Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2026. Verfasst von Jiaying Zhang und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Biomedical Engineering, ShanghaiTech University, Shanghai, China. Hauptthemen laut MEDLINE: Deep Learning, Kidney, Magnetic Resonance Imaging, Image Processing, Computer-Assisted. Die Arbeit nennt 23 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The multi-TI flow-sensitive alternating inversion recovery sequence is a common ASL technique for probing renal perfusion. However, traditional method for quantifying perfusion, bolus arrival time (BAT) and bolus length (BL) from the images faces challenges due to low signal-to-noise ratio, large vessel contamination, and the absence of magnetization direction information in magnitude images. We proposed a BiLSTM-based deep learning (DL) approach for quantifying perfusion, BAT, and BL, and excluding large vessels. The network was trained on simulated pixel-wise multi-TI signals and tested using simulated and in vivo data. For comparison, the traditional quantification based on Buxton's model fitting was carried out, and manual cortex, medulla, and large vessel masks were drawn on fully relaxed magnitude images. For in vivo data, the quantification results from averages over all repetitions served as reference. In simulation, the DL approach had smaller quantification errors for perfusion and BAT but larger errors for BL than the traditional method. All in vivo parameters derived from the traditional method deviated more from references as number of averages decreased than those derived from DL. The DL masks excluded more high-perfusion pixels than the manual masks. Significant differences between the traditional and DL methods' quantification of in vivo perfusion, BAT, and BL cannot be explained by their differences observed in simulation, suggesting differences between simulated and in vivo data characteristics. The proposed network may serve as a useful tool for quantification in ASL, which is more accurate and more robust against noise than the traditional method.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep LearningKidneyMagnetic Resonance ImagingImage Processing, Computer-AssistedHumansSpin LabelsSignal-To-Noise RatioAlgorithmsMaleAdultComputer SimulationFemalePerfusionRenal Artery

Stichwörter der Autor:innen

Arterial spin labelingDeep learningMagnetic resonance imagingRenal perfusion

Substanzen

Spin Labels

Autor:innen und Institutionen

  • School of Biomedical Engineering, ShanghaiTech University, Shanghai, China.
  • Central Research Institute, Shanghai United Imaging Healthcare Co Ltd, Shanghai, China.
  • School of Biomedical Engineering, ShanghaiTech University, Shanghai, China; State Key Laboratory of Advanced Medical Materials and Devices, ShanghaiTech University, Shanghai 201210, China; Shanghai Clinical Research and…

Zitieren

APA

Zhang, J., Kong, X., Lin, X., Li, Y., Zhang, J. L., & Zong, X. (2026). Deep learning-based perfusion quantification and large vessel exclusion for renal multi-TI arterial spin labelling MRI. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2025.110573

Vancouver

Zhang J, Kong X, Lin X, Li Y, Zhang JL, Zong X. Deep learning-based perfusion quantification and large vessel exclusion for renal multi-TI arterial spin labelling MRI. Magnetic Resonance Imaging. 2026. doi:10.1016/j.mri.2025.110573

BibTeX
@article{Zhang2026,
  author = {Zhang, Jiaying and Kong, Xiangwei and Lin, Xi and Li, Yanbin and Zhang, Jeff L and Zong, Xiaopeng},
  title = {Deep learning-based perfusion quantification and large vessel exclusion for renal multi-TI arterial spin labelling MRI},
  journal = {Magnetic Resonance Imaging},
  year = {2026},
  doi = {10.1016/j.mri.2025.110573}
}
Kostenlos starten →