EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Design and performance of a toroidal radiofrequency volume coil with intrinsic electromagnetic interference rejection for low‐field portable Halbach‐based MRI systems

Jules Vliem iD, Chloe Najac iD, Beatrice Lena iD, Andrew Webb, Irena Zivkovic iD

Magnetic Resonance in Medicine · 2026

DOI: 10.1002/mrm.70095 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Jules Vliem und 4 weiteren Autor:innen. Beteiligte Einrichtung: Electrical Engineering Department, Eindhoven University of Technology, Eindhoven, The Netherlands. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Dutch Growth Fund program POLARIS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

One of the intrinsic limitations of low‐field MRI is low signal‐to‐noise ratio, which can be further reduced by electromagnetic interference (EMI) due to the lack of a Faraday shielded room. To address this issue, we propose a novel radiofrequency (RF) coil design that is inherently less sensitive to EMI while maintaining high receive sensitivity.

Methods

The proposed coil structure is based on an anapole (toroidal) design and consists of six rings, each containing four continuous wires wound around an elliptical three‐dimensional‐printed former. The wire in the entire structure is uninterrupted. This coil is designed for use in systems with an axial B 0 field direction. The performance of the proposed RF coil was evaluated on a Halbach array system designed for neuroimaging and operating at 47 mT and compared with a widely used spiral head coil.

Results

The noise level achieved by the proposed toroidal coil in combination with a belt wrapped around the subjects and grounded to the scanner was comparable to that of the widely used spiral head coil when combined with a grounding belt and passive aluminum shielding. The coil transmit and receive efficiency was comparable to the efficiency of the spiral head coil.

Conclusion

The proposed RF coil inherently reduces the effect of EMI, potentially removing or reducing the need for passive shielding or external/internal sensors for EMI reduction in postprocessing.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingEquipment DesignHumansSignal-To-Noise RatioPhantoms, ImagingRadio WavesElectromagnetic FieldsImage Processing, Computer-AssistedBrainNeuroimagingHead

Stichwörter der Autor:innen

RF coillow‐field MRIneuroimagingnoise rejection coilportable MRIvolume coil

Autor:innen und Institutionen

  • Electrical Engineering Department, Eindhoven University of Technology, Eindhoven, The Netherlands.
  • C.J. Gorter MRI Center, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands.

ORCID-Profile: Jules Vliem, Chloe Najac, Beatrice Lena, Irena Zivkovic

Förderung

  • Dutch Growth Fund program POLARIS

Zitieren

APA

Vliem, J., Najac, C., Lena, B., Webb, A., & Zivkovic, I. (2026). Design and performance of a toroidal radiofrequency volume coil with intrinsic electromagnetic interference rejection for low‐field portable Halbach‐based MRI systems. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70095

Vancouver

Vliem J, Najac C, Lena B, Webb A, Zivkovic I. Design and performance of a toroidal radiofrequency volume coil with intrinsic electromagnetic interference rejection for low‐field portable Halbach‐based MRI systems. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70095

BibTeX
@article{Vliem2026,
  author = {Vliem, Jules and Najac, Chloe and Lena, Beatrice and Webb, Andrew and Zivkovic, Irena},
  title = {Design and performance of a toroidal radiofrequency volume coil with intrinsic electromagnetic interference rejection for low‐field portable Halbach‐based MRI systems},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70095}
}
Kostenlos starten →