Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Jiayi Tang und 12 weiteren Autor:innen. Beteiligte Einrichtung: Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA. Hauptthemen laut MEDLINE: Liver, Adipose Tissue, Magnetic Resonance Imaging. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS, National Institute of Biomedical Imaging and Bioengineering.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To implement, optimize, and validate parallel imaging (PI)‐accelerated, 2D, flip angle modulated (FAM) chemical shift‐encoded quantification of liver proton‐density fat fraction (PDFF), with motion insensitivity.

Methods

The optimization cost function that determines flip angles in FAM was generalized for PI. Phantom studies and prospective studies in volunteers with varying liver fat levels were performed. Free‐breathing FAM was acquired in the axial, sagittal, and coronal planes, with varying nominal PI acceleration factors ( R ) of 1.0 to 3.0. A breath‐held, commercially available 3D chemical shift‐encoded method was acquired as reference for PDFF. Overall image quality, qualitative SNR, and motion artifacts for all methods were Likert‐scale rated. PDFF measured by FAM was compared to reference to assess bias. Test–retest repeatability was assessed for all methods by repeating acquisitions after volunteer repositioning. Noise performance was assessed with standard deviation of PDFF maps as R increased.

Results

The reader study ( N = 3 readers/10 subjects) demonstrated excellent image quality for FAM during free‐breathing, with reduced motion artifacts compared to breath‐held reference ( p < 0.01). PI‐accelerated FAM shows fewer motion artifacts than unaccelerated FAM ( p < 0.01). In all planes and accelerations, PDFF measured by FAM showed good agreement with reference PDFF measurements (mean bias: −0.4% to 2.0% PDFF; 95% limits of agreement: 2.8% to 4.0% PDFF). FAM in axial and coronal planes showed similar or improved repeatability (repeatability coefficient = 1.7% to 2.6% PDFF) compared to the reference (2.7%). Sagittal FAM shows similar or worse repeatability (repeatability coefficient = 3.0% to 3.6%). FAM with R = 2.0 has good noise performance and high SNR efficiency.

Conclusion

FAM, in axial or coronal planes with R = 2.0, is optimal for motion‐insensitive liver PDFF quantification.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LiverAdipose TissueMagnetic Resonance ImagingHumansProtonsPhantoms, ImagingArtifactsNon-alcoholic Fatty Liver DiseaseBody Mass IndexMaleFemaleAdultMiddle AgedReproducibility of ResultsImaging, Three-Dimensional

Stichwörter der Autor:innen

MASLDPDFFfat quantificationlivermotion robustnessproton density fat fraction

Substanzen

Protons

Autor:innen und Institutionen

  • Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA.
  • Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA.
  • Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany.
  • Department of Diagnostic and Interventional Radiology, University Medical Center Mainz, Mainz, Germany.
  • Calimetrix, LLC, Madison, Wisconsin, USA.
  • Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA.

ORCID-Profile: Jiayi Tang, Daiki Tamada, Raphael do Vale Souza, Jitka Starekova, Julius F Heidenreich, Garrett C Fullerton, Collin J Buelo, Scott B Reeder, Diego Hernando

Förderung

  • NIBIB NIH HHS
  • National Institute of Biomedical Imaging and Bioengineering

Zitieren

APA

Tang, J., Tamada, D., do Vale Souza, R., Faacks, A., Starekova, J., Heidenreich, J. F., Müller, L., Fullerton, G. C., Buelo, C. J., Kammerman, J., Brittain, J. H., Reeder, S. B., & Hernando, D. (2026). Optimized motion‐insensitive PDFF mapping of the liver. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70047

Vancouver

Tang J, Tamada D, do Vale Souza R, Faacks A, Starekova J, Heidenreich JF, et al. Optimized motion‐insensitive PDFF mapping of the liver. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70047

BibTeX
@article{Tang2026,
  author = {Tang, Jiayi and Tamada, Daiki and do Vale Souza, Raphael and Faacks, Aaron and Starekova, Jitka and Heidenreich, Julius F and Müller, Lukas and Fullerton, Garrett C and Buelo, Collin J and Kammerman, Jeff and Brittain, Jean H and Reeder, Scott B and Hernando, Diego},
  title = {Optimized motion‐insensitive PDFF mapping of the liver},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70047}
}
Kostenlos starten →