Accelerated cardiac cine with spatio‐coil regularized deep learning reconstruction
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30337 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Omer Burak Demirel und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine, Cardiovascular Division, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts, USA. Hauptthemen laut MEDLINE: Deep Learning, Magnetic Resonance Imaging, Cine, Algorithms, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 58 Literaturangaben. Gefördert von: NIH HHS, NHLBI NIH HHS, National Institutes of Health.
Abstract (Originalsprache)
Purpose
To develop an iterative deep learning (DL) reconstruction with spatio‐coil regularization and multichannel k‐space data consistency for accelerated cine imaging.
Methods
This study proposes a Spatio‐Coil Regularized DL (SCR‐DL) approach for iterative deep learning reconstruction incorporating multicoil information in data consistency and regularizer. SCR‐DL uses shift‐invariant convolutional kernels to interpolate missing k‐space lines and reconstruct individual coil images, followed by a regularizer that operates simultaneously across spatial and coil dimensions using learned image priors. At 8‐fold acceleration, SCR‐DL was compared with Generalized Autocalibrating Partially Parallel Acquisition (GRAPPA), sensitivity encoding (SENSE)‐based DL and spatio‐temporal regularized (STR)–DL reconstruction. In the retrospective undersampled cine, images were quantitatively evaluated using normalized mean square error (NMSE) and structural similarity index measure (SSIM). Additionally, agreement for left‐ventricular ejection fraction and left‐ventricular mass were assessed using prospectively accelerated cine images at 2‐fold and 8‐fold accelerations.
Results
The SCR‐DL algorithm successfully reconstructed highly accelerated cine images. SCR‐DL had significant improvements in NMSE (0.03 ± 0.02) and SSIM (91.4% ± 2.7%) compared with GRAPPA (NMSE: 0.09 ± 0.04, SSIM: 69.9% ± 11.1%; p < 0.001), SENSE‐DL (NMSE: 0.07 ± 0.04, SSIM: 86.9% ± 3.2%; p < 0.001), and STR‐DL (NMSE: 0.04 ± 0.03, SSIM: 90.0% ± 2.5%; p < 0.001) with retrospective undersampled cine. Despite the 3‐fold reduction in scan time, there was no difference between left‐ventricular ejection fraction (59.8 ± 4.5 vs. 60.8 ± 4.8, p = 0.46) or left‐ventricular mass (73.6 ± 19.4 g vs. 73.2 ± 19.7 g, p = 0.95) between R = 2 and R = 8 prospectively accelerated cine images.
Conclusions
SCR‐DL enabled highly accelerated cardiac cine imaging, significantly reducing breath‐hold time. Compared with GRAPPA or SENSE‐DL, images reconstructed with SCR‐DL showed superior NMSE and SSIM.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medicine, Cardiovascular Division, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts, USA.
ORCID-Profile: Omer Burak Demirel, Manuel Antonio Morales
Förderung
- NIH HHS
- NHLBI NIH HHS
- National Institutes of Health
Zitieren
APA
Demirel, O. B., Ghanbari, F., Morales, M. A., Pierce, P., Johnson, S., Rodriguez, J., Street, J. A., & Nezafat, R. (2025). Accelerated cardiac cine with spatio‐coil regularized deep learning reconstruction. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30337
Vancouver
Demirel OB, Ghanbari F, Morales MA, Pierce P, Johnson S, Rodriguez J, et al. Accelerated cardiac cine with spatio‐coil regularized deep learning reconstruction. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30337
BibTeX
@article{Demirel2025,
author = {Demirel, Omer Burak and Ghanbari, Fahime and Morales, Manuel Antonio and Pierce, Patrick and Johnson, Scott and Rodriguez, Jennifer and Street, Jordan Amy and Nezafat, Reza},
title = {Accelerated cardiac cine with spatio‐coil regularized deep learning reconstruction},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30337}
}