EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A shielded 32‐channel body transceiver array with integrated electronics for 7 T

Tobey D Haluptzok iD, Russell L Lagore iD, Simon Schmidt iD, Gregory J Metzger iD

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.30498 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Tobey D Haluptzok und 3 weiteren Autor:innen. Beteiligte Einrichtung: Center for Magnetic Resonance Research (CMRR), University of Minnesota, Minneapolis, Minnesota, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS, National Institute of Biomedical Imaging and Bioengineering.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Develop a 32‐channel transceiver array for 7 T body imaging that incorporates an RF shield, improves SNR, lowers g‐factors, and is robust to external loading.

Methods

The addition of a local RF shield was first investigated for single resonant blocks consisting of either one loop and a dipole (LD) or three loops and a dipole (3LD). A 32‐channel array consisting of eight shielded 3LD blocks (32LD‐SH) was constructed and validated for in‐vivo use. The SNR, parallel imaging, and transmit performance were compared to a previously published 16‐channel LD array (16LD). The effect of top loading was investigated by placing arms on top of the coils and measuring S‐parameter changes. In vivo imaging of multiple anatomies was performed.

Results

In single block experiments, the RF shield impacted SNR and performance by

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingHumansEquipment DesignPhantoms, ImagingSignal-To-Noise RatioRadio WavesImage Processing, Computer-AssistedElectronics

Stichwörter der Autor:innen

7 TRF shieldUHF MRIbody imagingloop dipoletransceiver array

Autor:innen und Institutionen

  • Center for Magnetic Resonance Research (CMRR), University of Minnesota, Minneapolis, Minnesota, USA.

ORCID-Profile: Tobey D Haluptzok, Russell L Lagore, Simon Schmidt, Gregory J Metzger

Förderung

  • NIBIB NIH HHS
  • National Institute of Biomedical Imaging and Bioengineering

Zitieren

APA

Haluptzok, T. D., Lagore, R. L., Schmidt, S., & Metzger, G. J. (2025). A shielded 32‐channel body transceiver array with integrated electronics for 7 T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30498

Vancouver

Haluptzok TD, Lagore RL, Schmidt S, Metzger GJ. A shielded 32‐channel body transceiver array with integrated electronics for 7 T. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30498

BibTeX
@article{Haluptzok2025,
  author = {Haluptzok, Tobey D and Lagore, Russell L and Schmidt, Simon and Metzger, Gregory J},
  title = {A shielded 32‐channel body transceiver array with integrated electronics for 7 T},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30498}
}
Kostenlos starten →