Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Felix Glang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Brain. Die Arbeit nennt 67 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Max-Planck-Gesellschaft, Deutsche Forschungsgemeinschaft, European Research Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Investigating time‐division multiplexing for parallel transmission in ultra high‐field imaging, striving for homogeneous whole brain excitation with a limited number of RF channels.

Methods

A fast RF switch was built to alternately route 8 transmit channels to each row of a double‐row 16‐element transmit coil array at a 9.4 T human MRI system. Methods for SAR monitoring and pulse design for this temporal degree of freedom were developed and investigated in electromagnetic simulations and in vivo measurements, employing parallel transmission kT points pulses aiming for homogeneous whole‐brain excitation. The achievable trade‐off between local SAR and excitation homogeneity was compared for multiplexed and simultaneous transmission.

Results

Using time‐division multiplexing, similar excitation fidelity as with 16 transmit channels can be achieved with only 8 channels. For instance, multiplexing reduces the flip angle inhomogeneity by 2.22‐fold compared to exciting only a single row of the array, and by 1.85‐fold compared to statically splitting and routing 8 channels to 16 transmit coil elements. As a trade‐off, compared to simultaneous excitation, multiplexing requires either increased pulse duration or amplitudes, the latter causing increased SAR. However, with appropriate SAR‐aware pulse design, the multiplexing‐induced local SAR increase can be controlled. This allows for viable pulse design solutions for the considered low‐flip‐angle imaging scenarios.

Conclusion

Time‐division multiplexing allows driving a larger number of transmit elements with a smaller number of RF channels, resulting in improved parallel transmission performance. This opens up new possibilities for using advanced multi‐row transmit coil arrays in sites with only 8 RF channels available.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingBrainHumansPhantoms, ImagingRadio WavesEquipment DesignComputer SimulationAlgorithmsImage Processing, Computer-Assisted

Stichwörter der Autor:innen

RF switchSARflip angle homogeneityhigh‐field MRImultiplexing

Autor:innen und Institutionen

  • Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.
  • Institute of Biomedical Imaging, Graz University of Technology, Graz, Austria.
  • Department of Biomedical Magnetic Resonance, Eberhard Karls University Tübingen, Tübingen, Germany.
  • MRI Core Facility of the Medical Faculty, University of Tübingen, Tübingen, Germany.

ORCID-Profile: Felix Glang, Georgiy A Solomakha, Dario Bosch, Klaus Scheffler, Nikolai I Avdievich

Förderung

  • Max-Planck-Gesellschaft
  • Deutsche Forschungsgemeinschaft
  • European Research Council

Zitieren

APA

Glang, F., Solomakha, G. A., Bosch, D., Scheffler, K., & Avdievich, N. I. (2025). Time‐Division Multiplexing for Parallel Transmission at Ultra‐High Field With Limited RF Channels. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70230

Vancouver

Glang F, Solomakha GA, Bosch D, Scheffler K, Avdievich NI. Time‐Division Multiplexing for Parallel Transmission at Ultra‐High Field With Limited RF Channels. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.70230

BibTeX
@article{Glang2025,
  author = {Glang, Felix and Solomakha, Georgiy A and Bosch, Dario and Scheffler, Klaus and Avdievich, Nikolai I},
  title = {Time‐Division Multiplexing for Parallel Transmission at Ultra‐High Field With Limited RF Channels},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.70230}
}
Kostenlos starten →