EUVIMEDEUVIMED entdecken
Open Access

Quiescent frame, contrast-enhanced coronary magnetic resonance angiography reconstructed using limited number of physiologic frames from 5D free-running acquisitions

Yitong Yang, Jackson Hair, Jérôme Yerly, Davide Piccini, Lorenzo Di Sopra, Aurelien Bustin, Milan Prsa, Salim Si-Mohamed, Matthias Stuber, John N Oshinski

Magnetic Resonance Imaging · 2024

DOI: 10.1016/j.mri.2024.07.008 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2024. Verfasst von Yitong Yang und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, United States. Hauptthemen laut MEDLINE: Contrast Media, Magnetic Resonance Angiography, Imaging, Three-Dimensional. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, NINDS NIH HHS, NHLBI NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: 5D, free-running imaging resolves sets of 3D whole-heart images in both cardiac and respiratory dimensions. In an application such as coronary imaging when a single, static image is of interest, computationally expensive offline iterative reconstruction is still needed to compute the multiple 3D datasets. PURPOSE: Evaluate how the number of physiologic bins included in the reconstruction affects the computational cost and resulting image quality of a single, static volume reconstruction. STUDY TYPE: Retrospective. SUBJECTS: 15 pediatric patients following Ferumoxytol infusion (4 mg/kg). FIELD STRENGTH/SEQUENCE: 1.5 T/Ungated 5D free-running GRE sequence. ASSESSMENT: The raw data of each subject were binned and reconstructed into a 5D (x-y-z-cardiac-respiratory) images. 1, 3, 5, 7, and 9 bins adjacent to both sides of the retrospectively determined cardiac resting phase and 1, 3 bins adjacent to the end-expiration phase are used for limited frame reconstructions. The static volume within each limited reconstruction was compared with the corresponding full 5D reconstruction using the structural similarity index measure (SSIM). A non-linear regression model was used to fit SSIM with the percentage of data used compared to full reconstruction (% data). A linear regression model was used to fit computation time with % raw data used. Coronary artery sharpness is measured on each limited reconstructed images to determine the minimal number of cardiac and respiratory bins needed to preserve image quality. STATISTICAL TESTS: The coefficient of determination (R2) is computed for each regression model. RESULTS: The % of data used in the reconstruction was linearly related to the computational time (R2 = 0.99). The SSIM of the static image from the limited reconstructions is non-linearly related with the % of data used (R2 = 0.80). Over the 15 patients, the model showed SSIM of 0.9 with 18% of data, and SSIM of 0.96 with 30% of data. The coronary artery sharpness of images reconstructed using no less than 5 cardiac and all respiratory phases is not significantly different from the full reconstructed images using all cardiac and respiratory bins. DATA CONCLUSION: Reconstruction using only a limited number of acquired physiological states can linearly reduce the computational cost while preserving similarity to the full reconstruction image. It is suggested to use no less than 5 cardiac and all respiratory phases in the limited reconstruction to best preserve the original quality seen on the full reconstructed images.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Contrast MediaMagnetic Resonance AngiographyImaging, Three-DimensionalHumansRetrospective StudiesMaleFemaleChildAdolescentImage Processing, Computer-AssistedAlgorithmsHeartFerrosoferric OxideCoronary VesselsImage Interpretation, Computer-AssistedChild, Preschool

Stichwörter der Autor:innen

5D whole-heart MRICoronary MRAFree-running

Substanzen

Contrast MediaFerrosoferric Oxide

Autor:innen und Institutionen

  • Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, United States.
  • Department of Diagnostic and Interventional Radiology, Lausanne University Hospital, Lausanne, Switzerland; Center for Biomedical Imaging, Lausanne, Switzerland.
  • Department of Diagnostic and Interventional Radiology, Lausanne University Hospital, Lausanne, Switzerland; Advanced Clinical Imaging Technology, Siemens Healthcare, Lausanne, Switzerland.
  • Department of Interventional Cardiology, Lausanne University Hospital, Lausanne, Switzerland.
  • Department of Radiology, University of Claude Bernard Lyon 1., Lyon, France.
  • Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, United States; Department of Radiology, Emory University School of Medicine, Atlanta, GA, United States. Electroni…

Förderung

  • NIBIB NIH HHS
  • NINDS NIH HHS
  • NHLBI NIH HHS
  • National Institutes of Health

Zitieren

APA

Yang, Y., Hair, J., Yerly, J., Piccini, D., Di Sopra, L., Bustin, A., Prsa, M., Si-Mohamed, S., Stuber, M., & Oshinski, J. N. (2024). Quiescent frame, contrast-enhanced coronary magnetic resonance angiography reconstructed using limited number of physiologic frames from 5D free-running acquisitions. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2024.07.008

Vancouver

Yang Y, Hair J, Yerly J, Piccini D, Di Sopra L, Bustin A, et al. Quiescent frame, contrast-enhanced coronary magnetic resonance angiography reconstructed using limited number of physiologic frames from 5D free-running acquisitions. Magnetic Resonance Imaging. 2024. doi:10.1016/j.mri.2024.07.008

BibTeX
@article{Yang2024,
  author = {Yang, Yitong and Hair, Jackson and Yerly, Jérôme and Piccini, Davide and Di Sopra, Lorenzo and Bustin, Aurelien and Prsa, Milan and Si-Mohamed, Salim and Stuber, Matthias and Oshinski, John N},
  title = {Quiescent frame, contrast-enhanced coronary magnetic resonance angiography reconstructed using limited number of physiologic frames from 5D free-running acquisitions},
  journal = {Magnetic Resonance Imaging},
  year = {2024},
  doi = {10.1016/j.mri.2024.07.008}
}
Kostenlos starten →