EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

B 0 ‐insensitive image navigators for prospective motion‐corrected MRS with localized second‐order shimming

Isaac M Adanyeguh iD, Young Woo Park, Pierre-Gilles Henry, Dinesh K Deelchand iD

Magnetic Resonance in Medicine · 2024

DOI: 10.1002/mrm.30151 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Isaac M Adanyeguh und 3 weiteren Autor:innen. Beteiligte Einrichtung: Center for Magnetic Resonance Research and Department of Radiology, University of Minnesota Medical School, Minneapolis, Minnesota, USA. Hauptthemen laut MEDLINE: Motion, Algorithms. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIBIB NIH HHS, NIH HHS, NINDS NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Localized shimming in single‐voxel MRS often results in large B 0 inhomogeneity outside the volume‐of‐interest. This causes unacceptable degradation in motion navigator images. Switching back and forth between whole‐brain shim and localized shim is possible for linear shims, but not for higher‐order shims. Here we propose motion navigators largely insensitive to B 0 inhomogeneity for prospective motion‐corrected MRS with localized higher‐order shimming.

Methods

A recent fast high‐resolution motion navigator based on spiral‐in/out k‐space trajectories and multislice‐to‐volume registration was modified by splitting the readout into multiple shot interleaves which shortened the echo time and reduced the effect of B 0 inhomogeneity. The performance of motion correction was assessed in healthy subjects in the prefrontal cortex using a sLASER sequence at 3T ( N = 5) and 7T ( N = 5).

Results

With multiple spatial interleaves, excellent quality navigator images were acquired in the whole brain in spite of large B 0 inhomogeneity outside the MRS voxel. The total duration of the navigator in sLASER remained relatively short even with multiple shots (3T: 10 spatial interleaves 94 ms per slice; 7T: 15 spatial interleaves 103 ms per slice). Prospective motion correction using the multi‐shot navigators yielded comparable spectral quality (water linewidth and metabolite SNR) with and without subject motion.

Conclusion

B 0 ‐insensitive motion navigators enable prospective motion correction for MRS with all first‐ and second‐order shims adjusted in the MRS voxel, providing optimal spectral linewidth.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MotionAlgorithmsHumansMagnetic Resonance SpectroscopyBrainMagnetic Resonance ImagingImage Processing, Computer-AssistedArtifactsMaleAdultFemaleReproducibility of ResultsPrefrontal CortexSensitivity and Specificity

Stichwörter der Autor:innen

brainhigh‐fieldprospective motion‐correctionspectroscopy

Autor:innen und Institutionen

  • Center for Magnetic Resonance Research and Department of Radiology, University of Minnesota Medical School, Minneapolis, Minnesota, USA.

ORCID-Profile: Isaac M Adanyeguh, Dinesh K Deelchand

Förderung

  • NIBIB NIH HHS
  • NIH HHS
  • NINDS NIH HHS
  • National Institutes of Health

Zitieren

APA

Adanyeguh, I. M., Park, Y. W., Henry, P. G., & Deelchand, D. K. (2024). B 0 ‐insensitive image navigators for prospective motion‐corrected MRS with localized second‐order shimming. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30151

Vancouver

Adanyeguh IM, Park YW, Henry PG, Deelchand DK. B 0 ‐insensitive image navigators for prospective motion‐corrected MRS with localized second‐order shimming. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30151

BibTeX
@article{Adanyeguh2024,
  author = {Adanyeguh, Isaac M and Park, Young Woo and Henry, Pierre-Gilles and Deelchand, Dinesh K},
  title = {B 0 ‐insensitive image navigators for prospective motion‐corrected MRS with localized second‐order shimming},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.30151}
}
Kostenlos starten →