Advancing 7T perfusion imaging by pulsed arterial spin labeling: Using a parallel transmit coil for enhanced labeling robustness and temporal SNR
PLOS ONE · 2024
DOI: 10.1371/journal.pone.0309204 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, 2024. Verfasst von Ícaro Agenor Ferreira Oliveira und 4 weiteren Autor:innen. Beteiligte Einrichtung: Spinoza Centre for Neuroimaging, Netherlands Academy for Arts and Sciences, Amsterdam, Netherlands. Hauptthemen laut MEDLINE: Spin Labels, Signal-To-Noise Ratio, Perfusion Imaging. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NWO.
Abstract (Originalsprache)
Non-invasive perfusion imaging by Arterial spin labeling (ASL) can be advantageous at Ultra-high field (UHF) MRI, since the image SNR and the T1 relaxation time both increase with the static field. However, ASL implementation, especially at 7T, is not trivial. Especially for ASL, UHF MRI comes with many challenges, mainly due to B 1 + inhomogeneities. This study aimed to investigate the effects of different transmit coil configurations on perfusion-weighted imaging at 7T using a flow-sensitive alternating inversion recovery (FAIR) technique with time-resolved frequency offset corrected inversion (TR-FOCI) pulses for labeling and background suppression. We conducted a performance comparison between a parallel transmit (pTx) system equipped with 32 receive (Rx) and 8 transmit (Tx) channels and a standard setup with 32Rx and 2Tx channels. Our findings demonstrate that the pTx system, characterized by a more homogeneous B 1 transmit field, resulted in a significantly higher contrast-to-noise ratio, temporal signal-to-noise ratio, and lower coefficient of variance (CoV) than the standard 2Tx setup. Additionally, both setups demonstrated comparable capabilities for functional mapping of the hand region in the motor cortex, achieving reliable results within a short acquisition time of approximately 5 minutes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Spinoza Centre for Neuroimaging, Netherlands Academy for Arts and Sciences, Amsterdam, Netherlands.
- Computational Cognitive Neuroscience and Neuroimaging, Netherlands Institute for Neuroscience, Amsterdam, Netherlands.
- Krembil Brain Institute, University Health Network, Toronto, Ontario, Canada.
- C.J. Gorter MRI Center, Department of Radiology, Leiden University Medical Center, Leiden, Netherlands.
ORCID-Profile: Ícaro Agenor Ferreira Oliveira, Wietske van der Zwaag, Lydiane Hirschler
Förderung
- NWO
Zitieren
APA
Oliveira, Í. A. F., Schnabel, R., van Osch, M. J. P., Zwaag, W. V., & Hirschler, L. (2024). Advancing 7T perfusion imaging by pulsed arterial spin labeling: Using a parallel transmit coil for enhanced labeling robustness and temporal SNR. PLOS ONE. https://doi.org/10.1371/journal.pone.0309204
Vancouver
Oliveira ÍAF, Schnabel R, van Osch MJP, Zwaag WV, Hirschler L. Advancing 7T perfusion imaging by pulsed arterial spin labeling: Using a parallel transmit coil for enhanced labeling robustness and temporal SNR. PLOS ONE. 2024. doi:10.1371/journal.pone.0309204
BibTeX
@article{Oliveira2024,
author = {Oliveira, Ícaro Agenor Ferreira and Schnabel, Robin and van Osch, Matthias J P and Zwaag, Wietske van der and Hirschler, Lydiane},
title = {Advancing 7T perfusion imaging by pulsed arterial spin labeling: Using a parallel transmit coil for enhanced labeling robustness and temporal SNR},
journal = {PLOS ONE},
year = {2024},
doi = {10.1371/journal.pone.0309204}
}