Two‐parametric prescan calibration of gradient‐induced sampling errors for rosette MRI

Peter Latta iD, Radovan Jiřík iD, Jiří Vitouš iD, Ondřej Macíček iD, Lubomír Vojtíšek, Ivan Rektor, Michal Standara, Jan Křístek, Zenon Starčuk iD

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.30355 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, 2025. Written by Peter Latta and 8 co-authors. Institution: Central European Institute of Technology, Masaryk University, Brno, Czech Republic. Major MEDLINE topics: Magnetic Resonance Imaging, Phantoms, Imaging, Algorithms, Image Processing, Computer-Assisted. Cited 1 times so far (Crossref); 34 references. The full text is freely available (open access, CC BY 4.0). Funded by: Ministry of Health of the Czech Republic, Ministry of Health of the Czech Republic - conceptual development of research organization, Czech Science Foundation.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Purpose

The aim of this study was to develop a simple, robust, and easy‐to‐use calibration procedure for correcting misalignments in rosette MRI k‐space sampling, with the objective of producing images with minimal artifacts.

Methods

Quick automatic calibration scans were proposed for the beginning of the measurement to collect information on the time course of the rosette acquisition trajectory. A two‐parameter model was devised to match the measured time‐varying readout gradient delays and approximate the actual rosette sampling trajectory. The proposed calibration approach was implemented, and performance assessment was conducted on both phantoms and human subjects.

Results

The fidelity of phantom and in vivo images exhibited significant improvement compared with uncorrected rosette data. The two‐parameter calibration approach also demonstrated enhanced precision and reliability, as evidenced by quantitative relaxometry analyses.

Conclusion

Adequate correction of data sampling is a crucial step in rosette MRI. The presented experimental results underscore the robustness, ease of implementation, and suitability for routine experimental use of the proposed two‐parameter rosette trajectory calibration approach.

Subjects

MeSH terms (MEDLINE)

Magnetic Resonance ImagingPhantoms, ImagingAlgorithmsImage Processing, Computer-AssistedArtifactsHumansCalibrationReproducibility of ResultsBrain

Author keywords

gradient imperfectionsk‐space misalignmentrosette trajectorytrajectory estimation

Authors and institutions

  • Central European Institute of Technology, Masaryk University, Brno, Czech Republic.
  • Institute of Scientific Instruments of the Czech Academy of Sciences, Brno, Czech Republic.
  • Department of Radiology, Masaryk Memorial Cancer Institute, Brno, Czech Republic.

ORCID profiles: Peter Latta, Radovan Jiřík, Jiří Vitouš, Ondřej Macíček, Zenon Starčuk

Funding

  • Ministry of Health of the Czech Republic
  • Ministry of Health of the Czech Republic - conceptual development of research organization
  • Czech Science Foundation
  • Ministry of Education, Youth and Sports
  • Ministerstvo Zdravotnictví Ceské Republiky
  • Grantová Agentura České Republiky

Cite

APA

Latta, P., Jiřík, R., Vitouš, J., Macíček, O., Vojtíšek, L., Rektor, I., Standara, M., Křístek, J., & Starčuk, Z. (2025). Two‐parametric prescan calibration of gradient‐induced sampling errors for rosette MRI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30355

Vancouver

Latta P, Jiřík R, Vitouš J, Macíček O, Vojtíšek L, Rektor I, et al. Two‐parametric prescan calibration of gradient‐induced sampling errors for rosette MRI. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30355

BibTeX
@article{Latta2025,
  author = {Latta, Peter and Jiřík, Radovan and Vitouš, Jiří and Macíček, Ondřej and Vojtíšek, Lubomír and Rektor, Ivan and Standara, Michal and Křístek, Jan and Starčuk, Zenon},
  title = {Two‐parametric prescan calibration of gradient‐induced sampling errors for rosette MRI},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30355}
}
Start for free →