Reproducibility of tailored and universal nonselective excitation pulses at 7 T for human cardiac MRI : A 3‐year and an interday study
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30495 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Manuel Fernando Sánchez Alarcón und 5 weiteren Autor:innen. Beteiligte Einrichtung: Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany. Hauptthemen laut MEDLINE: Heart, Magnetic Resonance Imaging, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft, German Research Foundation.
Abstract (Originalsprache)
Purpose
Ultrahigh‐field (UHF; ≥7 T) MRI is challenging due to spatially heterogeneous B 1 + profiles. This longitudinal study evaluates the reproducibility of three parallel‐transmission excitation strategies to enable UHF cardiac MRI: vendor‐supplied radiofrequency (RF) shim, subject‐tailored kT‐points pulses (TPs), and universal kT‐points pulses (UPs).
Methods
Six healthy subjects underwent 7 T MRI scans performed by different MR operators using a 32‐element parallel‐transmission body array at four time points over 3 years. A single UP was computed and applied to all subjects. TPs were computed individually for each scan and organized into four configurations. Each configuration was applied to all scans from each subject to analyze intrasubject variability. Reproducibility was assessed by comparing the coefficient of variation (CV) of simulated flip angles (FAs) within the heart volume across scan sessions.
Results
TPs designed for a specific scan session yielded lower CVs (2‐fold reduction) than UP. Applying TPs to other scan sessions of the same subject, however, resulted in approximately 40% higher CVs and lower FA uniformity compared with the UP. On average, the UP consistently achieved the most reproducible results across inter‐year, inter‐day, and same‐operator studies, with CVs of approximately 12%.
Conclusion
Although TPs showed advantages when tailored for a specific target volume, they struggled with long‐term consistency and required lengthy calibration. The precomputed UP kT‐points pulses proved to be the most consistent across all scans acquired in the 3 years by different operators, minimizing CV‐data dispersion and maintaining FA uniformity.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany.
- Experimental and Clinical Research Center (ECRC), A Cooperation Between the Charité Medical Faculty and the Max-Delbrück Center for Molecular Medicine and HELIOS Hospital Berlin Buch, Berlin, Germany.
- German Center for Cardiovascular Research (DZHK), Partner Site Berlin, Berlin, Germany.
- Helios Clinics Berlin-Buch Department of Cardiology and Nephrology, Berlin, Germany.
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany.
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA.
ORCID-Profile: Jeanette Schulz-Menger, Sebastian Schmitter, Christoph Stefan Aigner
Förderung
- Deutsche Forschungsgemeinschaft
- German Research Foundation
Zitieren
APA
Sánchez Alarcón, M. F., Dietrich-Conzelmann, S., Bassenge, J. P., Schulz-Menger, J., Schmitter, S., & Aigner, C. S. (2025). Reproducibility of tailored and universal nonselective excitation pulses at 7 T for human cardiac MRI : A 3‐year and an interday study. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30495
Vancouver
Sánchez Alarcón MF, Dietrich-Conzelmann S, Bassenge JP, Schulz-Menger J, Schmitter S, Aigner CS. Reproducibility of tailored and universal nonselective excitation pulses at 7 T for human cardiac MRI : A 3‐year and an interday study. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30495
BibTeX
@article{SnchezAlarcn2025,
author = {Sánchez Alarcón, Manuel Fernando and Dietrich-Conzelmann, Sebastian and Bassenge, Jean Pierre and Schulz-Menger, Jeanette and Schmitter, Sebastian and Aigner, Christoph Stefan},
title = {Reproducibility of tailored and universal nonselective excitation pulses at 7 T for human cardiac MRI : A 3‐year and an interday study},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30495}
}
EUVIMED