3D deuterium metabolic imaging ( DMI ) of the human liver at 7 T using low‐rank and subspace model‐based reconstruction

Kyung Min Nam iD, Ayhan Gursan, Nam G Lee iD, Dennis W J Klomp, Jannie P Wijnen, Jeanine J Prompers iD, Arjan D Hendriks iD, Alex A Bhogal

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.30395 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Kyung Min Nam und 7 weiteren Autor:innen. Beteiligte Einrichtung: Center for Image Sciences, High Field MR Research Group, Department of Radiology, University Medical Centre Utrecht, Utrecht, The Netherlands. Hauptthemen laut MEDLINE: Liver, Deuterium, Imaging, Three-Dimensional, Magnetic Resonance Imaging. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 71 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Union's Horizon 2020 research and innovation program under the Marie Sklodowska-Curie grant agreement, The information Technology for European Advancement program (ITEA4), MITI (EU EIC Transition) Non-ionizing Metabolic Imaging for predicting the effect of and guiding Therapeutic Interventions.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To implement a low‐rank and subspace model‐based reconstruction for 3D deuterium metabolic imaging (DMI) and compare its performance against Fourier transform‐based (FFT) reconstruction in terms of spectral fitting reliability.

Methods

Both reconstruction methods were applied on simulated and experimental DMI data. Numerical simulations were performed to evaluate the effect of increasing acceleration factors. The impact on spectral fitting results, SNR, and the overall normalized root mean square error (NRMSE) compared to ground‐truth data were calculated. A comparative analysis was performed on DMI data acquired from the human liver, including both natural abundance and post‐deuterated glucose intake data at 7 T.

Results

Simulation showed the Cramer‐Rao lower bound [%] of water, glucose, sum of glutamate and glutamine (Glx), and lipid signals for the low‐rank and subspace model‐based reconstruction at R = 1.0 was 12.4, 14.7, 17.3, and 11.0 times lower than FFT. At R = 1.1, NRMSE was 1.4%, 1.3%, 0.8%, and 4.2% lower for the water, glucose, Glx, and lipid, respectively, compared to FFT. However, the NRMSE of the Glx and lipid increased by 0.4% and 3.2% at R = 1.3. For the in vivo DMI experiment, SNR was 2.5–3.0 times higher compared to FFT. The fitted amplitude of water and glucose peaks showed Cramer‐Rao lower bound [%] values that were approximately 2.3 times lower than FFT.

Conclusion

Simulations and in vivo experiments on the human liver demonstrate that low‐rank and subspace model‐based reconstruction with undersampled data mitigates noise and enhances spectral fitting quality.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LiverDeuteriumImaging, Three-DimensionalMagnetic Resonance ImagingImage Processing, Computer-AssistedHumansComputer SimulationAlgorithmsReproducibility of ResultsSignal-To-Noise RatioFourier AnalysisGlucoseMalePhantoms, Imaging

Stichwörter der Autor:innen

2H7 TDMISPICEdeuteriumdeuterium MRSIliverlow ranksubspace model

Substanzen

DeuteriumGlucose

Autor:innen und Institutionen

  • Center for Image Sciences, High Field MR Research Group, Department of Radiology, University Medical Centre Utrecht, Utrecht, The Netherlands.
  • Alfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, California, USA.

ORCID-Profile: Kyung Min Nam, Nam G Lee, Jeanine J Prompers, Arjan D Hendriks

Förderung

  • European Union's Horizon 2020 research and innovation program under the Marie Sklodowska-Curie grant agreement
  • The information Technology for European Advancement program (ITEA4)
  • MITI (EU EIC Transition) Non-ionizing Metabolic Imaging for predicting the effect of and guiding Therapeutic Interventions

Zitieren

APA

Nam, K. M., Gursan, A., Lee, N. G., Klomp, D. W. J., Wijnen, J. P., Prompers, J. J., Hendriks, A. D., & Bhogal, A. A. (2025). 3D deuterium metabolic imaging ( DMI ) of the human liver at 7 T using low‐rank and subspace model‐based reconstruction. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30395

Vancouver

Nam KM, Gursan A, Lee NG, Klomp DWJ, Wijnen JP, Prompers JJ, et al. 3D deuterium metabolic imaging ( DMI ) of the human liver at 7 T using low‐rank and subspace model‐based reconstruction. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30395

BibTeX
@article{Nam2025,
  author = {Nam, Kyung Min and Gursan, Ayhan and Lee, Nam G and Klomp, Dennis W J and Wijnen, Jannie P and Prompers, Jeanine J and Hendriks, Arjan D and Bhogal, Alex A},
  title = {3D deuterium metabolic imaging ( DMI ) of the human liver at 7 T using low‐rank and subspace model‐based reconstruction},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30395}
}
Kostenlos starten →