Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Peter Latta und 8 weiteren Autor:innen. Beteiligte Einrichtung: Central European Institute of Technology, Masaryk University, Brno, Czech Republic. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Phantoms, Imaging, Algorithms, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Health of the Czech Republic, Ministry of Health of the Czech Republic - conceptual development of research organization, Czech Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The aim of this study was to develop a simple, robust, and easy‐to‐use calibration procedure for correcting misalignments in rosette MRI k‐space sampling, with the objective of producing images with minimal artifacts.

Methods

Quick automatic calibration scans were proposed for the beginning of the measurement to collect information on the time course of the rosette acquisition trajectory. A two‐parameter model was devised to match the measured time‐varying readout gradient delays and approximate the actual rosette sampling trajectory. The proposed calibration approach was implemented, and performance assessment was conducted on both phantoms and human subjects.

Results

The fidelity of phantom and in vivo images exhibited significant improvement compared with uncorrected rosette data. The two‐parameter calibration approach also demonstrated enhanced precision and reliability, as evidenced by quantitative relaxometry analyses.

Conclusion

Adequate correction of data sampling is a crucial step in rosette MRI. The presented experimental results underscore the robustness, ease of implementation, and suitability for routine experimental use of the proposed two‐parameter rosette trajectory calibration approach.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingPhantoms, ImagingAlgorithmsImage Processing, Computer-AssistedArtifactsHumansCalibrationReproducibility of ResultsBrain

Stichwörter der Autor:innen

gradient imperfectionsk‐space misalignmentrosette trajectorytrajectory estimation

Autor:innen und Institutionen

  • Central European Institute of Technology, Masaryk University, Brno, Czech Republic.
  • Institute of Scientific Instruments of the Czech Academy of Sciences, Brno, Czech Republic.
  • Department of Radiology, Masaryk Memorial Cancer Institute, Brno, Czech Republic.

ORCID-Profile: Peter Latta, Radovan Jiřík, Jiří Vitouš, Ondřej Macíček, Zenon Starčuk

Förderung

  • Ministry of Health of the Czech Republic
  • Ministry of Health of the Czech Republic - conceptual development of research organization
  • Czech Science Foundation
  • Ministry of Education, Youth and Sports
  • Ministerstvo Zdravotnictví Ceské Republiky
  • Grantová Agentura České Republiky

Zitieren

APA

Latta, P., Jiřík, R., Vitouš, J., Macíček, O., Vojtíšek, L., Rektor, I., Standara, M., Křístek, J., & Starčuk, Z. (2025). Two‐parametric prescan calibration of gradient‐induced sampling errors for rosette MRI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30355

Vancouver

Latta P, Jiřík R, Vitouš J, Macíček O, Vojtíšek L, Rektor I, et al. Two‐parametric prescan calibration of gradient‐induced sampling errors for rosette MRI. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30355

BibTeX
@article{Latta2025,
  author = {Latta, Peter and Jiřík, Radovan and Vitouš, Jiří and Macíček, Ondřej and Vojtíšek, Lubomír and Rektor, Ivan and Standara, Michal and Křístek, Jan and Starčuk, Zenon},
  title = {Two‐parametric prescan calibration of gradient‐induced sampling errors for rosette MRI},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30355}
}
Kostenlos starten →