Advancing whole‐brain BOLD functional MRI in humans at 10.5 T with motion‐robust 3D echo‐planar imaging , parallel transmission, and high‐density radiofrequency receive coils
Magnetic Resonance in Medicine · 2026
DOI: 10.1002/mrm.70110 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Shuxian Qu und 15 weiteren Autor:innen. Beteiligte Einrichtung: Center for Magnetic Resonance Research, Radiology, Medical School, University of Minnesota Twin Cities, Minneapolis, Minnesota, USA. Hauptthemen laut MEDLINE: Brain, Echo-Planar Imaging, Imaging, Three-Dimensional, Magnetic Resonance Imaging. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 111 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS, NCRR NIH HHS, NINDS, NIH.
Abstract (Originalsprache)
Purpose
To demonstrate the feasibility and performance of whole‐brain blood oxygen level–dependent functional MRI (fMRI) in humans at 10.5 T by combining motion‐robust three‐dimensional gradient‐echo echo‐planar imaging, parallel transmission, and high‐density radiofrequency (RF) receive coils.
Methods
Resting‐state fMRI time series were collected in healthy adults at 1.58 mm and approximately 2‐s spatiotemporal resolution using a custom‐built 16‐channel transmit/80‐channel receive RF array. Individualized parallel‐transmission, spatial‐spectral RF pulses were designed to achieve uniform water‐selective excitation across the entire brain without the need for additional fat saturation. Images were reconstructed with navigator‐guided joint motion and field correction. Reconstructed images were preprocessed using fMRIPrep and postprocessed using XCP‐D pipelines. Relevant resting‐state fMRI metrics were evaluated including temporal SNR (tSNR), amplitude of low‐frequency fluctuation, and regional homogeneity. The results were compared with those obtained using uncorrected reconstruction (i.e., using same raw data but without motion or field correction).
Results
Our motion‐corrected reconstruction largely improved image quality for fMRI time series, reducing motion confounds when compared with uncorrected reconstruction. The reduction in motion confounds translated into an improvement in tSNR, with tSNR averaged across all volunteers being increased by about 11%. Our motion‐corrected reconstruction also improved both amplitude of low‐frequency fluctuation and regional homogeneity in most cortical surfaces and subcortical regions.
Conclusion
It is feasible to perform quality three‐dimensional whole‐brain blood oxygen level–dependent fMRI in humans at 10.5 T using a new comprehensive motion‐robust imaging method. This work paves the way for promising future applications at 10.5 T aimed at studying brain function and networks with high spatiotemporal resolution.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Center for Magnetic Resonance Research, Radiology, Medical School, University of Minnesota Twin Cities, Minneapolis, Minnesota, USA.
- Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, Texas, USA.
- Radiology, UT Southwestern Medical Center, Dallas, Texas, USA.
- Advanced MRI section, NINDS, NIH, Bethesda, Maryland, USA.
ORCID-Profile: Shuxian Qu, Jiaen Liu, Jacco A de Zwart, Matt Waks, Russell Lagore, Edward Auerbach, Alireza Sadeghi-Tarakameh, Gregor Adriany, Kamil Ugurbil, Xiaoping Wu
Förderung
- NIBIB NIH HHS
- NCRR NIH HHS
- NINDS, NIH
- NINDS NIH HHS
- Hamon Foundation
- Texas Instrument Foundation
- National Institute of Neurological Disorders and Stroke
Zitieren
APA
Qu, S., Liu, J., van Gelderen, P., de Zwart, J. A., Duyn, J. H., Waks, M., Lagore, R., Bratch, A., Grant, A., Auerbach, E., Delabarre, L., Sadeghi-Tarakameh, A., Eryaman, Y., Adriany, G., Ugurbil, K., & Wu, X. (2026). Advancing whole‐brain BOLD functional MRI in humans at 10.5 T with motion‐robust 3D echo‐planar imaging , parallel transmission, and high‐density radiofrequency receive coils. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70110
Vancouver
Qu S, Liu J, van Gelderen P, de Zwart JA, Duyn JH, Waks M, et al. Advancing whole‐brain BOLD functional MRI in humans at 10.5 T with motion‐robust 3D echo‐planar imaging , parallel transmission, and high‐density radiofrequency receive coils. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70110
BibTeX
@article{Qu2026,
author = {Qu, Shuxian and Liu, Jiaen and van Gelderen, Peter and de Zwart, Jacco A and Duyn, Jeff H and Waks, Matt and Lagore, Russell and Bratch, Alexander and Grant, Andrea and Auerbach, Edward and Delabarre, Lance and Sadeghi-Tarakameh, Alireza and Eryaman, Yigitcan and Adriany, Gregor and Ugurbil, Kamil and Wu, Xiaoping},
title = {Advancing whole‐brain BOLD functional MRI in humans at 10.5 T with motion‐robust 3D echo‐planar imaging , parallel transmission, and high‐density radiofrequency receive coils},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70110}
}
EUVIMED