Journal article in Magnetic Resonance in Medicine, 2025. Written by Philip K Lee and 2 co-authors. Institution: Radiology, Stanford University, Stanford, California, USA. Major MEDLINE topics: Diffusion Magnetic Resonance Imaging, Artifacts, Brain, Image Processing, Computer-Assisted. 44 references. The full text is freely available in PubMed Central. Funded by: NCI NIH HHS, GE Healthcare, NIH HHS.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Purpose

Diffusion‐prepared imaging is a flexible alternative to conventional spin‐echo diffusion‐weighted EPI that allows selection of different imaging readouts and k‐space traversals, and permits control of image contrast or image artifacts. We investigate a new signal model and reconstruction for diffusion‐prepared imaging that addresses signal variations caused by motion‐sensitizing diffusion gradients.

Methods

A signal model, sampling theory, and reconstruction framework were developed assuming that motion‐induced phases and the measured signals are random variables. The reconstruction incorporates real‐valued amplitude weights estimated from low‐resolution images into a linear system. A diffusion‐prepared sequence was applied in phantom and in vivo acquisitions using different methods for managing phase errors from eddy currents or motion. This acquisition was performed with a high number of NEX and retrospectively undersampled to analyze errors in ADC estimation, and compared to spin‐echo diffusion‐weighted EPI, as well as conventional diffusion‐prepared methods. The B 1 sensitivity of the sequence was investigated using simulation and phantom experiments.

Results

Images reconstructed using the proposed method had similar image structures when compared to conventional spin‐echo diffusion‐weighted EPI, and demonstrated improved SNR efficiency compared to previous diffusion‐prepared approaches. ADC errors followed a trend consistent with the derived signal model, sampling theory, and expected B 1 sensitivity. The sampling requirement was shown to depend on the magnitude of motion‐induced phases, as well as phases from residual eddy currents.

Conclusion

Employing amplitude weights in the reconstruction of a diffusion‐prepared sequence can improve SNR efficiency at the cost of a greater minimum sampling time and increased sensitivity to B 1 inhomogeneity.

Subjects

MeSH terms (MEDLINE)

Diffusion Magnetic Resonance ImagingArtifactsBrainImage Processing, Computer-AssistedImage EnhancementPhantoms, ImagingHumansMotionAlgorithmsReproducibility of ResultsComputer SimulationSignal Processing, Computer-AssistedSensitivity and SpecificitySignal-To-Noise Ratio

Author keywords

diffusion MRIimage reconstructionlinear systems

Authors and institutions

  • Radiology, Stanford University, Stanford, California, USA.
  • Bioengineering, Stanford University, Stanford, California, USA.
  • Electrical Engineering, Stanford University, Stanford, California, USA.

ORCID profiles: Philip K Lee, Xuetong Zhou

Funding

  • NCI NIH HHS
  • GE Healthcare
  • NIH HHS
  • National Institutes of Health

Cite

APA

Lee, P. K., Zhou, X., & Hargreaves, B. A. (2025). Diffusion‐prepared imaging with amplitude navigation for correction of motion‐induced signal loss. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30484

Vancouver

Lee PK, Zhou X, Hargreaves BA. Diffusion‐prepared imaging with amplitude navigation for correction of motion‐induced signal loss. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30484

BibTeX
@article{Lee2025,
  author = {Lee, Philip K and Zhou, Xuetong and Hargreaves, Brian A},
  title = {Diffusion‐prepared imaging with amplitude navigation for correction of motion‐induced signal loss},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30484}
}
Start for free →