EUVIMEDObjevte EUVIMED
Open access

Spectrally selective and interleaved water imaging and fat imaging ( siWIFI )

Soo Hyun Shin iD, Qingbo Tang, Michael Carl, Jiyo S Athertya iD, Arya Suprana, Yajun Ma

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.30366 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, 2025. Written by Soo Hyun Shin and 5 co-authors. Institution: Department of Radiology, University of California, San Diego, La Jolla, California, USA. Major MEDLINE topics: Adipose Tissue, Magnetic Resonance Imaging, Image Processing, Computer-Assisted, Body Water. 40 references. The full text is freely available in PubMed Central. Funded by: NIAMS NIH HHS, NIH HHS, National Institutes of Health.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Purpose

To develop a novel imaging sequence that independently acquires water and fat images while being inherently insensitive to motion.

Methods

The new sequence, termed spectrally selective and interleaved water imaging and fat imaging (siWIFI), uses a narrow bandwidth RF pulse for selective excitation of water and fat separately. The interleaved acquisition method ensures that the obtained water and fat images are inherently coregistered. A radial sampling strategy further reduces motion‐induced artifacts. Phantoms with lipid concentrations ranging from 0% to 50% were scanned to measure fat fraction. Moreover, healthy volunteers were scanned to assess the in vivo feasibility of fat fraction measurement at the hip, knee, and liver. In vivo fat fraction measurements were compared with those from vendor‐provided iterative decomposition of water and fat with echo asymmetry and least‐squares estimation (IDEAL) scans. Furthermore, a magnetization transfer (MT) preparation module was incorporated to demonstrate the feasibility of simultaneous measurement of fat fraction and MT ratio utilizing the siWIFI framework.

Results

The phantom fat fractions measured by siWIFI showed excellent correlation with lipid concentrations ( R 2 = 0.9995, p < 0.0001). In vivo studies demonstrated that the fat fractions obtained from siWIFI were comparable to those from IDEAL. Additionally, siWIFI demonstrates reduced motion artifacts from pulsatile flow in knee imaging compared to IDEAL scans and exhibits less sensitivity to respiratory motion in liver imaging compared to IDEAL scans without breath‐hold. The knee imaging study demonstrated that MT‐prepared siWIFI is capable of generating fat fraction and MT ratio maps simultaneously.

Conclusion

The proposed siWIFI sequence allows selective water–fat imaging and quantification with reduced motion artifacts.

Subjects

MeSH terms (MEDLINE)

Adipose TissueMagnetic Resonance ImagingImage Processing, Computer-AssistedBody WaterHumansPhantoms, ImagingLiverAdultArtifactsMaleAlgorithmsKneeFemaleWaterHealthy VolunteersHip

Author keywords

fat imaginginterleaved acquisitionwater imaging

Substances

Water

Authors and institutions

  • Department of Radiology, University of California, San Diego, La Jolla, California, USA.
  • Research Service, VA San Diego Healthcare System, La Jolla, California, USA.
  • GE Healthcare, San Diego, California, USA.
  • Shu Chein-Gene Lay Department of Bioengineering, University of California, San Diego, La Jolla, California, USA.

ORCID profiles: Soo Hyun Shin, Jiyo S Athertya

Funding

  • NIAMS NIH HHS
  • NIH HHS
  • National Institutes of Health

Cite

APA

Shin, S. H., Tang, Q., Carl, M., Athertya, J. S., Suprana, A., & Ma, Y. (2025). Spectrally selective and interleaved water imaging and fat imaging ( siWIFI ). Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30366

Vancouver

Shin SH, Tang Q, Carl M, Athertya JS, Suprana A, Ma Y. Spectrally selective and interleaved water imaging and fat imaging ( siWIFI ). Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30366

BibTeX
@article{Shin2025,
  author = {Shin, Soo Hyun and Tang, Qingbo and Carl, Michael and Athertya, Jiyo S and Suprana, Arya and Ma, Yajun},
  title = {Spectrally selective and interleaved water imaging and fat imaging ( siWIFI )},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30366}
}
Start for free →