Hyperpolarized Water for Coronary Artery Angiography and Whole-Heart Myocardial Perfusion Quantification
Tomography · 2024
DOI: 10.3390/tomography10070084 ↗Kurz gefasst
Fachartikel in der Zeitschrift Tomography, 2024. Verfasst von Yupeng Zhao und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Health Technology, Technical University of Denmark, DK-2800 Kgs. Lyngby, Denmark. Hauptthemen laut MEDLINE: Coronary Angiography, Water, Coronary Vessels. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Union's Horizon 2020, European Union’s Horizon 2020.
Abstract (Originalsprache)
Purpose
Water freely diffuses across cell membranes, making it suitable for measuring absolute tissue perfusion. In this study, we introduce an imaging method for conducting coronary artery angiography and quantifying myocardial perfusion across the entire heart using hyperpolarized water.
Methods
1H was hyperpolarized using dissolution dynamic nuclear polarization (dDNP) with UV-generated radicals. Submillimeter resolution coronary artery images were acquired as 2D projections using a spoiled GRE (SPGRE) sequence gated on diastole. Dynamic perfusion images were obtained with a multi-slice SPGRE with diastole gating, covering the entire heart. Perfusion values were analyzed through histograms, and the most frequent estimated perfusion value (the mode of the distribution), was compared with the average values for 15O water PET from the literature.
Results
A liquid state polarization of 10% at the time of the injection and a 30 s T1 in D2O TRIS buffer were measured. Both coronary artery and dynamic perfusion images exhibited good quality. The main and small coronary artery branches were well resolved. The most frequent estimated perfusion value is around 0.6 mL/g/min, which is lower than the average values obtained from the literature for 15O-water PET (around 1.1 and 1.5 mL/g/min).
Conclusions
The study successfully demonstrated the feasibility of achieving high-resolution, motion-free coronary artery angiography and 3D whole-heart quantitative myocardial perfusion using hyperpolarized water.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Health Technology, Technical University of Denmark, DK-2800 Kgs. Lyngby, Denmark.
- MR Research Centre, Aarhus University, DK-8200 Aarhus, Denmark.
- Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Hvidovre, DK-2650 Hvidovre, Denmark.
ORCID-Profile: Yupeng Zhao, Mathilde Hauge Lerche, Magnus Karlsson, Rie Beck Olin, Esben Søvsø Szocska Hansen, Malene Aastrup, Mohsen Redda, Christoffer Laustsen, Lars G Hanson, Jan Henrik Ardenkjær-Larsen
Förderung
- European Union's Horizon 2020
- European Union’s Horizon 2020
Zitieren
APA
Zhao, Y., Lerche, M. H., Karlsson, M., Olin, R. B., Hansen, E. S. S., Aastrup, M., Redda, M., Laustsen, C., Hanson, L. G., & Ardenkjær-Larsen, J. H. (2024). Hyperpolarized Water for Coronary Artery Angiography and Whole-Heart Myocardial Perfusion Quantification. Tomography. https://doi.org/10.3390/tomography10070084
Vancouver
Zhao Y, Lerche MH, Karlsson M, Olin RB, Hansen ESS, Aastrup M, et al. Hyperpolarized Water for Coronary Artery Angiography and Whole-Heart Myocardial Perfusion Quantification. Tomography. 2024. doi:10.3390/tomography10070084
BibTeX
@article{Zhao2024,
author = {Zhao, Yupeng and Lerche, Mathilde Hauge and Karlsson, Magnus and Olin, Rie Beck and Hansen, Esben Søvsø Szocska and Aastrup, Malene and Redda, Mohsen and Laustsen, Christoffer and Hanson, Lars G and Ardenkjær-Larsen, Jan Henrik},
title = {Hyperpolarized Water for Coronary Artery Angiography and Whole-Heart Myocardial Perfusion Quantification},
journal = {Tomography},
year = {2024},
doi = {10.3390/tomography10070084}
}