Rapid whole‐brain T 2 * and susceptibility mapping using 3D multiple overlapping‐echo detachment acquisition and missing modality synthesis embedded simulation

Qinqin Yang iD, Longkun Chen, Nuowei Ge, Jie Chen, Jingying Yang, Zejun Wu, Chenyang Dai, Shuhui Cai iD, Zhong Chen, Lijun Bao, Liuhong Zhu, Jianfeng Bao und 1 weitere

Magnetic Resonance in Medicine · 2026

DOI: 10.1002/mrm.70108 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Qinqin Yang und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electronic Science, Xiamen University, Xiamen, China. Hauptthemen laut MEDLINE: Brain, Imaging, Three-Dimensional, Magnetic Resonance Imaging, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 57 Literaturangaben. Gefördert von: National Key R&D Program of China, Science and Technology Project of Fujian Province of China, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To develop a 3D multiple overlapping‐echo detachment (3D‐MOLED) imaging technique, along with data generation and reconstruction strategies, for rapid whole‐brain T 2 * and QSM.

Methods

MOLED encoding was extended to a 3D multi‐shot acquisition and combined with dual‐echo blip‐reversed EPI trains to simultaneously acquire T 2 * and QSM signals while reducing image distortion. To enable Bloch simulation for training data generation, a deep learning‐based missing modality synthesis approach was employed to produce co‐registered multi‐parametric templates. In addition, a pseudo‐3D Bloch simulation was proposed to accelerate synthetic data generation for network training. A cohort of healthy volunteers and clinical participants were recruited to evaluate the motion robustness of the proposed method in comparison with conventional 3D‐GRE.

Results

Compared to 3D‐GRE, 3D‐MOLED achieved significant improvements in both scan speed and motion robustness, with over 70% of scans rated as good image quality in both healthy and clinical cohorts. The missing modality synthesis approach generated high‐quality 3D multi‐parametric maps. Combined with the pseudo‐3D Bloch simulation framework, it enabled efficient generation of paired training data with acceptable computational cost, thereby facilitating accurate quantitative mapping.

Conclusion

3D‐MOLED enables simultaneous whole‐brain T 2 * and QSM mapping at 1 mm isotropic resolution in 50 s, offering superior motion robustness compared to conventional 3D‐GRE.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BrainImaging, Three-DimensionalMagnetic Resonance ImagingImage Processing, Computer-AssistedEcho-Planar ImagingBrain MappingHumansAdultMaleAlgorithmsFemaleDeep LearningComputer SimulationHealthy Volunteers

Stichwörter der Autor:innen

3D imagingMOLEDQSMT2* mappingmodality synthesis

Autor:innen und Institutionen

  • Department of Electronic Science, Xiamen University, Xiamen, China.
  • Department of Radiological Sciences, University of California Irvine, Irvine, California, USA.
  • Department of Radiology, Zhongshan Hospital (Xiamen), Fudan University, Xiamen, China.
  • Department of Magnetic Resonance Imaging, The First Affiliated Hospital of Zhengzhou University, Zhengzhou University, Zhengzhou, China.

ORCID-Profile: Qinqin Yang, Shuhui Cai

Förderung

  • National Key R&D Program of China
  • Science and Technology Project of Fujian Province of China
  • National Natural Science Foundation of China
  • National Key Research and Development Program of China

Zitieren

APA

Yang, Q., Chen, L., Ge, N., Chen, J., Yang, J., Wu, Z., Dai, C., Cai, S., Chen, Z., Bao, L., Zhu, L., Bao, J., & Cai, C. (2026). Rapid whole‐brain T 2 * and susceptibility mapping using 3D multiple overlapping‐echo detachment acquisition and missing modality synthesis embedded simulation. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70108

Vancouver

Yang Q, Chen L, Ge N, Chen J, Yang J, Wu Z, et al. Rapid whole‐brain T 2 * and susceptibility mapping using 3D multiple overlapping‐echo detachment acquisition and missing modality synthesis embedded simulation. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70108

BibTeX
@article{Yang2026,
  author = {Yang, Qinqin and Chen, Longkun and Ge, Nuowei and Chen, Jie and Yang, Jingying and Wu, Zejun and Dai, Chenyang and Cai, Shuhui and Chen, Zhong and Bao, Lijun and Zhu, Liuhong and Bao, Jianfeng and Cai, Congbo},
  title = {Rapid whole‐brain T 2 * and susceptibility mapping using 3D multiple overlapping‐echo detachment acquisition and missing modality synthesis embedded simulation},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70108}
}
Kostenlos starten →