Steady‐state free precession for T 2 * relaxometry: All echoes in every readout with k‐space aliasing
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30590 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Peter J Lally und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Bioengineering, Imperial College London, London, UK. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Echo-Planar Imaging, Image Processing, Computer-Assisted, Image Interpretation, Computer-Assisted. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS, UK Dementia Research Institute, Wellcome Trust.
Abstract (Originalsprache)
Purpose
Multi‐echo gradient echo imaging is useful for a range of applications including relaxometry, susceptibility mapping, and quantifying relative proportions of fat and water. This relies primarily on long‐TR multi‐echo gradient echo sequences (FLASH), which by design isolate one signal component (i.e., echo) at a time per readout. In this work, we propose an alternative strategy that simultaneously measures all signal components at once in every readout event with an N‐periodic SSFP sequence. Essentially, we Fourier encode the signals into an “F‐k space” similar to the “TE‐k space” of a multi‐echo gradient echo acquisition. This enables an efficient, short‐TR relaxometry experiment where signals benefit from averaging effects over multiple excitations. Theory and Methods In the presented approach, multiple echoes are recorded simultaneously and separated by their differing phase evolution over multiple TRs. At low flip angles the relative echo amplitudes and phases are equivalent to those acquired sequentially from a multi‐echo FLASH, in terms of both T 2 * weighting and spatial phase distributions. The two approaches were compared for the example of R 2 * relaxometry in a phantom and in human volunteers.
Results
The proposed approach shows close agreement in R 2 * estimation with multi‐echo FLASH, with the advantage of more rapid temporal sampling.
Conclusion
The proposed approach is a promising alternative to other relaxometry approaches, by measuring signals from multiple echo pathways simultaneously and separating them based on a simple analytical model.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Bioengineering, Imperial College London, London, UK.
- Centre for Care Research and Technology, UK Dementia Research Institute, London, UK.
- London Collaborative Ultra-high field System (LoCUS), London, UK.
- Medical Biophysics, University of Toronto, Toronto, Ontario, Canada.
- Physical Sciences, Sunnybrook Research Institute, Toronto, Ontario, Canada.
- Department of Brain Sciences, Imperial College London, London, UK.
ORCID-Profile: Peter J Lally, Zimu Huo, Mark Chiew
Förderung
- NIBIB NIH HHS
- UK Dementia Research Institute
- Wellcome Trust
- NIHR Imperial Biomedical Research Centre
- National Institute of Biomedical Imaging and Bioengineering
Zitieren
APA
Lally, P. J., Jin, Y., Huo, Z., Beitone, C., Chiew, M., Matthews, P. M., Miller, K. L., & Bangerter, N. K. (2025). Steady‐state free precession for T 2 * relaxometry: All echoes in every readout with k‐space aliasing. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30590
Vancouver
Lally PJ, Jin Y, Huo Z, Beitone C, Chiew M, Matthews PM, et al. Steady‐state free precession for T 2 * relaxometry: All echoes in every readout with k‐space aliasing. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30590
BibTeX
@article{Lally2025,
author = {Lally, Peter J and Jin, Yifei and Huo, Zimu and Beitone, Coraline and Chiew, Mark and Matthews, Paul M and Miller, Karla L and Bangerter, Neal K},
title = {Steady‐state free precession for T 2 * relaxometry: All echoes in every readout with k‐space aliasing},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30590}
}
EUVIMED