Cartesian MaxGIRF : Model‐based EPI reconstruction incorporating gradient nonlinearity and concomitant field effects
Magnetic Resonance in Medicine · 2026
DOI: 10.1002/mrm.70113 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Nam G Lee und 2 weiteren Autor:innen. Beteiligte Einrichtung: Alfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, California, USA. Hauptthemen laut MEDLINE: Image Processing, Computer-Assisted, Brain, Echo-Planar Imaging. Die Arbeit nennt 98 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Division of Computing and Communication Foundations, NIAMS NIH HHS, NHLBI NIH HHS.
Abstract (Originalsprache)
Purpose
Lower field strength scanners with large bore size or complex geometries, and scanners with stronger gradient systems experience increased gradient nonlinearity and concomitant fields, each of which causes distortions in EPI. Current correction approaches based on image‐domain interpolation introduce undesirable spatial blurring. To avoid spatial blurring, we introduce a model‐based EPI reconstruction framework, denoted Cartesian MaxGIRF (“Max”well field correction using “GIRF”‐predicted gradients), that simultaneously compensates the effects of concomitant fields, gradient nonlinearity, and off‐resonance during image reconstruction. Theory and Methods Performance of the proposed framework was compared against standard correction methods using phantom datasets at 0.55T: (1) 2D spin‐echo EPI (SE‐EPI) with reversed phase‐encoding directions and (2) accelerated 2D SE‐EPI with partial Fourier. Two unique EPI image artifacts induced by concomitant fields (“parabolic shift” and “slice‐dependent Nyquist ghost”) were demonstrated and mitigated by the proposed framework using long‐ETL 3D GRE‐EPI and high‐resolution 3D GRE‐EPI, respectively. Resolution improvements and artifact mitigations by the proposed framework were demonstrated using in‐vivo human brain datasets: (1) accelerated 2D diffusion‐weighted SE‐EPI and (2) high‐resolution 3D GRE‐EPI at 0.55T.
Results
The amount of the parabolic shift for each imaging case was theoretically analyzed. The proposed framework demonstrated the mitigation of both parabolic shifts and slice‐dependent Nyquist ghosts and retained better image details than standard correction methods when mitigating geometric distortions for all scenarios.
Conclusion
The Cartesian MaxGIRF framework simultaneously mitigates the effects of concomitant fields, gradient nonlinearity, and static off‐resonance. This approach is particularly useful to mitigate artifacts induced by second‐order concomitant fields present in both symmetric and asymmetric gradient systems.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Alfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, California, USA.
- Siemens Medical Solutions USA, Los Angeles, California, USA.
- Ming Hsieh Department of Electrical and Computer Engineering, University of Southern California, Los Angeles, California, USA.
ORCID-Profile: Nam G Lee, Sophia X Cui, Krishna S Nayak
Förderung
- Division of Computing and Communication Foundations
- NIAMS NIH HHS
- NHLBI NIH HHS
- National Heart and Lung Institute
- National Institute of Arthritis and Musculoskeletal and Skin Diseases
Zitieren
APA
Lee, N. G., Cui, S. X., & Nayak, K. S. (2026). Cartesian MaxGIRF : Model‐based EPI reconstruction incorporating gradient nonlinearity and concomitant field effects. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70113
Vancouver
Lee NG, Cui SX, Nayak KS. Cartesian MaxGIRF : Model‐based EPI reconstruction incorporating gradient nonlinearity and concomitant field effects. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70113
BibTeX
@article{Lee2026,
author = {Lee, Nam G and Cui, Sophia X and Nayak, Krishna S},
title = {Cartesian MaxGIRF : Model‐based EPI reconstruction incorporating gradient nonlinearity and concomitant field effects},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70113}
}
EUVIMED