Ma SJ, Beckett AJS, et al. Next Generation 7 Tesla Arterial Spin Labeling With Rotated Spiral Acquisition Enables Mesoscale Resolution in 3D Brain Perfusion and Functional MRI. Magnetic Resonance in Medicine. 2026;95(5):2702-2717. doi:10.1002/mrm.70265

BibTeX
@article{Zhao2026,
  author = {Zhao, Chenyang and Guo, Fanhua and Yang, Zidong and Shao, Xingfeng and Ma, Samantha J and Beckett, Alexander J S and Vu, An T and Feinberg, David A and Wang, Danny J J},
  title = {Next Generation 7 Tesla Arterial Spin Labeling With Rotated Spiral Acquisition Enables Mesoscale Resolution in 3D Brain Perfusion and Functional MRI},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  volume = {95},
  number = {5},
  pages = {2702--2717},
  doi = {10.1002/mrm.70265}
}