EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Partial Fourier in the presence of respiratory motion in prostate diffusion-weighted echo planar imaging

Sean McTavish, Anh T Van, Johannes M Peeters, Kilian Weiss, Felix N Harder, Marcus R Makowski, Rickmer F Braren, Dimitrios C Karampinos

Magnetic Resonance Materials in Physics, Biology and Medicine · 2024

DOI: 10.1007/s10334-024-01162-x ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Materials in Physics, Biology and Medicine, 2024. Verfasst von Sean McTavish und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology, School of Medicine, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany…. Hauptthemen laut MEDLINE: Diffusion Magnetic Resonance Imaging, Fourier Analysis, Echo-Planar Imaging, Prostate. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 74 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Philips Medical Systems, Technische Universität München.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To investigate the effect of respiratory motion in terms of signal loss in prostate diffusion-weighted imaging (DWI), and to evaluate the usage of partial Fourier in a free-breathing protocol in a clinically relevant b -value range using both single-shot and multi-shot acquisitions.

Methods

A controlled breathing DWI acquisition was first employed at 3 T to measure signal loss from deep breathing patterns. Single-shot and multi-shot (2-shot) acquisitions without partial Fourier (no pF) and with partial Fourier (pF) factors of 0.75 and 0.65 were employed in a free-breathing protocol. The apparent SNR and ADC values were evaluated in 10 healthy subjects to measure if low pF factors caused low apparent SNR or overestimated ADC.

Results

Controlled breathing experiments showed a difference in signal coefficient of variation between shallow and deep breathing. In free-breathing single-shot acquisitions, the pF 0.65 scan showed a significantly ( p < 0.05) higher apparent SNR than pF 0.75 and no pF in the peripheral zone (PZ) of the prostate. In the multi-shot acquisitions in the PZ, pF 0.75 had a significantly higher apparent SNR than 0.65 pF and no pF. The single-shot pF 0.65 scan had a significantly lower ADC than single-shot no pF.

Conclusion

Deep breathing patterns can cause intravoxel dephasing in prostate DWI. For single-shot acquisitions at a b -value of 800 s/mm 2 , any potential risks of motion-related artefacts at low pF factors (pF 0.65) were outweighed by the increase in signal from a lower TE, as shown by the increase in apparent SNR. In multi-shot acquisitions however, the minimum pF factor should be larger, as shown by the lower apparent SNR at low pF factors.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Diffusion Magnetic Resonance ImagingFourier AnalysisEcho-Planar ImagingProstateRespirationSignal-To-Noise RatioMotionHumansMaleAdultProstatic NeoplasmsImage Processing, Computer-AssistedArtifactsAlgorithmsMiddle AgedImage Interpretation, Computer-Assisted

Stichwörter der Autor:innen

Apparent diffusion coefficient (ADC) mappingDiffusion-weighted imagingMulti-shot EPIProstate imagingSingle-shot echo planar imaging (EPI)

Autor:innen und Institutionen

  • Department of Diagnostic and Interventional Radiology, School of Medicine, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany. sean.mctavish@tum.de.
  • Department of Diagnostic and Interventional Radiology, School of Medicine, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany.
  • Philips Healthcare, Best, Netherlands.
  • Philips GmbH, Hamburg, Germany.

Förderung

  • Philips Medical Systems
  • Technische Universität München

Zitieren

APA

McTavish, S., Van, A. T., Peeters, J. M., Weiss, K., Harder, F. N., Makowski, M. R., Braren, R. F., & Karampinos, D. C. (2024). Partial Fourier in the presence of respiratory motion in prostate diffusion-weighted echo planar imaging. Magnetic Resonance Materials in Physics, Biology and Medicine. https://doi.org/10.1007/s10334-024-01162-x

Vancouver

McTavish S, Van AT, Peeters JM, Weiss K, Harder FN, Makowski MR, et al. Partial Fourier in the presence of respiratory motion in prostate diffusion-weighted echo planar imaging. Magnetic Resonance Materials in Physics, Biology and Medicine. 2024. doi:10.1007/s10334-024-01162-x

BibTeX
@article{McTavish2024,
  author = {McTavish, Sean and Van, Anh T and Peeters, Johannes M and Weiss, Kilian and Harder, Felix N and Makowski, Marcus R and Braren, Rickmer F and Karampinos, Dimitrios C},
  title = {Partial Fourier in the presence of respiratory motion in prostate diffusion-weighted echo planar imaging},
  journal = {Magnetic Resonance Materials in Physics, Biology and Medicine},
  year = {2024},
  doi = {10.1007/s10334-024-01162-x}
}