Mechanically Adjustable 4-Channel RF Transceiver Coil Array for Rat Brain Imaging in a Whole-Body 7 T MR Scanner
Sensors · 2024
DOI: 10.3390/s24165377 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Sigrun Roat und 2 weiteren Autor:innen. Beteiligte Einrichtung: High Field MR Center, Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, 1090 Vienna, Austria. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Brain. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: FWF Austrian Science Fund, Alsix GmbH, Austrian Science Fund.
Abstract (Originalsprache)
Investigations of human brain disorders are frequently conducted in rodent models using magnetic resonance imaging. Due to the small specimen size and the increase in signal-to-noise ratio with the static magnetic field strength, dedicated small-bore animal scanners can be used to acquire high-resolution data. Ultra-high-field (≥7 T) whole-body human scanners are increasingly available, and they can also be used for animal investigations. Dedicated sensors, in this case, radiofrequency coils, are required to achieve sufficient sensitivity for the high spatial resolution needed for imaging small anatomical structures. In this work, a four-channel transceiver coil array for rat brain imaging at 7 T is presented, which can be adjusted for use on a wide range of differently sized rats, from infants to large adults. Three suitable array designs (with two to four elements covering the whole rat brain) were compared using full-wave 3D electromagnetic simulation. An optimized static B1+ shim was derived to maximize B1+ in the rat brain for both small and big rats. The design, together with a 3D-printed adjustable coil housing, was tested and validated in ex vivo rat bench and MRI measurements.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- High Field MR Center, Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, 1090 Vienna, Austria.
ORCID-Profile: Sigrun Roat, Lena Nohava, Elmar Laistler
Förderung
- FWF Austrian Science Fund
- Alsix GmbH
- Austrian Science Fund
Zitieren
APA
Roat, S., Nohava, L., & Laistler, E. (2024). Mechanically Adjustable 4-Channel RF Transceiver Coil Array for Rat Brain Imaging in a Whole-Body 7 T MR Scanner. Sensors. https://doi.org/10.3390/s24165377
Vancouver
Roat S, Nohava L, Laistler E. Mechanically Adjustable 4-Channel RF Transceiver Coil Array for Rat Brain Imaging in a Whole-Body 7 T MR Scanner. Sensors. 2024. doi:10.3390/s24165377
BibTeX
@article{Roat2024,
author = {Roat, Sigrun and Nohava, Lena and Laistler, Elmar},
title = {Mechanically Adjustable 4-Channel RF Transceiver Coil Array for Rat Brain Imaging in a Whole-Body 7 T MR Scanner},
journal = {Sensors},
year = {2024},
doi = {10.3390/s24165377}
}
EUVIMED