EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Investigation of Endogenous Renal CEST Contrast and the Influence of Respiratory Motion on a Clinical 3 Tesla MRI : An In Vivo and In Vitro Study

Patrik Jan Gallinnis, Benedikt Kamp iD, Karl Ludger Radke iD, Rika Möller, Anna-Katharina Juric, Julia Stabinska iD, Vít Herynek, Gerald Antoch, Hans-Jörg Wittsack iD, Alexandra Ljimani iD, Anja Müller-Lutz

Magnetic Resonance in Medicine · 2026

DOI: 10.1002/mrm.70210 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Patrik Jan Gallinnis und 10 weiteren Autor:innen. Beteiligte Einrichtung: Medical Faculty, Department of Diagnostic and Interventional Radiology, University Dusseldorf, Dusseldorf, Germany. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Kidney, Respiration. Die Arbeit nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Jürgen Manchot Stiftung.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The aim is to evaluate the effectiveness of timed breathing in reducing respiratory motion artifacts in renal chemical exchange saturation transfer (CEST) MRI and to assess potential differences in CEST effects between renal compartments.

Methods

An electro‐pneumatic phantom with a kidney CEST model simulated variable respiratory motion and sequence‐synchronized breathing. Motion‐induced deviations from a static reference were quantified using the mean absolute error (MAE). Ten healthy volunteers (six females, four males; 25.2 ± 1.9 years) and one patient (47 years) with ccRCC (3.0 × 2.2 × 2.2) cm 3 were examined on a 3 T MRI system using a multi‐echo gradient echo sequence with 15 Gaussian‐shaped saturation pulses (B 1 = 1.5 μT, t p = t ipd = 100 ms). CEST effects in cortex, medulla, and pelvis at 1.0, 2.0, and 3.5 ppm were quantified by MTR asym analysis under timed and free‐breathing conditions.

Results

Timed breathing reduced motion artifacts in both phantom and in vivo data. MTR asym analysis exhibits visibly distinguishable and significantly different ( p < 0.05) CEST effects in renal compartments, with increased MTR asym values of (0.78% ± 0.41%) at 1.0 ppm in the cortex, (1.43% ± 0.70%) at 2.0 ppm in the medulla, and (−2.02% ± 0.84%) at 3.5 ppm in the pelvis. Significant differences ( p < 0.05) in MTR asym values were observed between the patient and the healthy cohort.

Conclusion

Timed breathing improves renal CEST MRI by reducing motion artifacts and enabling detection of compartment‐specific CEST effects, highlighting its potential for biochemical characterization of renal tissue in clinical applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingKidneyRespirationHumansMaleFemaleAdultPhantoms, ImagingArtifactsMotionMiddle AgedImage Processing, Computer-AssistedHealthy Volunteers

Stichwörter der Autor:innen

abdominal CESTamide proton transferchemical exchange saturation transferdynamic phantomkidneymagnetization transfer imaging

Autor:innen und Institutionen

  • Medical Faculty, Department of Diagnostic and Interventional Radiology, University Dusseldorf, Dusseldorf, Germany.
  • F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA.
  • Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
  • Center for Advanced Preclinical Imaging (CAPI), First Faculty of Medicine, Charles University, Prague, Czech Republic.
  • CARID, Cardiovascular Research Institute Düsseldorf, University Hospital Düsseldorf, Heinrich-Heine-University, Dusseldorf, Germany.

ORCID-Profile: Benedikt Kamp, Karl Ludger Radke, Julia Stabinska, Hans-Jörg Wittsack, Alexandra Ljimani

Förderung

  • Jürgen Manchot Stiftung

Zitieren

APA

Gallinnis, P. J., Kamp, B., Radke, K. L., Möller, R., Juric, A. K., Stabinska, J., Herynek, V., Antoch, G., Wittsack, H. J., Ljimani, A., & Müller-Lutz, A. (2026). Investigation of Endogenous Renal CEST Contrast and the Influence of Respiratory Motion on a Clinical 3 Tesla MRI : An In Vivo and In Vitro Study. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70210

Vancouver

Gallinnis PJ, Kamp B, Radke KL, Möller R, Juric AK, Stabinska J, et al. Investigation of Endogenous Renal CEST Contrast and the Influence of Respiratory Motion on a Clinical 3 Tesla MRI : An In Vivo and In Vitro Study. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70210

BibTeX
@article{Gallinnis2026,
  author = {Gallinnis, Patrik Jan and Kamp, Benedikt and Radke, Karl Ludger and Möller, Rika and Juric, Anna-Katharina and Stabinska, Julia and Herynek, Vít and Antoch, Gerald and Wittsack, Hans-Jörg and Ljimani, Alexandra and Müller-Lutz, Anja},
  title = {Investigation of Endogenous Renal CEST Contrast and the Influence of Respiratory Motion on a Clinical 3 Tesla MRI : An In Vivo and In Vitro Study},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70210}
}
Kostenlos starten →