Flexible, high spatial and temporal resolution absolute thermometry of MRI phantoms using ethylene glycol
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30487 ↗At a glance
Journal article in Magnetic Resonance in Medicine, 2025. Written by Wesley Judd and 4 co-authors. Institution: Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, USA. Major MEDLINE topics: Phantoms, Imaging, Magnetic Resonance Imaging, Ethylene Glycol, Thermometry. 18 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: NIH HHS, NIBIB NIH HHS, RRD VA.
Abstract (original language)
Purpose
Quantitative MRI (qMRI) parameters such as relaxation rates and diffusion parameters are typically temperature dependent. Therefore, using phantoms to evaluate the accuracy of qMRI pulse sequences requires accurate knowledge of the absolute temperature throughout the phantom. This work aims to evaluate the use of ethylene glycol (EG) together with a multi‐echo gradient recalled echo (ME‐GRE) pulse sequence for MR spectroscopic‐based measurement of absolute temperature in phantoms.
Methods
We develop and test a simple MR spectroscopic imaging approach to rapidly, automatically, accurately, and precisely measure absolute temperature at multiple locations throughout a qMRI phantom. A series of EG cubes are located throughout the phantom and imaged with a ME‐GRE pulse sequence over a wide range of temperatures (˜7°C–37°C) and on multiple scanners. The resulting images were automatically processed to isolate the EG. The measured spectral peak spacing was calibrated to temperature using fiber optic probes. The accuracy and precision of the measurements were evaluated between scanners over a range of temperatures.
Results
The spectral peak spacing of EG can be used to predict temperature with an error of 0.6°C ± 0.3°C with an increase of 0.1°C when evaluated on different scanners. An automatic reconstruction approach without manual input is described, highlighting the feasibility of online implementation on a clinical MRI scanner.
Conclusion
The described MR spectroscopic imaging approach is easy to implement and provides robust, automatic, and accurate measurement of absolute temperature throughout a phantom.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, USA.
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, USA.
- Psychology Software Tools, Pittsburgh, PA, USA.
ORCID profiles: Wesley Judd, Seong-Eun Kim, Dennis L Parker, Henrik Odéen
Funding
- NIH HHS
- NIBIB NIH HHS
- RRD VA
- US Department of Veterans Affairs, Veterans Health Administration
- US Department of Veterans Affairs
- National Institutes of Health
- U.S. Department of Veterans Affairs
Cite
APA
Judd, W., Kim, S. E., Dzikiy, J., Parker, D. L., & Odéen, H. (2025). Flexible, high spatial and temporal resolution absolute thermometry of MRI phantoms using ethylene glycol. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30487
Vancouver
Judd W, Kim SE, Dzikiy J, Parker DL, Odéen H. Flexible, high spatial and temporal resolution absolute thermometry of MRI phantoms using ethylene glycol. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30487
BibTeX
@article{Judd2025,
author = {Judd, Wesley and Kim, Seong-Eun and Dzikiy, John and Parker, Dennis L and Odéen, Henrik},
title = {Flexible, high spatial and temporal resolution absolute thermometry of MRI phantoms using ethylene glycol},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30487}
}
EUVIMED