FENCE: Flexible Electric Noise Reduction Endo‐Shield for the Suppression of Electromagnetic Interference in Low‐Field MRI
NMR in Biomedicine · 2026
DOI: 10.1002/nbm.70287 ↗Kurz gefasst
Fachartikel in der Zeitschrift NMR in Biomedicine, 2026. Verfasst von Julia Pfitzer und 2 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Biomedical Imaging, Graz University of Technology, Graz, Austria. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Signal-To-Noise Ratio, Electromagnetic Fields, Artifacts. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Electromagnetic interference (EMI) is a significant challenge for low‐field MRI systems operating without conventional Faraday‐shielded rooms. This interference degrades image quality and limits deployment in space‐constrained or electromagnetically noisy environments. Traditional EMI mitigation approaches include external shields, subject grounding via electrodes, or active noise cancellation requiring synchronized receive channels. These methods either limit portability, introduce patient discomfort, or demand advanced hardware. In this work, we start from the hypothesis that EMI primarily couples capacitively from the body to the RF coil. We investigated two methods of blocking capacitive coupling while preserving inductive MRI signal detection: First, we employed capacitive segmentation of the RF coil and studied its effect on EMI coupling. Second, we present FENCE (Flexible Electromagnetic Noise reduCtion Endo‐shield), a novel approach blocking capacitive coupling using flexible PCB shields placed inside the RF coil. FENCE can be retrofitted to existing RF coils without significant mechanical modifications. Finite element (FE) simulations were used to estimate the expected shielding performance and the impact on RF coil losses prior to practical implementation. Testing in various scenarios then demonstrated that the combination of FENCE with segmented solenoid coils is effective against both environmental noise sources and controlled EMI. In phantom experiments, FENCE significantly improved imaging performance and reduced EMI levels to near‐baseline levels with 9% reduction in coil quality factor (Q factor), showing good agreement with the predictions from the FE simulations. In vivo head imaging confirmed these results across diverse electromagnetic environments significantly improving imaging performance while showing an 18% decrease in Q factor. FENCE provides a simple method for EMI mitigation in low‐field MRI, enhancing image quality while maintaining system portability and accessibility. This approach could help to expand the deployment of low‐field MRI systems in low‐cost point‐of‐care applications where conventional shielding is impractical.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Biomedical Imaging, Graz University of Technology, Graz, Austria.
- BioTechMed-Graz, Graz, Austria.
ORCID-Profile: Julia Pfitzer
Zitieren
APA
Pfitzer, J., Uecker, M., & Scharfetter, H. (2026). FENCE: Flexible Electric Noise Reduction Endo‐Shield for the Suppression of Electromagnetic Interference in Low‐Field MRI. NMR in Biomedicine. https://doi.org/10.1002/nbm.70287
Vancouver
Pfitzer J, Uecker M, Scharfetter H. FENCE: Flexible Electric Noise Reduction Endo‐Shield for the Suppression of Electromagnetic Interference in Low‐Field MRI. NMR in Biomedicine. 2026. doi:10.1002/nbm.70287
BibTeX
@article{Pfitzer2026,
author = {Pfitzer, Julia and Uecker, Martin and Scharfetter, Hermann},
title = {FENCE: Flexible Electric Noise Reduction Endo‐Shield for the Suppression of Electromagnetic Interference in Low‐Field MRI},
journal = {NMR in Biomedicine},
year = {2026},
doi = {10.1002/nbm.70287}
}
EUVIMED