A shielded 32‐channel body transceiver array with integrated electronics for 7 T
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30498 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Tobey D Haluptzok und 3 weiteren Autor:innen. Beteiligte Einrichtung: Center for Magnetic Resonance Research (CMRR), University of Minnesota, Minneapolis, Minnesota, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS, National Institute of Biomedical Imaging and Bioengineering.
Abstract (Originalsprache)
Purpose
Develop a 32‐channel transceiver array for 7 T body imaging that incorporates an RF shield, improves SNR, lowers g‐factors, and is robust to external loading.
Methods
The addition of a local RF shield was first investigated for single resonant blocks consisting of either one loop and a dipole (LD) or three loops and a dipole (3LD). A 32‐channel array consisting of eight shielded 3LD blocks (32LD‐SH) was constructed and validated for in‐vivo use. The SNR, parallel imaging, and transmit performance were compared to a previously published 16‐channel LD array (16LD). The effect of top loading was investigated by placing arms on top of the coils and measuring S‐parameter changes. In vivo imaging of multiple anatomies was performed.
Results
In single block experiments, the RF shield impacted SNR and performance by
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Center for Magnetic Resonance Research (CMRR), University of Minnesota, Minneapolis, Minnesota, USA.
ORCID-Profile: Tobey D Haluptzok, Russell L Lagore, Simon Schmidt, Gregory J Metzger
Förderung
- NIBIB NIH HHS
- National Institute of Biomedical Imaging and Bioengineering
Zitieren
APA
Haluptzok, T. D., Lagore, R. L., Schmidt, S., & Metzger, G. J. (2025). A shielded 32‐channel body transceiver array with integrated electronics for 7 T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30498
Vancouver
Haluptzok TD, Lagore RL, Schmidt S, Metzger GJ. A shielded 32‐channel body transceiver array with integrated electronics for 7 T. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30498
BibTeX
@article{Haluptzok2025,
author = {Haluptzok, Tobey D and Lagore, Russell L and Schmidt, Simon and Metzger, Gregory J},
title = {A shielded 32‐channel body transceiver array with integrated electronics for 7 T},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30498}
}
EUVIMED