Self‐Gated Radial Free‐Breathing Liver MR Elastography: Assessment of Technical Performance in Children at 3 T
Journal of Magnetic Resonance Imaging · 2025
DOI: 10.1002/jmri.29541 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, 2025. Verfasst von Sevgi Gokce Kafali und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiological Sciences, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, California, USA. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques, Liver, Magnetic Resonance Imaging. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCATS NIH HHS, NIDDK NIH HHS, NIBIB NIH HHS.
Themen: Kinderkrankenpflege
Abstract (Originalsprache)
Background
Conventional liver magnetic resonance elastography (MRE) requires breath‐holding (BH) to avoid motion artifacts, which is challenging for children. While radial free‐breathing (FB)‐MRE is an alternative for quantifying liver stiffness (LS), previous methods had limitations of long scan times, acquiring two slices in 5 minutes, and not resolving motion during reconstruction.
Purpose
To reduce FB‐MRE scan time to 4 minutes for four slices and to investigate the impact of self‐gated (SG) motion compensation on FB‐MRE LS quantification in terms of agreement, intrasession repeatability, and technical quality compared to conventional BH‐MRE. Study Type Prospective. Population Twenty‐six children without fibrosis (median age: 12.9 years, 15 females). Field Strength/Sequence 3 T; Cartesian gradient‐echo (GRE) BH‐MRE, research application radial GRE FB‐MRE. Assessment Participants were scanned twice to measure repeatability, without moving the table or changing the participants' position. LS was measured in areas of the liver with numerical confidence ≥90%. Technical quality was examined using measurable liver area (%). Statistical Tests Agreement of LS between BH‐MRE and FB‐MRE was evaluated using Bland–Altman analysis for SG acceptance rates of 40%, 60%, 80%, and 100%. LS repeatability was assessed using within‐subject coefficient of variation (wCV). The differences in LS and measurable liver area were examined using Kruskal–Wallis and Wilcoxon signed‐rank tests. P < 0.05 was considered significant.
Results
FB‐MRE with 60% SG achieved the closest agreement with BH‐MRE (mean difference 0.00 kPa). The LS ranged from 1.70 to 1.83 kPa with no significant differences between BH‐MRE and FB‐MRE with varying SG rates ( P = 0.52). All tested methods produced repeatable LS with wCV from 4.4% to 6.5%. The median measurable liver area was smaller for FB‐MRE (32%–45%) than that for BH‐MRE (91%–93%) ( P < 0.05). Data Conclusion FB‐MRE with 60% SG can quantify LS with close agreement and comparable repeatability with respect to BH‐MRE in children. Level of Evidence 2 Technical Efficacy Stage 1
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiological Sciences, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, California, USA.
- Department of Bioengineering, University of California Los Angeles, Los Angeles, California, USA.
- US MR R&D Collaborations, Siemens Medical Solutions USA, Inc., Salt Lake City, Utah, USA.
- Physics and Biology in Medicine Interdepartmental Program, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, California, USA.
- US MR R&D Collaborations, Siemens Medical Solutions USA, Inc., Austin, Texas, USA.
- Department of Pediatrics, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, California, USA.
ORCID-Profile: Sevgi Gokce Kafali, Bradley D Bolster, Shu-Fu Shih, Xiaodong Zhong, Holden H Wu
Förderung
- NCATS NIH HHS
- NIDDK NIH HHS
- NIBIB NIH HHS
- National Institute of Diabetes and Digestive and Kidney Diseases
- National Institute of Biomedical Imaging and Bioengineering
- National Center for Advancing Translational Sciences
Zitieren
APA
Kafali, S. G., Bolster, B. D., Shih, S. F., Delgado, T. I., Deshpande, V., Zhong, X., Adamos, T. R., Ghahremani, S., Calkins, K. L., & Wu, H. H. (2025). Self‐Gated Radial Free‐Breathing Liver MR Elastography: Assessment of Technical Performance in Children at 3 T. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.29541
Vancouver
Kafali SG, Bolster BD, Shih SF, Delgado TI, Deshpande V, Zhong X, et al. Self‐Gated Radial Free‐Breathing Liver MR Elastography: Assessment of Technical Performance in Children at 3 T. Journal of Magnetic Resonance Imaging. 2025. doi:10.1002/jmri.29541
BibTeX
@article{Kafali2025,
author = {Kafali, Sevgi Gokce and Bolster, Bradley D and Shih, Shu-Fu and Delgado, Timoteo I and Deshpande, Vibhas and Zhong, Xiaodong and Adamos, Timothy R and Ghahremani, Shahnaz and Calkins, Kara L and Wu, Holden H},
title = {Self‐Gated Radial Free‐Breathing Liver MR Elastography: Assessment of Technical Performance in Children at 3 T},
journal = {Journal of Magnetic Resonance Imaging},
year = {2025},
doi = {10.1002/jmri.29541}
}
EUVIMED