Real‐Time Targeted Slice Reacquisition for Motion‐Corrupted Fetal Diffusion MRI
Magnetic Resonance in Medicine · 2026
DOI: 10.1002/mrm.70484 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Jordina Aviles Verdera und 7 weiteren Autor:innen. Beteiligte Einrichtung: Imaging Physics and Engineering Research Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK. Hauptthemen laut MEDLINE: Diffusion Magnetic Resonance Imaging, Image Processing, Computer-Assisted, Fetus, Prenatal Diagnosis. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft, Lower Saxony Ministry of Science and Culture, European Research Council.
Abstract (Originalsprache)
Purpose
To develop and evaluate a real‐time framework for targeted slice‐level reacquisition in fetal diffusion MRI.
Methods
A DW‐SE‐EPI sequence was modified to support independent diffusion preparation per slice. A pathology‐robust nnU‐Net segmentation network, updated from a previously published baseline (V1) using pathological fetal cases and physics‐inspired augmentation (V2), and intensity‐based artifact detection drive automated reacquisition prioritization. Retrospective validation was performed on 60 cases across three cohorts at two field strengths and prospective deployment in 14 cases at two clinical sites.
Results
Segmentation V2 significantly outperformed V1 across all cohorts (), with largest gains at b0 s mm (median DSC gain 0.87 at 1.5 T). Blackout detection achieved F1 = 0.81 0.29 at T = 0.35. Prospective real‐time deployment confirmed clinical feasibility at both field strengths.
Conclusion
Real‐time slice‐level fetal diffusion reacquisition is demonstrated for the first time, opening a pathway toward routine quantitative fetal diffusion MRI in research and clinical settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Imaging Physics and Engineering Research Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
- Institute for Information Processing, Leibniz University Hannover, Hannover, Germany.
- CAIMed, L3S Research Center, Hannover, Germany.
- Radiology Institute, Uniklinikum Erlangen, Erlangen, Germany.
- Early Life Imaging Department, School of Biomedical Engineering and Imaging Sciences, King's college, London, UK.
- MR Research Collaborations, Siemens Healthcare Limited, Camberley, UK.
ORCID-Profile: Jordina Aviles Verdera, Sara Neves Silva, Mary Rutherford, Joseph V Hajnal, Jana Hutter
Förderung
- Deutsche Forschungsgemeinschaft
- Lower Saxony Ministry of Science and Culture
- European Research Council
- Medical Research Council
Zitieren
APA
Aviles Verdera, J., Neves Silva, S., Schulz-Heise, S., McElroy, S., Rutherford, M., Hajnal, J. V., Tomi-Tricot, R., & Hutter, J. (2026). Real‐Time Targeted Slice Reacquisition for Motion‐Corrupted Fetal Diffusion MRI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70484
Vancouver
Aviles Verdera J, Neves Silva S, Schulz-Heise S, McElroy S, Rutherford M, Hajnal JV, et al. Real‐Time Targeted Slice Reacquisition for Motion‐Corrupted Fetal Diffusion MRI. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70484
BibTeX
@article{AvilesVerdera2026,
author = {Aviles Verdera, Jordina and Neves Silva, Sara and Schulz-Heise, Susanne and McElroy, Sarah and Rutherford, Mary and Hajnal, Joseph V and Tomi-Tricot, Raphael and Hutter, Jana},
title = {Real‐Time Targeted Slice Reacquisition for Motion‐Corrupted Fetal Diffusion MRI},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70484}
}
EUVIMED