High on sparsity: Interbin compensation of cardiac motion for improved assessment of left‐ventricular function using 5D whole‐heart MRI
Magnetic Resonance in Medicine · 2025-03 · 93 (3) · 975-992
DOI: 10.1002/mrm.30323 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 09.10.2024. Verfasst von Jérôme Yerly und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Vaud, Switzerland. Hauptthemen laut MEDLINE: Ventricular Function, Left, Heart, Algorithms, Magnetic Resonance Imaging. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Swiss National Science Foundation, Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung.
Abstract (Originalsprache)
Purpose
Cardiac magnetic resonance is the gold standard for evaluating left‐ventricular ejection fraction (LVEF). Standard protocols, however, can be inefficient, facing challenges due to significant operator and patient involvement. Although the free‐running framework (FRF) addresses these challenges, the potential of the extensive data it collects remains underutilized. Therefore, we propose to leverage the large amount of data collected by incorporating interbin cardiac motion compensation into FRF (FRF‐MC) to improve both image quality and LVEF measurement accuracy, while reducing the sensitivity to user‐defined regularization parameters.
Methods
FRF‐MC consists of several steps: data acquisition, self‐gating signal extraction, deformation field estimations, and motion‐resolved reconstruction with interbin cardiac motion compensation. FRF‐MC was compared with the original 5D‐FRF method using LVEF and several image‐quality metrics. The cardiac regularization weight () was optimized for both methods by maximizing image quality without compromising LVEF measurement accuracy. Evaluations were performed in numerical simulations and in 9 healthy participants. In vivo images were assessed by blinded expert reviewers and compared with reference standard 2D‐cine images.
Results
Both in silico and in vivo results revealed that FRF‐MC outperformed FRF in terms of image quality and LVEF accuracy. FRF‐MC reduced temporal blurring, preserving detailed anatomy even at higher cardiac regularization weights, and led to more accurate LVEF measurements. Optimized produced accurate LVEF for both methods compared with the 2D‐cine reference (FRF‐MC: 0.59% [−7.2%, 6.0%], p = 0.47; FRF: 0.86% [−8.5%, 6.7%], p = 0.36), but FRF‐MC resulted in superior image quality (FRF‐MC: 2.89 ± 0.58, FRF: 2.11 ± 0.47; p < 10 −3 ).
Conclusion
Incorporating interbin cardiac motion compensation significantly improved image quality, supported higher cardiac regularization weights without compromising LVEF measurement accuracy, and reduced sensitivity to user‐defined regularization parameters.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Vaud, Switzerland.
- Center for Biomedical Imaging (CIBM), Lausanne, Vaud, Switzerland.
- Research Institute, McGill University Health Center, Montréal, Québec, Canada.
- Department of Medicine and Radiology, McGill University Health Centre, Montréal, Québec, Canada.
ORCID-Profile: Jérôme Yerly, Christopher W Roy, Bastien Milani
Förderung
- Swiss National Science Foundation
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
Zitieren
APA
Yerly, J., Roy, C. W., Milani, B., Eyre, K., Raifee, M. J., & Stuber, M. (2025). High on sparsity: Interbin compensation of cardiac motion for improved assessment of left‐ventricular function using 5D whole‐heart MRI. Magnetic Resonance in Medicine, 93(3), 975-992. https://doi.org/10.1002/mrm.30323
Vancouver
Yerly J, Roy CW, Milani B, Eyre K, Raifee MJ, Stuber M. High on sparsity: Interbin compensation of cardiac motion for improved assessment of left‐ventricular function using 5D whole‐heart MRI. Magnetic Resonance in Medicine. 2025;93(3):975-992. doi:10.1002/mrm.30323
BibTeX
@article{Yerly2025,
author = {Yerly, Jérôme and Roy, Christopher W and Milani, Bastien and Eyre, Katerina and Raifee, Mozedin Javad and Stuber, Matthias},
title = {High on sparsity: Interbin compensation of cardiac motion for improved assessment of left‐ventricular function using 5D whole‐heart MRI},
journal = {Magnetic Resonance in Medicine},
year = {2025},
volume = {93},
number = {3},
pages = {975--992},
doi = {10.1002/mrm.30323}
}
EUVIMED