Non-Cartesian 3D-SPARKLING vs Cartesian 3D-EPI encoding schemes for functional Magnetic Resonance Imaging at 7 Tesla
PLOS ONE · 2024
DOI: 10.1371/journal.pone.0299925 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, 2024. Verfasst von Zaineb Amor und 6 weiteren Autor:innen. Beteiligte Einrichtung: CEA, Joliot, NeuroSpin, Université Paris-Saclay, Gif-sur-Yvette, France. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Brain Mapping, Imaging, Three-Dimensional, Brain. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 88 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: H2020 Marie Skłodowska-Curie Actions, Fondation Leducq.
Abstract (Originalsprache)
The quest for higher spatial and/or temporal resolution in functional MRI (fMRI) while preserving a sufficient temporal signal-to-noise ratio (tSNR) has generated a tremendous amount of methodological contributions in the last decade ranging from Cartesian vs. non-Cartesian readouts, 2D vs. 3D acquisition strategies, parallel imaging and/or compressed sensing (CS) accelerations and simultaneous multi-slice acquisitions to cite a few. In this paper, we investigate the use of a finely tuned version of 3D-SPARKLING. This is a non-Cartesian CS-based acquisition technique for high spatial resolution whole-brain fMRI. We compare it to state-of-the-art Cartesian 3D-EPI during both a retinotopic mapping paradigm and resting-state acquisitions at 1mm 3 (isotropic spatial resolution). This study involves six healthy volunteers and both acquisition sequences were run on each individual in a randomly-balanced order across subjects. The performances of both acquisition techniques are compared to each other in regards to tSNR, sensitivity to the BOLD effect and spatial specificity. Our findings reveal that 3D-SPARKLING has a higher tSNR than 3D-EPI, an improved sensitivity to detect the BOLD contrast in the gray matter, and an improved spatial specificity. Compared to 3D-EPI, 3D-SPARKLING yields, on average, 7% more activated voxels in the gray matter relative to the total number of activated voxels.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- CEA, Joliot, NeuroSpin, Université Paris-Saclay, Gif-sur-Yvette, France.
- Inria, MIND team, Université Paris-Saclay, Palaiseau, France.
- Siemens Heathineers, Courbevoie, France.
ORCID-Profile: Zaineb Amor, Franck Mauconduit, Bertrand Thirion
Förderung
- H2020 Marie Skłodowska-Curie Actions
- Fondation Leducq
Zitieren
APA
Amor, Z., Ciuciu, P., G R, C., Daval-Frérot, G., Mauconduit, F., Thirion, B., & Vignaud, A. (2024). Non-Cartesian 3D-SPARKLING vs Cartesian 3D-EPI encoding schemes for functional Magnetic Resonance Imaging at 7 Tesla. PLOS ONE. https://doi.org/10.1371/journal.pone.0299925
Vancouver
Amor Z, Ciuciu P, G R C, Daval-Frérot G, Mauconduit F, Thirion B, et al. Non-Cartesian 3D-SPARKLING vs Cartesian 3D-EPI encoding schemes for functional Magnetic Resonance Imaging at 7 Tesla. PLOS ONE. 2024. doi:10.1371/journal.pone.0299925
BibTeX
@article{Amor2024,
author = {Amor, Zaineb and Ciuciu, Philippe and G R, Chaithya and Daval-Frérot, Guillaume and Mauconduit, Franck and Thirion, Bertrand and Vignaud, Alexandre},
title = {Non-Cartesian 3D-SPARKLING vs Cartesian 3D-EPI encoding schemes for functional Magnetic Resonance Imaging at 7 Tesla},
journal = {PLOS ONE},
year = {2024},
doi = {10.1371/journal.pone.0299925}
}
EUVIMED