Run‐time motion and first‐order shim control by expanded servo navigation
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30262 ↗At a glance
Journal article in Magnetic Resonance in Medicine, 2025. Written by Malte Riedel and 2 co-authors. Institution: Institute for Biomedical Engineering, ETH Zurich and University of Zurich, Switzerland. Major MEDLINE topics: Phantoms, Imaging, Brain, Magnetic Resonance Imaging, Algorithms. Cited 7 times so far (Crossref); 49 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: Horizon 2020 Framework Programme.
Abstract (original language)
Purpose
To provide a navigator‐based run‐time motion and first‐order field correction for three‐dimensional human brain imaging with high precision, minimal calibration and acquisition, and fast processing.
Methods
A complex‐valued linear perturbation model with feedback control is extended to estimate and correct for gradient shim fields using orbital navigators (2.3 ms). Two approaches for sensitizing the model to gradient fields are presented, one based on finite differences with three additional navigators, and another projection‐based approximation requiring no additional navigators. A mechanism for noise decorrelation of the matrix and the data is proposed and evaluated to reduce unwanted parameter biases.
Results
The rigid motion and first‐order field control achieves robust motion and gradient shim corrections improving image quality in a series of phantom and in vivo experiments with varying field conditions. In phantom scans, magnet drifts, forced gradient field perturbations and field distortions from shifts of a second bottle phantom are successfully corrected. Field estimates of the magnet drifts are in good agreement with concurrent field probe measurements. For in vivo scans, the proposed method mitigates field variations from torso motions while being robust to head motion. In vivo gradient field precisions were along with single‐digit micrometer and millidegree rigid precisions.
Conclusion
The navigator‐based method achieves accurate, high‐precision run‐time motion and field corrections with low sequence impact and calibration requirements.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Institute for Biomedical Engineering, ETH Zurich and University of Zurich, Switzerland.
ORCID profiles: Malte Riedel, Thomas Ulrich, Klaas P Pruessmann
Funding
- Horizon 2020 Framework Programme
Cite
APA
Riedel, M., Ulrich, T., & Pruessmann, K. P. (2025). Run‐time motion and first‐order shim control by expanded servo navigation. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30262
Vancouver
Riedel M, Ulrich T, Pruessmann KP. Run‐time motion and first‐order shim control by expanded servo navigation. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30262
BibTeX
@article{Riedel2025,
author = {Riedel, Malte and Ulrich, Thomas and Pruessmann, Klaas P},
title = {Run‐time motion and first‐order shim control by expanded servo navigation},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30262}
}