EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Flexible, high spatial and temporal resolution absolute thermometry of MRI phantoms using ethylene glycol

Wesley Judd iD, Seong-Eun Kim iD, John Dzikiy, Dennis L Parker iD, Henrik Odéen iD

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.30487 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Wesley Judd und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, USA. Hauptthemen laut MEDLINE: Phantoms, Imaging, Magnetic Resonance Imaging, Ethylene Glycol, Thermometry. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIH HHS, NIBIB NIH HHS, RRD VA.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Quantitative MRI (qMRI) parameters such as relaxation rates and diffusion parameters are typically temperature dependent. Therefore, using phantoms to evaluate the accuracy of qMRI pulse sequences requires accurate knowledge of the absolute temperature throughout the phantom. This work aims to evaluate the use of ethylene glycol (EG) together with a multi‐echo gradient recalled echo (ME‐GRE) pulse sequence for MR spectroscopic‐based measurement of absolute temperature in phantoms.

Methods

We develop and test a simple MR spectroscopic imaging approach to rapidly, automatically, accurately, and precisely measure absolute temperature at multiple locations throughout a qMRI phantom. A series of EG cubes are located throughout the phantom and imaged with a ME‐GRE pulse sequence over a wide range of temperatures (˜7°C–37°C) and on multiple scanners. The resulting images were automatically processed to isolate the EG. The measured spectral peak spacing was calibrated to temperature using fiber optic probes. The accuracy and precision of the measurements were evaluated between scanners over a range of temperatures.

Results

The spectral peak spacing of EG can be used to predict temperature with an error of 0.6°C ± 0.3°C with an increase of 0.1°C when evaluated on different scanners. An automatic reconstruction approach without manual input is described, highlighting the feasibility of online implementation on a clinical MRI scanner.

Conclusion

The described MR spectroscopic imaging approach is easy to implement and provides robust, automatic, and accurate measurement of absolute temperature throughout a phantom.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Phantoms, ImagingMagnetic Resonance ImagingEthylene GlycolThermometryReproducibility of ResultsAlgorithmsMagnetic Resonance SpectroscopyHumansTemperature

Stichwörter der Autor:innen

MR thermometryabsolute MR thermometryethylene glycolphantomquantitative MRItrue temperature

Substanzen

Ethylene Glycol

Autor:innen und Institutionen

  • Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, USA.
  • Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, USA.
  • Psychology Software Tools, Pittsburgh, PA, USA.

ORCID-Profile: Wesley Judd, Seong-Eun Kim, Dennis L Parker, Henrik Odéen

Förderung

  • NIH HHS
  • NIBIB NIH HHS
  • RRD VA
  • US Department of Veterans Affairs, Veterans Health Administration
  • US Department of Veterans Affairs
  • National Institutes of Health
  • U.S. Department of Veterans Affairs

Zitieren

APA

Judd, W., Kim, S. E., Dzikiy, J., Parker, D. L., & Odéen, H. (2025). Flexible, high spatial and temporal resolution absolute thermometry of MRI phantoms using ethylene glycol. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30487

Vancouver

Judd W, Kim SE, Dzikiy J, Parker DL, Odéen H. Flexible, high spatial and temporal resolution absolute thermometry of MRI phantoms using ethylene glycol. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30487

BibTeX
@article{Judd2025,
  author = {Judd, Wesley and Kim, Seong-Eun and Dzikiy, John and Parker, Dennis L and Odéen, Henrik},
  title = {Flexible, high spatial and temporal resolution absolute thermometry of MRI phantoms using ethylene glycol},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30487}
}
Kostenlos starten →