Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Peter J Lally und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Bioengineering, Imperial College London, London, UK. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Echo-Planar Imaging, Image Processing, Computer-Assisted, Image Interpretation, Computer-Assisted. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS, UK Dementia Research Institute, Wellcome Trust.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Multi‐echo gradient echo imaging is useful for a range of applications including relaxometry, susceptibility mapping, and quantifying relative proportions of fat and water. This relies primarily on long‐TR multi‐echo gradient echo sequences (FLASH), which by design isolate one signal component (i.e., echo) at a time per readout. In this work, we propose an alternative strategy that simultaneously measures all signal components at once in every readout event with an N‐periodic SSFP sequence. Essentially, we Fourier encode the signals into an “F‐k space” similar to the “TE‐k space” of a multi‐echo gradient echo acquisition. This enables an efficient, short‐TR relaxometry experiment where signals benefit from averaging effects over multiple excitations. Theory and Methods In the presented approach, multiple echoes are recorded simultaneously and separated by their differing phase evolution over multiple TRs. At low flip angles the relative echo amplitudes and phases are equivalent to those acquired sequentially from a multi‐echo FLASH, in terms of both T 2 * weighting and spatial phase distributions. The two approaches were compared for the example of R 2 * relaxometry in a phantom and in human volunteers.

Results

The proposed approach shows close agreement in R 2 * estimation with multi‐echo FLASH, with the advantage of more rapid temporal sampling.

Conclusion

The proposed approach is a promising alternative to other relaxometry approaches, by measuring signals from multiple echo pathways simultaneously and separating them based on a simple analytical model.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingEcho-Planar ImagingImage Processing, Computer-AssistedImage Interpretation, Computer-AssistedHumansAlgorithmsPhantoms, ImagingFourier AnalysisReproducibility of ResultsSignal Processing, Computer-AssistedImage EnhancementSensitivity and Specificity

Stichwörter der Autor:innen

FLASHOSSISSFPT2*

Autor:innen und Institutionen

  • Department of Bioengineering, Imperial College London, London, UK.
  • Centre for Care Research and Technology, UK Dementia Research Institute, London, UK.
  • London Collaborative Ultra-high field System (LoCUS), London, UK.
  • Medical Biophysics, University of Toronto, Toronto, Ontario, Canada.
  • Physical Sciences, Sunnybrook Research Institute, Toronto, Ontario, Canada.
  • Department of Brain Sciences, Imperial College London, London, UK.

ORCID-Profile: Peter J Lally, Zimu Huo, Mark Chiew

Förderung

  • NIBIB NIH HHS
  • UK Dementia Research Institute
  • Wellcome Trust
  • NIHR Imperial Biomedical Research Centre
  • National Institute of Biomedical Imaging and Bioengineering

Zitieren

APA

Lally, P. J., Jin, Y., Huo, Z., Beitone, C., Chiew, M., Matthews, P. M., Miller, K. L., & Bangerter, N. K. (2025). Steady‐state free precession for T 2 * relaxometry: All echoes in every readout with k‐space aliasing. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30590

Vancouver

Lally PJ, Jin Y, Huo Z, Beitone C, Chiew M, Matthews PM, et al. Steady‐state free precession for T 2 * relaxometry: All echoes in every readout with k‐space aliasing. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30590

BibTeX
@article{Lally2025,
  author = {Lally, Peter J and Jin, Yifei and Huo, Zimu and Beitone, Coraline and Chiew, Mark and Matthews, Paul M and Miller, Karla L and Bangerter, Neal K},
  title = {Steady‐state free precession for T 2 * relaxometry: All echoes in every readout with k‐space aliasing},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30590}
}
Kostenlos starten →